Performance characteristics of an excimer laser (XeCl) with single-stage magnetic pulse compression

被引:2
|
作者
Varshnay, N. K. [1 ]
Singh, A. [1 ]
Benerji, N. S. [1 ]
机构
[1] Raja Ramanna Ctr Adv Technol, Laser Mat Proc Div, Excimer Laser Sect, Indore 452013, Madhya Pradesh, India
来源
PRAMANA-JOURNAL OF PHYSICS | 2017年 / 88卷 / 02期
关键词
XeCl excimer laser; magnetic pulse compressor; saturable inductor; micro-machining; AUTOMATIC PREIONIZATION; DISCHARGE; WAFER;
D O I
10.1007/s12043-016-1334-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Performance characteristics of an excimer laser (XeCl) with single-stage magnetic pulse compression suitable for material processing applications are presented here. The laser incorporates in-built compact gas circulation and gas cooling to ensure fresh gas mixture between the electrodes for repetitive operation. A magnetically coupled tangential blower is used for gas circulation inside the laser chamber for repetitive operation. The exciter consists of C-C energy transfer circuit and thyratron is used as a high-voltage main switch with single-stage magnetic pulse compression (MPC) between thyratron and the laser electrodes. Low inductance of the laser head and uniform and intense pre-ionization are the main features of the electric circuit used in the laser. A 250 ns rise time voltage pulse was compressed to 100 ns duration with a single-stage magnetic pulse compressor using Ni-Zn ferrite cores. The laser can generate about 150 mJ at similar to 100 Hz rep-rate reliably from a discharge volume of 100 cm(3). 2D spatial laser beam profile generated is presented here. The profile shows that the laser beam is completely filled with flat-top which is suitable for material processing applications. The SEM image of the microhole generated on copper target is presented here.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Performance characteristics of an excimer laser (XeCl) with single-stage magnetic pulse compression
    N K VARSHNAY
    A SINGH
    N S BENERJI
    Pramana, 2017, 88
  • [2] 2-STAGE SHORTENING OF AN EXCIMER XECL LASER-PULSE BY MEANS OF SBS
    DZHIDZHOEV, MS
    KRAYUSHKIN, SV
    PLATONENKO, VT
    SLOBODCHIKOV, EV
    KVANTOVAYA ELEKTRONIKA, 1991, 18 (03): : 313 - 315
  • [3] ELECTRICAL EXCITATION OF AN XECL LASER USING MAGNETIC PULSE-COMPRESSION
    SMILANSKI, I
    BYRON, SR
    BURKES, TR
    APPLIED PHYSICS LETTERS, 1982, 40 (07) : 547 - 548
  • [4] FOLDED LONG PULSE XeCl EXCIMER LASER.
    Cao, Hongru
    Chen, Yongrong
    Che, Mingyu
    Hu, Xuejin
    Guangxue Xuebao/Acta Optica Sinica, 1987, 7 (05): : 410 - 414
  • [5] PULSE-PERIODIC EXCIMER LASER WITH THE MAGNETIC COMPRESSION CHAIN
    AGEEV, VP
    ATEZHEV, VV
    BUKREEV, VS
    VARTAPETOV, SK
    ZHUKOV, AN
    KONOV, VI
    SAVELEV, AD
    ZHURNAL TEKHNICHESKOI FIZIKI, 1986, 56 (07): : 1387 - 1389
  • [6] XeCl excimer laser with new prism resonator configurations and its performance characteristics
    Benerji, N. S.
    Singh, A.
    Varshnay, N.
    Singh, Bijendra
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (07):
  • [7] Beam divergency studies on a long pulse XeCl excimer laser
    Hofstra, RM
    Van Goor, FA
    Witteman, WJ
    OPTICAL RESONATORS: SCIENCE AND ENGINEERING, 1998, 45 : 253 - 266
  • [8] Beam divergence studies on a long pulse XeCl excimer laser
    Hofstra, RM
    vanGoor, FA
    Witteman, WJ
    HIGH-POWER LASERS: GAS AND SOLID STATE LASERS, 1996, 1788 : 116 - 126
  • [9] SHORT-PULSE GENERATION FROM XECL EXCIMER LASER
    CHRISTOV, CG
    CHALTAKOV, IV
    LYUTSKANOV, VL
    TOMOV, IV
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (08): : 714 - 715
  • [10] Characteristics of XeCl excimer-laser annealed insulator
    Jang, KH
    Choi, HS
    Jun, JH
    Yoo, JS
    Han, MK
    AMORPHOUS SILICON TECHNOLOGY - 1996, 1996, 420 : 105 - 108