Potentiometric enzyme immunoassay using miniaturized anion-selective electrodes for detection

被引:25
|
作者
Szucs, Julia [1 ]
Pretsch, Ernoe [2 ]
Gyurcsanyi, Robert E. [1 ,3 ]
机构
[1] Budapest Univ Technol & Econ, Dept Inorgan & Analyt Chem, H-1111 Budapest, Hungary
[2] Swiss Fed Inst Technol, Inst Biogeochem & Pollutant Dynam, CH-8092 Zurich, Switzerland
[3] Hungarian Acad Sci, Res Grp Tech Analyt Chem, H-1111 Budapest, Hungary
基金
美国国家卫生研究院;
关键词
HUMAN IMMUNOGLOBULIN-G; ALKALINE-PHOSPHATASE; ANTIGEN; LABELS; ASSAYS; ACID;
D O I
10.1039/b904321g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzyme-linked immunosorbent assay (ELISA) for prostate specific antigen (PSA) detection in human serum was developed based on the potentiometric detection of 6,8-difluoro-4-methylumbelliferone (DiFMU). The assays were carried out in anti-human PSA capture antibody modified microtiter plates (150 mu L volume). After incubation in the PSA-containing serum samples, beta-galactosidase-labeled PSA tracer antibody was added. The beta-galactosidase label catalyzed the hydrolysis of 6,8-difluoro-4-methylumbelliferyl-beta-D-galactopyranoside (DiFMUG) and the resulting DiFMU(-) anion was detected by potentiometric microelectrodes with anion-exchanger membrane. The selectivity of the anion-exchanger electrode is governed by the lipophilicity of the anions in the sample. Since DiFMU(-) is much more lipophilic (log P = 1.83) than any of the inorganic anions normally present in the working buffers and occurs in its anionic form at the physiological pH (pK(a) = 4.19), it was chosen as the species to be detected. The potentiometric ELISA-based method detects PSA in serum with a linear concentration range of 0.1-50 ng/mL. These results confirm the applicability of potentiometric detection in diagnostic PSA assays. Owing to simple methodology and low cost, potentiometric immunoassays seem to offer a feasible alternative to the development of in vitro diagnostic platforms.
引用
收藏
页码:1601 / 1607
页数:7
相关论文
共 50 条
  • [1] The potentiometric behavior of polymer supported metalloporphyrins as anion-selective electrodes
    Oh, KC
    Lim, SM
    Paeng, IR
    Paeng, KJ
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 506 (01): : 42 - 47
  • [2] A Potentiometric Multisensor System of Anion-Selective Electrodes Based on Ionic Liquids
    Shvedene N.V.
    Rzhevskaia A.V.
    Aksenova V.A.
    Pletnev I.V.
    Moscow University Chemistry Bulletin, 2017, 72 (6) : 307 - 314
  • [3] On the origin of the Hofmeister effect in anion-selective potentiometric electrodes with tetraalkylammonium salts
    Wojciechowski, Kamil
    Kucharek, Marta
    Wroblewski, Wojciech
    Warszynski, Piotr
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 638 (02) : 204 - 211
  • [4] The potentiometric behavior of polymer-supported metallophthalocyanines used as anion-selective electrodes
    M. Arvand
    A. Pourhabib
    R. Shemshadi
    M. Giahi
    Analytical and Bioanalytical Chemistry, 2007, 387 : 1033 - 1039
  • [5] The potentiometric behavior of polymer-supported metallophthalocyanines used as anion-selective electrodes
    Arvand, M.
    Pourhabib, A.
    Shemshadi, R.
    Giahi, M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (03) : 1033 - 1039
  • [6] Potentiometric detection of carboxylic acids, phosphate esters, and nucleotides in liquid chromatography using anion-selective coated-wire electrodes
    Picioreanu, S
    Poels, I
    Frank, J
    van Dam, JC
    van Dedem, GWK
    Nagels, LJ
    ANALYTICAL CHEMISTRY, 2000, 72 (09) : 2029 - 2034
  • [7] NEW ANION-SELECTIVE AND GAS-SELECTIVE POTENTIOMETRIC SENSORS
    MEYERHOFF, ME
    PRANITIS, DM
    YIM, HS
    CHANIOTAKIS, NA
    PARK, SB
    ACS SYMPOSIUM SERIES, 1989, 403 : 26 - 45
  • [8] ANION-SELECTIVE ELECTRODES BASED ON DIAMMONIUM IONOPHORES
    WOTRING, VJ
    BACHAS, LG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 254 - ANYL
  • [9] Influence of pH on anion exchange and the properties of anion-selective electrodes
    Gulevich, AL
    Rakhman'ko, EM
    Podterob, AP
    ZHURNAL FIZICHESKOI KHIMII, 1998, 72 (05): : 846 - 850
  • [10] SELECTIVITY STUDIES ON ANION-SELECTIVE MEMBRANE ELECTRODES
    BACK, S
    ANALYTICAL CHEMISTRY, 1972, 44 (09) : 1696 - &