A chip-based amide-HILIC LC/MS platform for glycosaminoglycan glycomics profiling

被引:79
|
作者
Staples, Gregory O. [1 ]
Bowman, Michael J. [1 ]
Costello, Catherine E. [1 ]
Hitchcock, Alicia M. [1 ]
Lau, James M. [2 ]
Leymarie, Nancy [1 ]
Miller, Christine [2 ]
Naimy, Hicham [1 ]
Shi, Xiaofeng [1 ]
Zaia, Joseph [1 ]
机构
[1] Boston Univ, Sch Med, Dept Biochem, Boston, MA 02118 USA
[2] Agilent Technol Corp, Santa Clara, CA USA
关键词
Carbohydrates; Complex mixture identification; Glycomics; Electrospray ionization-quadrupole time of flight tandem mass spectrometry; TANDEM MASS-SPECTROMETRY; LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY; CHONDROITIN SULFATE OLIGOSACCHARIDES; CARBOHYDRATE ELECTROPHORESIS FACE; HEPARAN-SULFATE; ENZYMATIC RECONSTRUCTION; COMPOSITIONAL ANALYSIS; MOLECULAR DIVERSITY; DERMATAN SULFATE; DOMAIN-STRUCTURE;
D O I
10.1002/pmic.200701008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A key challenge to investigations into the functional roles of glycosaminoglycans (GAGS) in biological systems is the difficulty in achieving sensitive, stable, and reproducible mass spectrometric analysis. GAGS are linear carbohydrates with domains that vary in the extent of sulfation, acetylation, and uronic acid epimerization. It is of particular importance to determine spatial and temporal variations of GAG domain structures in biological tissues. In order to analyze GAGS from tissue, it is useful to couple MS with an on-line separation system. The purposes of the separation system are both to remove components that inhibit GAG ionization and to enable the analysis of very complex mixtures. This contribution presents amide-silica hydrophilic interaction chromatography (HILIC) in a chip-based format for LC/MS of heparin, heparan sulfate (HS) GAGs. The chip interface yields robust performance in the negative ion mode that is essential for GAGS and other acidic glycan classes while the built-in trapping cartridge reduces background from the biological tissue matrix. The HILIC chromatographic separation is based on a combination of the glycan chain lengths and the numbers of hydrophobic acetate (Ac) groups and acidic sulfate groups. In summary, chip based amide-HILIC LC/MS is an enabling technology for GAG glycomics profiling.
引用
收藏
页码:686 / 695
页数:10
相关论文
共 50 条
  • [1] Chip-based LC/MS system from Agilent
    Henry, CM
    Thayer, AM
    CHEMICAL & ENGINEERING NEWS, 2005, 83 (11) : 36 - 36
  • [2] A Miniaturized Chip-based ODNP Platform
    Yang, Qing
    Lotfi, Hadi
    Dreyer, Frederik
    Kern, Michal
    Anders, Jens
    2024 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, ISCAS 2024, 2024,
  • [3] Chip-based MS is readily deployable
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 46 : IX - IX
  • [4] A comparison of LC/MS and LC fraction analysis by chip-based nanoelectrospray MS in the identification of ibuprofen metabolites from human urine
    Van Pelt, CK
    Hao, ZQ
    Campbell, D
    Henion, J
    Williams, G
    DRUG METABOLISM REVIEWS, 2004, 36 : 49 - 49
  • [5] GlycReSoft: A software tool for processing glycomics and glycopeptidomics LC/MS profiling data
    Tan, Yan
    Maxwell, Evan
    Tan, Yuxiang
    Hu, Han
    Benson, Gary
    Aizikov, Konstantin
    Conley, Shannon
    Staples, Gregory
    Slysz, Gordon
    Smith, Richard
    Zaia, Joseph
    GLYCOBIOLOGY, 2012, 22 (11) : 1616 - 1617
  • [6] Quantitation of mutagenic impurities in APIs using a platform chip-based CE–MS method
    Bao, Jiemin
    Blue, Laura E.
    Flick, Tawnya
    Lee, Burton
    Yan, Helen
    Mellors, J. Scott
    Pharmaceutical Technology, 2019, 43 (08) : 32 - 35
  • [7] Bioinformatics platform for chip-based DNA sequencing
    Zhang, Yiming
    Jiang, Peng
    Tong, Jing
    Wang, Shaonan
    Da, Yao
    Lu, Zuhong
    PROGRESS ON POST-GENOME TECHNOLOGIES, 2006, : 358 - 360
  • [8] Chip-based analysis of protein-protein interactions by fluorescence detection and on-chip immunoprecipitation combined with μLC-MS/MS analysis
    Sydor, JR
    Scalf, M
    Sideris, S
    Mao, GD
    Pandey, Y
    Tan, M
    Mariano, M
    Moran, MF
    Nock, S
    Wagner, P
    ANALYTICAL CHEMISTRY, 2003, 75 (22) : 6163 - 6170
  • [9] Serum Glycomics Profiling of Patients with Primary Restless Legs Syndrome Using LC-MS/MS
    Dong, Xue
    Mondello, Stefania
    Kobeissy, Firas
    Ferri, Raffaele
    Mechref, Yehia
    JOURNAL OF PROTEOME RESEARCH, 2020, 19 (08) : 2933 - 2941
  • [10] A Versatile Platform for Comprehensive Chip-Based Explorative Cytometry
    Hennig, Christian
    Adams, Nico
    Hansen, Gesine
    CYTOMETRY PART A, 2009, 75A (04) : 362 - 370