High heat flux test of CVD-tungsten coated Cu heat sink divertor mock-up

被引:11
|
作者
Sato, K
Nakamura, K
Suzuki, S
Araki, M
Dairaku, M
Yokoyama, K
Akiba, M
机构
来源
FUSION TECHNOLOGY | 1996年 / 30卷 / 03期
关键词
D O I
10.13182/FST96-A11963028
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
CVD-tungsten coated divertor mock-ups were fabricated and tested in an ion beam test facility in JAERI. The mock-up consisted of a 2 mm thick CVD-tungsten on a 30 wt% Cu infiltrated tungsten skeleton heat sink, For the thermal fatigue tests, the heat load of 15 MW/m(2), 0.3 s was applied to simulate the bonding interface temperature under a steady heat load of 5 MW/m(2). The mock-up successfully endured a heat load of 15 MW/m(2), 0.3 s for more than 1000 thermal cycles. No cracks were observed at the bonding interface by optical microscope observation. Screening tests were also performed to evaluate the performance limit of the mock-up. The mock-up endured up to a heat load of 20 MW/m(2), 10 s without failure.
引用
收藏
页码:769 / 773
页数:5
相关论文
共 50 条
  • [1] High heat flux experiments on a saddle shaped divertor mock-up
    Suzuki, S
    Araki, M
    Sato, K
    Nakamura, K
    Akiba, M
    [J]. FUSION ENERGY 1996, VOL 3, 1997, : 565 - 570
  • [2] Simulating cyclic high heat flux loading of divertor cooling finger mock-up
    Kosmrlj, Samo
    Koncar, Bostjan
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2013, 261 : 317 - 325
  • [3] High heat flux performance of brazed tungsten macro-brush test mock-up for divertors
    Patil, Yashashri
    Khirwadkar, S. S.
    Krishnan, D.
    Patel, A.
    Tripathi, S.
    Singh, K. P.
    Belsare, S. M.
    [J]. JOURNAL OF NUCLEAR MATERIALS, 2013, 437 (1-3) : 326 - 331
  • [4] High heat flux test of actively cooled tungsten-coated carbon divertor mock-ups
    Tokunaga, K
    Yoshida, N
    Kubota, Y
    Noda, N
    Imamura, Y
    Oku, T
    Kurumada, A
    Sogabe, T
    Kato, T
    Plöchl, L
    [J]. FUSION ENGINEERING AND DESIGN, 2000, 49-50 : 371 - 376
  • [5] Microchannel cooling technique for dissipating high heat flux on W/Cu flat-type mock-up for EAST divertor
    Lu, Mingxiang
    Han, Le
    Zhao, Qi
    Qiu, Juncheng
    Zhou, Jianhong
    Hu, Dinghua
    Mou, Nanyu
    Chen, Xuemei
    [J]. PLASMA SCIENCE & TECHNOLOGY, 2022, 24 (09)
  • [6] High heat flux test of tungsten brazed mock-ups developed for KSTAR divertor
    Song, J. H.
    Kim, K. M.
    Hong, S. H.
    Kim, H. T.
    Park, S. H.
    Park, H. K.
    Ahn, H. J.
    Kim, S. K.
    Lee, D. W.
    [J]. FUSION ENGINEERING AND DESIGN, 2016, 109 : 78 - 81
  • [7] Microchannel cooling technique for dissipating high heat flux on W/Cu flat-type mock-up for EAST divertor
    鲁铭翔
    韩乐
    赵起
    邱俊城
    周剑宏
    胡定华
    牟南瑜
    陈雪梅
    [J]. Plasma Science and Technology, 2022, (09) : 138 - 148
  • [8] Ultrasonic analysis of tungsten monoblock divertor mock-ups after high heat flux test
    Dose, Giacomo
    Roccella, Selanna
    Richou, Marianne
    Gallay, Franklin
    Visca, Eliseo
    Greuner, Henri
    Romanelli, Francesco
    Hunger, Katja
    Barrett, Tom
    You, Jeong-Ha
    [J]. FUSION ENGINEERING AND DESIGN, 2019, 146 : 870 - 873
  • [9] High heat flux testing of mock-ups for a full tungsten ITER divertor
    Gavila, P.
    Riccardi, B.
    Constans, S.
    Jouvelot, J. L.
    Vastra, I. Bobin
    Missirlian, M.
    Richou, M.
    [J]. FUSION ENGINEERING AND DESIGN, 2011, 86 (9-11) : 1652 - 1655
  • [10] A method for high heat flux fatigue test of W/Cu/steel small mock-up using normal cooling conditions
    Wang, Ji-Chao
    Wang, Wanjing
    Li, Qiang
    Qin, Sigui
    Lei, Mingzhun
    Luo, Guang-Nan
    [J]. NUCLEAR MATERIALS AND ENERGY, 2021, 28