Coronary risk assessment at X-ray dose equivalent ungated chest CT: Results of a multi-reader study

被引:7
|
作者
Messerli, Michael [1 ,2 ]
Hechelhammer, Lukas [1 ]
Leschka, Sebastian [1 ,3 ]
Warschkow, Rene [4 ]
Wildermuth, Simon [1 ]
Bauer, Ralf W. [1 ]
机构
[1] Cantonal Hosp St Gallen, Div Radiol & Nucl Med, St Gallen, Switzerland
[2] Univ Zurich, Univ Hosp Zurich, Dept Nucl Med, Zurich, Switzerland
[3] Univ Zurich, Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Zurich, Switzerland
[4] Cantonal Hosp St Gallen, Dept Surg, St Gallen, Switzerland
关键词
Computed tomography; Ultra-low dose; Coronary artery disease; Coronary artery calcium; Iterative reconstruction; Tin filtration; STANDARD AGATSTON SCORE; LUNG SCREENING TRIAL; COMPUTED-TOMOGRAPHY; ARTERY CALCIUM; CARDIAC CT; CANCER; CALCIFICATION; SCANS; QUANTIFICATION; GUIDELINES;
D O I
10.1016/j.clinimag.2017.10.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To determine the value of ultra-low dose chest CT with tin filtration for ordinal coronary artery calcium (CAC) risk scoring. Methods: 50 patients were prospectively included and underwent clinical standard dose chest CT (1.8 +/- 0.7 mSv) and ultra-low dose CT (0.13 +/- 0.01 mSv). Four radiologists estimated presence and extent of CAC. Results: Weighted kappa values for CAC were 0.76-0.97 in standard dose and 0.75-0.95 in ultra-low dose CT (p < 0.001). Good to excellent agreement was observed for CAC ordinal risk assessment, with readers reporting identical risk in 81% of cases. Conclusion: CAC risk can be qualitatively assessed from X-ray dose equivalent ungated chest CT.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 50 条
  • [1] Chest X-ray Dose Equivalent Low -dose CT with Tin Filtration: Potential Role for the Assessment of Pectus Excavatum
    Messerli-Odermatt, Olivia
    Serrallach, Bettina
    Gubser, Manuel
    Leschka, Sebastian
    Bauer, Ralf W.
    Dubois, Josee
    Alkadhi, Hatem
    Wildermuth, Simon
    Waelti, Stephan L.
    [J]. ACADEMIC RADIOLOGY, 2020, 27 (05) : 644 - 650
  • [2] Ultralow dose CT for pulmonary nodule detection with chest x-ray equivalent dose – a prospective intra-individual comparative study
    Michael Messerli
    Thomas Kluckert
    Meinhard Knitel
    Stephan Wälti
    Lotus Desbiolles
    Fabian Rengier
    René Warschkow
    Ralf W. Bauer
    Hatem Alkadhi
    Sebastian Leschka
    Simon Wildermuth
    [J]. European Radiology, 2017, 27 : 3290 - 3299
  • [3] Ultralow dose CT for pulmonary nodule detection with chest x-ray equivalent dose - a prospective intra-individual comparative study
    Messerli, Michael
    Kluckert, Thomas
    Knitel, Meinhard
    Walti, Stephan
    Desbiolles, Lotus
    Rengier, Fabian
    Warschkow, Rene
    Bauer, Ralf W.
    Alkadhi, Hatem
    Leschka, Sebastian
    Wildermuth, Simon
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (08) : 3290 - 3299
  • [4] Pneumonia Detection in Chest X-Ray Dose-Equivalent CT: Impact of Dose Reduction on Detectability by Artificial Intelligence
    Schwyzer, Moritz
    Martini, Katharina
    Skawran, Stephan
    Messerli, Michael
    Frauenfelder, Thomas
    [J]. ACADEMIC RADIOLOGY, 2021, 28 (08) : 1043 - 1047
  • [5] Leveraging Deep Learning Decision-Support System in Specialized Oncology Center: A Multi-Reader Retrospective Study on Detection of Pulmonary Lesions in Chest X-ray Images
    Kvak, Daniel
    Chromcova, Anna
    Hruby, Robert
    Janu, Eva
    Biros, Marek
    Pajdakovic, Marija
    Kvakova, Karolina
    Al-antari, Mugahed A.
    Polaskova, Pavlina
    Strukov, Sergei
    [J]. DIAGNOSTICS, 2023, 13 (06)
  • [6] Evaluation of the impact of artificial intelligence-assisted image interpretation on the diagnostic performance of clinicians in identifying pneumothoraces on plain chest X-ray: a multi-case multi-reader study
    Novak, Alex
    Ather, Sarim
    Gill, Avneet
    Aylward, Peter
    Maskell, Giles
    Cowell, Gordon W.
    Morgado, Abdala Trinidad Espinosa
    Duggan, Tom
    Keevil, Melissa
    Gordon, Oliva
    Akrama, Osama
    Belcher, Elizabeth
    Taberham, Rhona
    Hallifax, Rob
    Bahra, Jasdeep
    Banerji, Abhishek
    Bailey, Jon
    James, Antonia
    Ansaripour, Ali
    Spence, Nathan
    Wrightson, John
    Jarral, Waqas
    Barry, Steven
    Bhatti, Saher
    Astley, Kerry
    Shadmaan, Amied
    Ghelman, Sharon
    Baenen, Alec
    Oke, Jason
    Bloomfield, Claire
    Beggs, Mark
    Gleeson, Fergus
    [J]. EMERGENCY MEDICINE JOURNAL, 2024,
  • [7] Preliminary results of a small X-ray irradiator for equivalent dose estimation
    D. G. Hong
    T. Yawata
    T. Hashimoto
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2007, 273 : 353 - 356
  • [8] Preliminary results of a small X-ray irradiator for equivalent dose estimation
    Hong, D. G.
    Yawata, T.
    Hashimoto, T.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 273 (02) : 353 - 356
  • [9] Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13 mSv
    Messerli, Michael
    Kluckert, Thomas
    Knitel, Meinhard
    Rengier, Fabian
    Warschkow, Rene
    Alkadhi, Hatem
    Leschka, Sebastian
    Wildermuth, Simon
    Bauer, Ralf W.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (12) : 2217 - 2224
  • [10] Diagnostic accuracy of chest X-ray dose-equivalent CT for assessing calcified atherosclerotic burden of the thoracic aorta
    Messerli, Michael
    Giannopoulos, Andreas A.
    Leschka, Sebastian
    Warschkow, Rene
    Wildermuth, Simon
    Hechelhamer, Lukas
    Bauer, Ralf W.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1080):