Performance analysis of heat transfer rate and negative air ion application for passive thermosiphon beam system

被引:0
|
作者
Ji Ke [1 ]
Cai Wenjian [1 ]
Wu Bingjie [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore, Singapore
关键词
passive thermosiphon beam; heat transfer rate; thermal comfort; indoor air quality; DISPLACEMENT VENTILATION; THERMAL COMFORT; DESIGN;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the performance of passive thermosiphon beam (PTB) under various operation conditions. In addition, the application of negative ion generator in PTB system is investigated. The three factors (chilled water flow rate, average temperature difference and fall duct length) that influence the PTB heat transfer rate are tested separately in a thermal isolated room. Meanwhile, the comparison study of negative air ion concentration in different positions and working conditions is demonstrated. The study shows that the heat transfer rate of PTB unit can be improved by adjust the chilled water flow rate and average temperature difference. The utilize of fall duct can enhance displacement ventilation and negative ion generator is a feasible option in the PTB system.
引用
收藏
页码:1609 / 1614
页数:6
相关论文
共 50 条
  • [1] Analysis of the heat transfer capacity of passive containment air cooling system
    Feng Y.
    Wang H.
    Ma Y.
    Li Y.
    Guo Q.
    Yu M.
    Liu Z.
    Han X.
    Yuan Y.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2023, 44 (07): : 1162 - 1168
  • [2] ANALYSIS OF THE EFFECTIVENESS OF A THERMOSIPHON SYSTEM IN RECOVERY OF THE HEAT OF EXHAUST AIR.
    Fert, A.R.
    Chekhovskaya, N.I.
    Grebenyuk, A.V.
    Heat transfer. Soviet research, 1988, 20 (01): : 112 - 118
  • [3] Analysis of Heat Transfer Performance Impact for Passive Containment Air-Cooling System Radiation Plates
    Wang, Hongliang
    Feng, Yu
    Yu, Mingrui
    Guo, Yong
    Li, Wei
    Guo, Qiang
    Yuan, Yidan
    ENERGIES, 2025, 18 (02)
  • [4] Influence of extreme weather conditions on the heat transfer performance of a passive containment air cooling system
    Wang H.
    Feng Y.
    Li Y.
    Ma Y.
    Yu M.
    Liu Z.
    Han X.
    Guo Q.
    Yuan Y.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2023, 44 (07): : 1169 - 1174
  • [5] Zonal air exchange rate of a passive solar house and resultant sensible air heat transfer
    Overen, Ochuko Kelvin
    Meyer, Edson Leroy
    Makaka, Golden
    Ziuku, Sosten
    Mamphweli, Sampson
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (07) : 914 - 926
  • [6] Heat transfer analysis for the design and application of the passive cooling rate controlled device-Box-in-box
    Zhou, Xiaoming
    Shu, Zhiaquan
    Ding, Weiping
    Heimfeld, Shelly
    Chung, JaeHyun
    Du, Pingan
    Liu, Carolyn
    Gao, Dayong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (9-10) : 2136 - 2143
  • [7] Instrumentation and application of the ion beam analysis line of the in situ ion beam system
    黄志宏
    张早娣
    王泽松
    王浪平
    付德君
    Nuclear Science and Techniques, 2015, 26 (01) : 23 - 27
  • [8] Instrumentation and application of the ion beam analysis line of the in situ ion beam system
    Huang Zhi-Hong
    Zhang Zao-Di
    Wang Ze-Song
    Wang Lang-Ping
    Fu De-Jun
    NUCLEAR SCIENCE AND TECHNIQUES, 2015, 26 (01) : 23 - 28
  • [9] Passive enhancement of heat transfer in a microchannel by an adjoint system of cylinder and flexible beam
    Xin, Zhiqiang
    Chen, Jing
    Gu, Shuitao
    Li, Ke
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2022, 82 (12) : 765 - 787
  • [10] Analysis on the Factors of Heat Transfer Rate and Air Volume in Tunnel
    Du, Cuifeng
    Bian, Menglong
    2017 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL AND ENERGY ENGINEERING (IC3E 2017), 2017, 63