Clinical evaluation of the reproducibility of volume measurements of pulmonary nodules

被引:5
|
作者
Wormanns, D [1 ]
Kohl, G [1 ]
Klotz, E [1 ]
Heindel, W [1 ]
Diederich, S [1 ]
机构
[1] Univ Munster, Dept Clin Radiol, D-48129 Munster, Germany
关键词
computed tomography; pulmonary nodule; volumetric measurement;
D O I
10.1117/12.467172
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High reproducibility of volumetric measurements is an important prerequisite for follow-up of small lung nodules in order to differentiate malignant from benign lesions in a lung cancer screening setting. This study was aimed to evaluate the measurement reproducibility of a new software tool for pulmonary nodule volumetry. In an ongoing study, 147 pulmonary nodules (size 1.6-17.5 mm) were examined with low-dose multidetector CT (Siemens Somatom Volume Zoom, 120 kVp, 20 mAs, detector collimation 4x1 mm, normalized pitch 1.75, slice thickness 1.25 mm, reconstruction increment 0.8 mm). Two consecutive low-dose scans covering the whole lung volume were performed within a few minutes. Between both scans, patients were asked to leave the CT scanner, and the second scan was planned independently from the first one. For all visually detected pulmonary nodules with a diameter <20 mm nodule volume was determined on both scans using a software prototype containing segmentation and volumetry algorithms. Results from both scans were compared. Nodule volume differences were determined as difference between the first and second measurement and ranged from -87 to 125%. The performance of the diagnostic test was measured using ROC analysis. For the detection of a volume doubling the area under curve (A(Z)) was 0.98, for a growth of 50% the A(Z) was 0.89. Further refinement of the segmentation algorithm should lead to more consistent measurements in ill-defined nodules. In conclusion, volumetric measurement of pulmonary nodules in multislice CT data sets is a reliable tool for the detection of growth in small pulmonary nodules.
引用
收藏
页码:316 / 322
页数:7
相关论文
共 50 条
  • [1] Segmentation of pulmonary nodules: Influence of scanning and reconstruction parameters on reproducibility of volume measurements
    Kohl, G
    Schoepf, UO
    Naidich, DP
    Schaller, S
    RADIOLOGY, 2001, 221 : 461 - 461
  • [2] Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
    Dag Wormanns
    Gerhard Kohl
    Ernst Klotz
    Anke Marheine
    Florian Beyer
    Walter Heindel
    Stefan Diederich
    European Radiology, 2004, 14 : 86 - 92
  • [3] Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
    Wormanns, D
    Kohl, G
    Klotz, E
    Marheine, A
    Beyer, F
    Heindel, W
    Diederich, S
    EUROPEAN RADIOLOGY, 2004, 14 (01) : 86 - 92
  • [4] Reproducibility of lung volume measurements
    Hankinson, JL
    Stocks, J
    Peslin, R
    EUROPEAN RESPIRATORY JOURNAL, 1998, 11 (03) : 787 - 790
  • [5] Imaging features and clinical evaluation of pulmonary nodules in children
    Dilimulati, Muheremu
    Yuan, Shuhua
    Jiang, Hejun
    Wang, Yahua
    Ma, Hui
    Shen, Shiyu
    Lin, Jilei
    Chen, Jiande
    Yin, Yong
    FRONTIERS IN ONCOLOGY, 2024, 14
  • [6] Reproducibility of measurements of cerebral infarct volume
    van der Worp, HB
    Claus, SS
    Baer, PRD
    Ramos, LMP
    Algra, A
    van Gijn, J
    Kappelle, LJ
    STROKE, 2000, 31 (01) : 335 - 335
  • [7] Evaluation of Pulmonary Nodules Clinical Practice Consensus Guidelines for Asia
    Bai, Chunxue
    Choi, Chang-Min
    Chu, Chung Ming
    Anantham, Devanand
    Ho, James Chung-man
    Khan, Ali Zamir
    Lee, Jang-Ming
    Li, Shi Yue
    Saenghirunvattana, Sawang
    Yim, Anthony
    CHEST, 2016, 150 (04) : 877 - 893
  • [8] Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements
    Gietema, Hester A.
    Wang, Ying
    Xu, Dongming
    van Klaveren, Rob J.
    deKoning, Harry
    Scholten, Ernst
    Verschakelen, Johny
    Kohl, Gerhard
    Oudkerk, Matthijs
    Prokop, Mathias
    RADIOLOGY, 2006, 241 (01) : 251 - 257
  • [9] Influence of Bag Volume on Reproducibility of Inert Gas Rebreathing Pulmonary Blood Flow Measurements in Patients with Pulmonary Diseases
    Saur, Joachim
    Kraus, Franziska
    Brade, Joachim
    Haghi, Dariusch
    Behnes, Michael
    Hoffmann, Ursula
    Borggrefe, Martin
    Kaden, Jens J.
    Trinkmann, Frederik
    LUNG, 2013, 191 (05) : 467 - 473
  • [10] Influence of Bag Volume on Reproducibility of Inert Gas Rebreathing Pulmonary Blood Flow Measurements in Patients with Pulmonary Diseases
    Joachim Saur
    Franziska Kraus
    Joachim Brade
    Dariusch Haghi
    Michael Behnes
    Ursula Hoffmann
    Martin Borggrefe
    Jens J. Kaden
    Frederik Trinkmann
    Lung, 2013, 191 : 467 - 473