Heat transfer to the ceiling of the riser of a circulating fluidized bed

被引:2
|
作者
Zhang, Rui
Dutta, Animesh [1 ]
Basu, Prabir
机构
[1] Asian Inst Technol, Energy Field Study, Klongluang 12120, Pathumthani, Thailand
[2] Greenfield Res Inc, Halifax, NS B3M 1N8, Canada
[3] Dalhousie Univ, Dept Engn Mech, Halifax, NS B3J 2X4, Canada
关键词
circulating fluidized bed boiler; ceiling; heat transfer; circulation rates;
D O I
10.1016/j.ces.2006.04.022
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Very little information on the heat transfer to the ceiling of a circulating fluidized bed (CFB) boiler is available in the published literature though it constitutes a significant part of the furnace heat absorption. So, to explore this less-known heat transfer process a series of experiments were conducted at four different superficial gas velocities and three external solids circulation rates in a CFB pilot plant with a riser having a height of 5 m and a cross section of 1.0 m x 0.5 m. The experimental results suggest that both solids circulation rates and superficial gas velocities had a significant influence on the local heat transfer to the ceiling close to the riser exit to the gas solids separator. However, on the ceiling, opposite of the exit, solids circulation rates and superficial gas velocities had only a minor influence on the local heat transfer coefficients. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5907 / 5911
页数:5
相关论文
共 50 条
  • [1] An experimental investigation on heat transfer to the ceiling of the riser of circulating fluidized bed
    Zhang, R
    Dutta, A
    Basu, P
    Circulating Fluidized Bed Technology VIII, 2005, : 246 - 253
  • [2] Axial heat transfer correlations in a circulating fluidized bed riser
    Sundaresan, R.
    Kolar, Ajit Kumar
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 985 - 996
  • [3] Heat transfer characteristics at an axial tube in a circulating fluidized bed riser
    Kolar, AK
    Sundaresan, R
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (07) : 673 - 681
  • [4] Heat transfer in the downer and the riser of a circulating fluidized bed - A comparative study
    Ma, YL
    Zhu, J
    CHEMICAL ENGINEERING & TECHNOLOGY, 2001, 24 (01) : 85 - 90
  • [5] Heat transfer in the downer and the riser of a circulating fluidized bed - a comparative study
    Ma, Ying L.
    Zhu, Jesse
    Chemical Engineering and Technology, 2001, 24 (01): : 85 - 90
  • [6] Effect of riser exit geometry on bed hydrodynamics and heat transfer in a circulating fluidized bed riser column
    Reddy, BV
    Nag, PK
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2001, 25 (01) : 1 - 8
  • [7] Study of wall-to-bed heat transfer in circulating fluidized bed riser based on CFD simulation
    Wanchan, Waritnan
    Khongprom, Parinya
    Limtrakul, Sunun
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2020, 156 : 442 - 455
  • [8] Heat transfer in a circulating fluidized bed
    Yu S. Teplitskii
    Journal of Engineering Physics and Thermophysics, 1998, 71 (3) : 443 - 449
  • [9] Parametric study on the hydrodynamics and heat transfer along the riser of a pressurized circulating fluidized bed unit
    Kalita, P.
    Saha, U. K.
    Mahanta, P.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 44 : 620 - 630
  • [10] Heat transfer in circulating fluidized bed boilers
    Breitholtz, Claes
    Doktorsavhandlingar vid Chalmers Tekniska Hogskola, 2000, (1580): : 1 - 29