Vibration displacement immunization model for measuring the free spectral range by means of a laser self-mixing velocimeter

被引:6
|
作者
Zhao, Yunkun [1 ,3 ]
Xu, Guanting [1 ]
Zhang, Chen [1 ]
Liu, Keyan [1 ]
Lu, Liang [1 ,2 ]
机构
[1] Anhui Univ, Minist Educ, Key Lab Optoelect Informat Acquisit & Manipulat, Jiulong Rd 111, Hefei 230601, Anhui, Peoples R China
[2] Anhui Univ, Inst Phys Sci & Informat Technol, Hefei, Anhui, Peoples R China
[3] USTC, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
HILBERT TRANSFORM; FEEDBACK; GENERATION;
D O I
10.1364/AO.58.005540
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper, a vibration-displacement immunization model is proposed to measure the free spectral range of a resonant cavity by using a laser self-mixing velocimeter. The validity of this method is demonstrated by the experimental results, which can effectively get rid of low measurement accuracy related to the self-mixing vibration system due to the vibratory displacement. According to the periodic waveform separation characteristic of the self-mixing velocity signal, the free spectral range of a multilongitudinal mode diode laser is calculated to be 88.24 GHz. Moreover, the influences of different target velocities and signal sampling frequencies on the free spectral range have been analyzed in detail from the theoretical analysis. In the case of high signal sampling rate and low velocity, from which the undistorted velocity signal waveform at the integral order external cavity mode keeps stable, it is possible to obtain relatively accurate measured results. (C) 2019 Optical Society of America
引用
收藏
页码:5540 / 5546
页数:7
相关论文
共 50 条
  • [1] GaN laser self-mixing velocimeter for measuring slow flows
    Kliese, Russell
    Lim, Yah Leng
    Bosch, Thierry
    Rakic, Aleksandar D.
    OPTICS LETTERS, 2010, 35 (06) : 814 - 816
  • [2] Laser speckle velocimeter using self-mixing laser diode
    Shibata, T
    Shinohara, S
    Ikeda, H
    Yoshida, H
    Sawaki, T
    Sumi, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1996, 45 (02) : 499 - 503
  • [3] Self-mixing dual-frequency laser Doppler velocimeter
    Cheng, Chih-Hao
    Lin, Lyu-Chih
    Lin, Fan-Yi
    OPTICS EXPRESS, 2014, 22 (03): : 3600 - 3610
  • [4] Self-Mixing Dual-Frequency Laser Doppler Velocimeter
    Cheng, C. H.
    Lin, L. C.
    Lin, F. Y.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE AND INTERNATIONAL QUANTUM ELECTRONICS CONFERENCE (CLEO EUROPE/IQEC), 2013,
  • [5] Self-Mixing Laser Velocimeter for retinal blood flow measurements
    Cattini, Stefano
    Salvatori, Giorgia
    Rovati, Luigi
    OPHTHALMIC TECHNOLOGIES XVII, 2007, 6426
  • [6] Self-mixing laser speckle velocimeter for blood flow measurement
    Özdemir, SK
    Takamiya, S
    Ito, S
    Shinohara, S
    Yoshida, H
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (05) : 1029 - 1035
  • [7] New speckle velocimeter using two self-mixing laser diodes
    Ozdemir, SK
    Takasu, T
    Shinohara, S
    Yoshida, H
    Ikeda, H
    SICE '97 - PROCEEDINGS OF THE 36TH SICE ANNUAL CONFERENCE, INTERNATIONAL SESSION PAPERS, 1997, : 947 - 950
  • [8] DIRECTIONAL DISCRIMINATION IN THE SELF-MIXING TYPE LASER DOPPLER-VELOCIMETER
    SHIMIZU, ET
    APPLIED OPTICS, 1987, 26 (21): : 4541 - 4544
  • [9] Self-mixing laser Doppler velocimeter based on dual frequency lasers
    Liu, G
    Zhang, SL
    ADVANCED MATERIALS AND DEVICES FOR SENSING AND IMAGING II, 2005, 5633 : 363 - 370
  • [10] Self-mixing birefringent dual-frequency laser Doppler velocimeter
    Chen, Junbao
    Zhu, Hongbin
    Xia, Wei
    Guo, Dongmei
    Hao, Hui
    Wang, Ming
    OPTICS EXPRESS, 2017, 25 (02): : 560 - 572