Total reflection X-ray spectroscopy (TXRF) is a powerful analytical technique for qualitative and quantitative analysis of trace and ultratrace elements in a sample with lower limits of detection (LLDs) of pg/g to ng/g in concentration and absolute high fg levels are attainable. Several X-ray sources, from low power (few W), 18 kW rotating anodes to synchrotron radiation, are in use for the excitation and lead accordingly to their photon flux delivered on the sample the detection limits specified. Not only the power, but also the brilliance and focal shape are of importance for TXRF. A microfocus of 50-100 gm spot size or the line focus of diffraction tubes is best suited. Excillum developed a new approach in the design of a source: the liquid metal jet anode. In this paper the results achieved with this source are described. A versatile TXRF spectrometer with vacuum chamber designed at Atominstitut was used for the experiments. A multilayer monochromator selecting the intensive Ga-K alpha radiation was taken and the beam was collimated by 50 pm slits. Excellent results regarding geometric beam stability, high fluorescence intensities and low background were achieved leading to detection limits in the high fg range for Ni. A 100 mm(2) silicon drift detector (SDD) collimated to 80 mm2 was used to collect the fluorescence radiation. The results from measurements on single element samples are presented. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:67 / 69
页数:3
相关论文
共 50 条
  • [1] Reduction of Spectral Interference between X-ray Peaks Originating from an X-ray Tube and X-ray Fluorescence Peaks in Total Reflection X-ray Fluorescence Analysis
    Kunimura, Shinsuke
    Sugawara, Yugo
    Kudo, Shumpei
    ISIJ INTERNATIONAL, 2017, 57 (05) : 953 - 955
  • [2] QUANTITATIVE ANALYSIS OF LIQUID SAMPLES USING TOTAL REFLECTION X-RAY FLUORESCENCE
    Hashimoto, Hideki
    Iida, Yutaka
    Saisho, Hideo
    Nishioji, Hiroshi
    ANALYTICAL SCIENCES, 1991, 7 : 577 - 580
  • [3] Total reflection X-ray fluorescence
    Schmeling, Martina
    PHYSICAL SCIENCES REVIEWS, 2019, 4 (07)
  • [4] Feasibility of using Total Reflection X-ray Fluorescence Spectrometry for Drinking Water Analysis
    Silva, Isabella O.
    Trugillo, Denise Akemi F. T.
    Joanni, Edson
    Intima, Danielle Polidorio
    Nomura, Cassiana Seimi
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 5 (19): : 12 - 21
  • [5] Total reflection x-ray fluorescence analysis - a review
    Wobrauschek, P.
    X-RAY SPECTROMETRY, 2007, 36 (05) : 289 - 300
  • [6] Analysis of Beverages by Total Reflection X-ray Fluorescence
    Schmeling, Martina
    SPECTROSCOPY, 2017, 32 (07) : 28 - 29
  • [7] Polarization X-Ray Fluorescence Analysis by Milliwatt X-ray Tube
    Kawai, Jun
    Kato, Toshihide
    Imashuku, Susumu
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2024, 110 (12): : 981 - 987
  • [8] X-ray fluorescence and total external reflection X-ray fluorescence analysis of films of ferroelectric complex oxides
    Krasnolutskii, VP
    Bakirov, AA
    Poluyanova, GI
    Zakharchenko, IN
    Dudkevich, VP
    INDUSTRIAL LABORATORY, 1997, 63 (12): : 729 - 731
  • [9] Liquid-metal-jet anode X-ray tube
    Hemberg, O
    Otendal, M
    Hertz, HM
    OPTICAL ENGINEERING, 2004, 43 (07) : 1682 - 1688
  • [10] Sample preparation using plasma jet treatment for total reflection X-ray fluorescence analysis
    Tsuji, Kouichi
    Tanaka, Yudai
    Taniguchi, Naoya
    Oh, Jun-Seok
    Matsuyama, Tsugufumi
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2024, 217