Rotary Pumps and Diminished Pulsatility: Do We Need a Pulse?

被引:43
|
作者
Soucy, Kevin G. [1 ,2 ]
Koenig, Steven C. [1 ,2 ]
Giridharan, Guruprasad A. [2 ]
Sobieski, Michael A. [1 ]
Slaughter, Mark S. [1 ]
机构
[1] Univ Louisville, Div Thorac & Cardiovasc Surg, Louisville, KY 40202 USA
[2] Univ Louisville, Dept Bioengn, Cardiovasc Innovat Inst, Louisville, KY 40202 USA
关键词
ventricular assist device; heart failure; continuous flow; bridge-to-transplant; destination therapy; VENTRICULAR ASSIST DEVICE; MECHANICAL CIRCULATORY SUPPORT; END-ORGAN FUNCTION; VASCULAR SMOOTH-MUSCLE; CONTINUOUS-FLOW; HEART-FAILURE; SHEAR-STRESS; CARDIOPULMONARY BYPASS; NONPULSATILE-FLOW; DESTINATION THERAPY;
D O I
10.1097/MAT.0b013e31829f9bb3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ventricular assist devices (VADs) have been successfully used as a bridge to heart transplant and destination therapy (DT) for congestive heart failure (HF) patients. Recently, continuous flow VAD (CVAD) has emerged as an attractive clinical option for long-term mechanical support of HF patients, with bridge-to-transplant outcomes comparable with pulsatile flow VAD (PVAD). Continuous flow VADs are smaller, more reliable, and less complex than the first-generation PVAD. Despite the widespread clinical use, CVAD support has been associated with gastrointestinal bleeding, hemorrhagic strokes, and aortic valve insufficiency. Speculation that diminished arterial pressure pulsatility associated with continuous flow devices may be contributing to these complications has sparked much debate over CVAD support. Studies comparing pulsatile flow and continuous flow (CF) support have presented conflicting findings, and the relevance to CVAD as DT is uncertain due to variations in device operation, support duration, and the criteria used to quantify pulsatility. Currently, there is interest in developing control algorithms for CVAD to increase the delivered pulsatility as a strategy to mitigate adverse event risks associated with CVAD therapy. There may also be the added benefit of specific control strategies for managing CVAD therapy, potentially improving the rate of myocardial recovery and successful weaning of mechanical circulatory support.
引用
收藏
页码:355 / 366
页数:12
相关论文
共 50 条
  • [1] We Always Need a Pulse, or Do We?
    Tohid Pirbodaghi
    Journal of Cardiovascular Translational Research, 2013, 6 : 294 - 294
  • [2] We Always Need a Pulse, Or Do We??
    Leslie Miller
    Journal of Cardiovascular Translational Research, 2012, 5 : 296 - 301
  • [3] We Always Need a Pulse, or Do We?
    Pirbodaghi, Tohid
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2013, 6 (02) : 294 - 294
  • [4] We Always Need a Pulse, Or Do We??
    Miller, Leslie
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2012, 5 (03) : 296 - 301
  • [5] Feasibility of Pump Speed Modulation for Restoring Vascular Pulsatility with Rotary Blood Pumps
    Ising, Mickey S.
    Sobieski, Michael A.
    Slaughter, Mark S.
    Koenig, Steven C.
    Giridharan, Guruprasad A.
    ASAIO JOURNAL, 2015, 61 (05) : 526 - 532
  • [6] A sensorless, physiologic feedback control strategy to increase vascular pulsatility for rotary blood pumps
    Tan, Zhehuan
    Huo, Mingming
    Qin, Kairong
    El-Baz, Ayman S.
    Sethu, Palaniappan
    Wang, Yu
    Giridharan, Guruprasad A.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 83
  • [7] We need a Law! - Do we need a Law ?
    Alt-Epping, Bernd
    ZEITSCHRIFT FUR PALLIATIVMEDIZIN, 2014, 15 (06): : 241 - 242
  • [8] Transporter pharmacogenetics: do we need function? Do we need motion?
    Pastor-Anglada, Marcal
    PHARMACOGENOMICS, 2013, 14 (13) : 1537 - 1540
  • [9] WHY DO WE NEED CONTROLS - WHY DO WE NEED TO RANDOMIZE
    EDERER, F
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1975, 79 (05) : 758 - 762
  • [10] DO WE NEED NEED ASSESSMENT
    CRAVEN, N
    VETERINARY RECORD, 1990, 126 (16) : 407 - 407