Validation of Embletta portable diagnostic system for identifying patients with suspected obstructive sleep apnoea syndrome (OSAS)

被引:108
|
作者
Ng, Susanna S. S. [1 ]
Chan, Tat-On [1 ]
To, Kin-Wang [1 ]
Ngai, Jenny [1 ]
Tung, Alvin [1 ]
Ko, Fanny W. S. [1 ]
Hui, David S. C. [1 ]
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Med & Therapeut, Div Resp Med, Hong Kong, Hong Kong, Peoples R China
关键词
diagnosis; obstructive sleep apnoea; polysomnography; portable monitoring; POSITIVE AIRWAY PRESSURE; APNOEA/HYPOPNOEA SYNDROME; MEN; POPULATION; DISORDERS; DEVICE; ADULTS;
D O I
10.1111/j.1440-1843.2009.01697.x
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background and objectives: This study aimed to evaluate the diagnostic accuracy of Embletta portable diagnostic system (PDS, Medcare, Reykjavik, Iceland) for the screening of sleep apnoea in clinical practice. Methods: The Embletta PDS is a digital three-channel recording device that measures airflow through a nasal cannula connected to a pressure transducer, oxygen saturation plus both respiratory and abdominal movements via built-in effort and body position sensors. An AHI is determined based on recording time. Nocturnal polysomnography (Alice 4, Healthdyne, Atlanta, USA), with airflow measured by a nasal pressure transducer (PTAF2, Pro-Tech, Woodinville, WA, USA)) and Embletta PDS recordings, was performed simultaneously in consecutive patients with suspected OSA syndrome. The PSG recordings were analysed manually by a blinded investigator. Results: Ninety subjects were recruited and 10 failed Embletta PDS studies due to measurement failure. Among the remaining 80 subjects, 63 were males. The mean age (SD) was 51.4 (11.9) years old, BMI 27.1(4.2) kg/m(2), neck circumference 38.6 (3.6) cm and Epworth Sleepiness Score 9.7 (5.3). The AHI obtained by the Embletta PDS correlated closely with that obtained by PSG (Pearson correlation, r = 0.979, P < 0.001). Comparison of AHI based on the Embletta PDS against the PSG demonstrated high sensitivity at AHI >= 5/h (sensitivity 0.924 and specificity 0.857) and high specificity at AHI >= 20/h (sensitivity 0.853 and specificity 0.957). Conclusions: The Embletta PDS is a highly sensitive and specific screening device in quantifying AHI when compared against PSG in patients with suspected OSA syndrome.
引用
收藏
页码:336 / 342
页数:7
相关论文
共 50 条
  • [1] Validation of a portable recording device (ApneaLink) for identifying patients with suspected obstructive sleep apnoea syndrome
    Ng, S. S. S.
    Chan, T. -O.
    To, K. -W.
    Ngai, J.
    Tung, A.
    Ko, F. W. S.
    Hui, D. S. C.
    INTERNAL MEDICINE JOURNAL, 2009, 39 (11) : 757 - 762
  • [2] Validation of a Portable Recording Device (Embletta™ PDS) for Screening of Patients with Suspected Obstructive Sleep Apnea.
    Ng, S. S.
    Chan, T. O.
    Ngai, J. C.
    Tung, A. H.
    To, K. W.
    Ko, F. W.
    Hui, D. S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [3] Home sleep studies for evaluation of suspected obstructive sleep apnoea syndrome (OSAS) in children
    Patel, A
    Watson, M
    Habibi, P
    THORAX, 2004, 59 (01) : 74 - 74
  • [4] Obstructive sleep apnoea syndrome (OSAS): effects on the vestibular system
    Gallina, S.
    Dispenza, F.
    Kulamarva, G.
    Riggio, F.
    Speciale, R.
    ACTA OTORHINOLARYNGOLOGICA ITALICA, 2010, 30 (06) : 281 - 284
  • [5] Biometrics and the Severity of Obstructive Sleep Apnoea Syndrome (OSAS)
    Apetroaei, S.
    McGowan, A.
    O'Brien, A.
    Fennell, K.
    Faul, J.
    Cormican, L.
    Goodman, P.
    Burke, C.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2013, 182 : S455 - S455
  • [6] Obstructive sleep apnoea syndrome (OSAS) and cardiovascular disease
    Theolade, R
    Seibert, R
    Goerlich, E
    Michel, A
    Grandjean, P
    Ruscher, H
    Weitzenblum, E
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 1995, 44 (09): : 507 - 516
  • [7] Gender effects in obstructive sleep apnoea syndrome (OSAS)
    Silvestri, R.
    Condurso, R.
    Arico', I.
    Serra, S.
    Mento, G.
    EUROPEAN JOURNAL OF NEUROLOGY, 2009, 16 : 621 - 621
  • [8] Diagnostic accuracy of a portable recording device (MESAM IV) in suspected obstructive sleep apnoea
    Esnaola, S
    Duran, J
    InfanteRivard, C
    Rubio, R
    Fernandez, A
    EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (12) : 2597 - 2605
  • [9] False memories in patients suffering from obstructive sleep apnoea syndrome (OSAS)
    Sarhane, Majdouline
    Etcheverry, Isabelle
    Tiberge, Michel
    Daurat, Agnes
    JOURNAL OF COGNITIVE PSYCHOLOGY, 2014, 26 (06) : 662 - 669
  • [10] MASKED HYPERTENSION IN OBSTRUCTIVE SLEEP APNOEA SYNDROME (OSAS) PATIENTS: NOT SUCH A RARE CIRCUMSTANCE
    Feki, S.
    Mssead, S.
    Mahfoudh, H.
    Chaabouni, Y.
    Mnif, K.
    Jarraya, F.
    Kammoun, K.
    Kammoun, S.
    Hachicha, J.
    JOURNAL OF HYPERTENSION, 2016, 34 : E297 - E297