A modified protocol for restorative implant abutment selection by using computer-aided design and computer-aided manufacturing technology

被引:0
|
作者
Fabrega, Javier [1 ]
Rios-Santos, Jose Vicente [1 ,2 ]
Falcao, Carlos [2 ,3 ,4 ]
Herrero-Climent, Mariano [3 ,5 ]
机构
[1] Univ Complutense, Fac Odontol, Adv Esthet Program, Madrid, Spain
[2] Univ Seville, Fac Odontol, Dept Periodontol, C Avicena S-N, Seville 41009, Spain
[3] Porto Dent Inst, Oporto, Portugal
[4] Fernando Pessoa Univ, Fac Hlth Sci, Porto, Portugal
[5] Univ Seville, Fac Odontol, Seville, Spain
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2021年 / 125卷 / 02期
关键词
D O I
10.1016/j.prosdent.2019.12.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implant abutment selection is complex because of the numerous factors involved. Computer-aided design (CAD) technology allows for the virtual selection and placement of abutments after all parameters have been precisely measured. The outcome of this new protocol should be validated. Purpose. The purpose of this in vitro study was to validate a new digital protocol in which abutment selection is made through a CAD software program, the abutments are virtually placed, and the restoration is then designed based on the virtual abutments to fit the actual abutments when delivered to the implants intraorally. Material and methods. A cast with 2 parallel implants was scanned 10 times. Then, 2 abutments were placed and scanned 10 times. Twenty identical superstructures were designed and manufactured to simulate the clinical situation of a 3-unit fixed partial denture, screw-retained to 2 implants. These were divided into 2 groups -A, real abutment and B, virtual abutment -and then compared by means of digital and optical measurements. Results. No significant differences were detected for the measurements between the control and test groups in either the x-axis or y-axis; significant differences were found for the median value of the measurements obtained from both groups regarding the z-axis (P=.046). The mean gap in the virtual abutment group was 50 mm and 35 mm in the real abutment group. Conclusions. Superstructures produced after the virtual selection and placement of intermediate restorative abutments compared favorably with those produced after the digitalization of actual abutments and placement in the implant model, thus validating the proposed digital protocol for virtual abutment selection and placement.
引用
收藏
页码:341 / 348
页数:8
相关论文
共 50 条
  • [1] COMPUTER-AIDED DESIGN AND COMPUTER-AIDED MANUFACTURING
    WEINBERGSTABER, M
    [J]. DU-DIE ZEITSCHRIFT DER KULTUR, 1984, (02): : 89 - 89
  • [2] Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report
    Barros, Jose Henrique Lopo
    de Oliveira, Murilo Navarro
    Cardoso, Igor Oliveiros
    de Oliveira, Guilherme Jose Pimentel Lopes
    do Prado, Celio Jesus
    Das Neves, Flavio Domingues
    [J]. HEALTHCARE, 2023, 11 (18)
  • [3] Computer-Aided Design/Computer-Aided Manufacturing Technology in Customized Orthodontic Appliances
    Grauer, Dan
    Wiechmann, Dirk
    Heymann, Gavin C.
    Swift, Edward J., Jr.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2012, 24 (01) : 3 - 9
  • [4] Bioprinting of Multimaterials with Computer-aided Design/Computer-aided Manufacturing
    Lee, J. M.
    Sing, S. L.
    Yeong, W. Y.
    [J]. INTERNATIONAL JOURNAL OF BIOPRINTING, 2020, 6 (01) : 65 - 73
  • [5] COMPUTER-AIDED DESIGN AND COMPUTER-AIDED MANUFACTURING OF FOOT ORTHOSES
    STAATS, TB
    KRIECHBAUM, MP
    [J]. JOURNAL OF PROSTHETICS AND ORTHOTICS, 1989, 1 (03) : 182 - 186
  • [6] To Computer-Aided Design and Manufacturing or Not to Computer-Aided Design and Manufacturing? Free Fibula Flap With Computer-Aided Technique for Mandibular Reconstruction
    Zavattero, Emanuele
    Garzino-Demo, Paolo
    Fasolis, Massimo
    Ramieri, Guglielmo
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (03) : E206 - E209
  • [7] Maxillary sinus augmentation using computer-aided design/computer-aided manufacturing (CAD/CAM) technology
    Mangano, F.
    Zecca, P.
    Pozzi-Taubert, S.
    Macchi, A.
    Ricci, M.
    Luongo, G.
    Mangano, C.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2013, 9 (03): : 331 - 338
  • [8] Computer-aided design/computer-aided manufacturing skull base drill
    Couldwell, William T.
    MacDonald, Joel D.
    Thomas, Charles L.
    Hansen, Bradley C.
    Lapalikar, Aniruddha
    Thakkar, Bharat
    Balaji, Alagar K.
    [J]. NEUROSURGICAL FOCUS, 2017, 42 (05)
  • [9] Computer-Aided Design/Computer-Aided Manufacturing Implant Guide Used in Flapless Surgery for Auricular Prosthesis
    Bai, Shizhu
    Bi, Yunpeng
    Dong, Yan
    Feng, Zhihong
    Zhao, Yimin
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (06) : 1338 - 1341
  • [10] Computer-aided design and Computer-aided engineering
    Kolbasin, Alexander
    Husu, Oksana
    [J]. INTERNATIONAL SCIENCE CONFERENCE SPBWOSCE-2017 BUSINESS TECHNOLOGIES FOR SUSTAINABLE URBAN DEVELOPMENT, 2018, 170