Embolization of Fractured Bioresorbable Scaffold Struts Insights From 2-and 3-Dimensional Optical Coherence Tomography

被引:1
|
作者
Capranzano, Piera [1 ]
Francaviglia, Bruno [1 ]
Capodanno, Davide [1 ]
Di Salvo, Maria Elena [1 ]
Tamburino, Claudia Ina [1 ]
Santagati, Fabio Maria [1 ]
Tamburino, Corrado [1 ]
机构
[1] Univ Catania, Ferrarotto Hosp, Cardiovasc Dept, Citelli 1, I-95124 Catania, Italy
关键词
bioresorbable scaffolds; complications; fracture; struts embolization;
D O I
10.1016/j.jcin.2015.11.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页码:E37 / E38
页数:2
相关论文
共 50 条
  • [1] Disruption of bioresorbable vascular scaffold struts due to loss of radial integrity: insights from optical coherence tomography
    Ramalho, Ana Rita
    Marques, Joao Silva
    Pego, Guilherme Mariano
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03): : 311 - 312
  • [2] Disruption of bioresorbable vascular scaffold struts due to loss of radial integrity: insights from optical coherence tomography
    Ana Rita Ramalho
    João Silva Marques
    Guilherme Mariano Pêgo
    The International Journal of Cardiovascular Imaging, 2017, 33 : 311 - 312
  • [3] Longitudinal Elongation, Axial Compression, and Effects on Strut Geometry of Bioresorbable Vascular Scaffolds Insights From 2-and 3-Dimensional Optical Coherence Tomography Imaging
    Ohno, Yohei
    Attizzani, Guilherme F.
    Capodanno, Davide
    Tamburino, Claudia I.
    Longo, Giovanni
    Fujino, Yusuke
    Capranzano, Piera
    Tamburino, Corrado
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (03) : E35 - E37
  • [4] Automated Segmentation of Bioresorbable Vascular Scaffold Struts in Intracoronary Optical Coherence Tomography Images
    Amrute, Junedh M.
    Garcia Camarero, Tamara
    Athanasiou, Lambros
    Rikhtegar, Farhad
    Hernandez, Jose M. de la Torre
    Edelman, Elazer R.
    2017 IEEE 17TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2017, : 297 - 302
  • [6] Serial 2-Dimensional and 3-Dimensional Optical Coherence Tomography Assessment of Overhanging Struts of Drug-Eluting Absorbable Metal Scaffold
    Muramatsu, Takashi
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    Waksman, Ron
    Verheye, Stefan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (05) : 575 - 576
  • [7] Recanalized Thrombus Treated With Bioresorbable Vascular Scaffold Insights From Optical Coherence Tomography
    Gomez-Monterrosas, Omar
    Regueiro, Ander
    Santos, Alejandro
    Otsuki, Shuji
    Scalone, Giancarla
    Fernandez-Rodriguez, Diego
    Sabate, Manel
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (12) : 1453 - 1455
  • [8] Use of Bioresorbable Vascular Scaffold in Acute Dissection Insights From Optical Coherence Tomography
    Basavarajaiah, Sandeep
    Naganuma, Toru
    Qadir, Mamoon
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (01) : E5 - E9
  • [9] Automatic detection of bioresorbable vascular scaffold struts in intravascular optical coherence tomography pullback runs
    Wang, Ancong
    Nakatani, Shimpei
    Eggermont, Jeroen
    Onuma, Yoshi
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    Reiber, Johan H. C.
    Dijkstra, Jouke
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (10): : 3589 - 3602
  • [10] The Impact of Predilatation on Bioresorbable Vascular Scaffold Expansion In Vivo - insights from Optical Coherence Tomography
    Brown, Adam J.
    McCormick, Liam M.
    Braganza, Denise M.
    Hoole, Stephen P.
    West, Nick E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B172 - B172