The measuring principle and experimental results of the enthalpy probe technique for thermal plasma diagnostics are presented. Its calibration and errors are discussed. Typical results are presented for the system operation in an Ar/H-2 (5 % H-2) plasma arc jet under a reactor chamber pressure of 101.3 kPa. The plasma temperature and velocity profiles are measured. The center temperature and velocity are 6600 K and 850 m/s for plasma power 9 kW at axial location of 17 mm.
引用
收藏
页码:1909 / 1914
页数:6
相关论文
共 50 条
  • [1] Enthalpy Probe Technique for Thermal Plasma Diagnostics
    冯晓珍
    Plasma Science & Technology, 2003, (04) : 1909 - 1914
  • [2] ANALYSIS OF THE ENTHALPY PROBE TECHNIQUE FOR THERMAL PLASMA DIAGNOSTICS
    RAHMANE, M
    SOUCY, G
    BOULOS, MI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (06): : 3424 - 3431
  • [3] Analysis of thermal plasma diagnostics based on enthalpy probe system
    Wang, Jianwei
    Wang, Pingyang
    Peng, Li
    VACUUM, 2022, 206
  • [4] DIAGNOSTICS OF A THERMAL PLASMA-JET BY OPTICAL-EMISSION SPECTROSCOPY AND ENTHALPY PROBE MEASUREMENTS
    CHEN, WLT
    HEBERLEIN, J
    PFENDER, E
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 51 - IEC
  • [5] Design of a thermal probe for the plasma diagnostics
    Matsuura, H
    Michimoto, K
    CONTRIBUTIONS TO PLASMA PHYSICS, 2004, 44 (7-8) : 677 - 682
  • [6] Enthalpy probe diagnostics of an atmospheric pressure argon microwave induced plasma
    Destefani, CA
    Murphy, AB
    Siores, E
    Elchinger, MF
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2000, 33 (16) : 1996 - 2003
  • [7] ENTHALPY PROBE PERFORMANCE IN COMPRESSIBLE THERMAL PLASMA JETS
    FINCKE, JR
    SWANK, WD
    SNYDER, SC
    HAGGARD, DC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (12): : 3585 - 3593
  • [8] Improvement of thermal probe method for the plasma diagnostics
    Matsuura, H
    Michimoto, K
    THIN SOLID FILMS, 2006, 506 : 688 - 691
  • [9] MODULAR ENTHALPY PROBE AND GAS ANALYZER FOR THERMAL PLASMA MEASUREMENTS
    SWANK, WD
    FINCKE, JR
    HAGGARD, DC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (01): : 56 - 62
  • [10] A retarding field thermal probe for combined plasma diagnostics
    Felix Schlichting
    Holger Kersten
    EPJ Techniques and Instrumentation, 10