Highly sensitive chemiluminescence detection for PDMS/glass micro-chip electrophoresis

被引:0
|
作者
Huang, XY [1 ]
Wang, JN [1 ]
Chen, L [1 ]
Ren, JC [1 ]
机构
[1] Shanghai Jiao Tong Univ, Coll Chem & Chem Engn, Shanghai 200240, Peoples R China
关键词
micro-chip; electrophoresis; chemiluminenscence; poly(dimethylsiloxane);
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper described a highly sensitive chemiluminescence detection system for micro-chip electrophoresis (MCE) based on luminol-hydrogen peroxide reaction catalyzed by the metal ions. The micro-chip was composed of poly(dimethylsiloxane) (PDMS) and glass, and was fabricated by micro-machining technology. The surface of channels was dynamically modified by polydimethylacrylamide (PDMA) in order to eliminate unhomogeneous electroosmotic flow (EOF) of the PDMS/glass chip, adsorption of molecules, and improve hydrophobicity on PDMS surface. The detection modes, reagent mix procedures and reaction conditions were optimized and the detection limit of 5 x 10(-11) mol/L for cobalt (II) was achieved by NICE with chemiluminescence detection, which was about four orders of magnitude more sensitive than that reported in the reference.
引用
收藏
页码:683 / 686
页数:4
相关论文
共 50 条
  • [1] Highly Sensitive Chemiluminescence Detection for PDMS/GIass Micro-chip Electrophoresis
    Xiang Yi HUANG
    ChineseChemicalLetters, 2004, (06) : 683 - 686
  • [2] Ionode detection and capillary electrophoresis integrated on a polymer micro-chip
    Bianchi, F
    Lee, HJ
    Girault, HH
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 523 (1-2): : 40 - 48
  • [3] An integrated micro-chip for rapid detection of magnetic particles
    Gooneratne, Chinthaka P.
    Liang, Cai
    Giouroudi, Ioanna
    Kosel, Juergen
    JOURNAL OF APPLIED PHYSICS, 2012, 111 (07)
  • [4] Rapid fabrication of monolithic PDMS microchips and highly sensitive chemiluminescence detection for amino acids
    Yan, LS
    Liang, N
    Luo, GA
    Wang, YM
    Wang, JY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (07): : 1193 - 1197
  • [5] HIGHLY SENSITIVE DETECTION OF PROTEINS SEPARATED BY CAPILLARY ZONE ELECTROPHORESIS USING ONLINE CHEMILUMINESCENCE DETECTION
    HARA, T
    NISHIDA, H
    NAKAJIMA, R
    ANALYTICAL SCIENCES, 1994, 10 (05) : 823 - 825
  • [6] An effective PDMS microfluidic chip for chemiluminescence detection of cobalt (II) in water
    Xueye Chen
    Chong Liu
    Zheng Xu
    Yuzhen Pan
    Junshan Liu
    Liqun Du
    Microsystem Technologies, 2013, 19 : 99 - 103
  • [7] An effective PDMS microfluidic chip for chemiluminescence detection of cobalt (II) in water
    Chen, Xueye
    Liu, Chong
    Xu, Zheng
    Pan, Yuzhen
    Liu, Junshan
    Du, Liqun
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2013, 19 (01): : 99 - 103
  • [8] Integration of a flow-type chemiluminescence detector on a glass electrophoresis chip
    Su, RG
    Lin, JM
    Uchiyama, K
    Yamada, M
    TALANTA, 2004, 64 (04) : 1024 - 1029
  • [9] Highly sensitive immunoassay of carcinoembryonic antigen by capillary electrophoresis with gold nanoparticles amplified chemiluminescence detection
    Jiang, Jing
    Zhao, Shulin
    Huang, Yong
    Qin, Guoxin
    Ye, Fanggui
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1282 : 161 - 166
  • [10] GLASS CHAOTIC CHIP MIXER AND USE IN CHIP FLOW CHEMILUMINESCENCE DETECTION
    Fang Fang
    Wu Zhiyong
    Xu Zhangrun
    Dai Jing
    IFPT'6: PROGRESS ON POST-GENOME TECHNOLOGIES, PROCEEDINGS, 2009, : 132 - +