Validation of the updated ArthroS simulator: face and construct validity of a passive haptic virtual reality simulator with novel performance metrics

被引:39
|
作者
Roberts, Patrick Garfjeld [1 ]
Guyver, Paul [2 ]
Baldwin, Mathew [3 ]
Akhtar, Kash [4 ]
Alvand, Abtin [1 ]
Price, Andrew J. [1 ]
Rees, Jonathan L. [1 ]
机构
[1] Univ Oxford, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford, England
[2] Plymouth Hosp NHS Trust, MDHU Derriford, Oxford, England
[3] Hlth Educ Thames Valley, Oxford, England
[4] Queen Mary Univ London, Blizard Inst, Barts & London Sch Med & Dent, London, England
关键词
Simulation; Arthroscopy; Training; Virtual reality; KNEE ARTHROSCOPY; SURGICAL SKILL; COMPETENCE; SURGEONS; MODEL;
D O I
10.1007/s00167-016-4114-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To assess the construct and face validity of ArthroS, a passive haptic VR simulator. A secondary aim was to evaluate the novel performance metrics produced by this simulator. Two groups of 30 participants, each divided into novice, intermediate or expert based on arthroscopic experience, completed three separate tasks on either the knee or shoulder module of the simulator. Performance was recorded using 12 automatically generated performance metrics and video footage of the arthroscopic procedures. The videos were blindly assessed using a validated global rating scale (GRS). Participants completed a survey about the simulator's realism and training utility. This new simulator demonstrated construct validity of its tasks when evaluated against a GRS (p 0.003 in all cases). Regarding it's automatically generated performance metrics, established outputs such as time taken (p 0.001) and instrument path length (p 0.007) also demonstrated good construct validity. However, two-thirds of the proposed 'novel metrics' the simulator reports could not distinguish participants based on arthroscopic experience. Face validity assessment rated the simulator as a realistic and useful tool for trainees, but the passive haptic feedback (a key feature of this simulator) is rated as less realistic. The ArthroS simulator has good task construct validity based on established objective outputs, but some of the novel performance metrics could not distinguish between surgical experience. The passive haptic feedback of the simulator also needs improvement. If simulators could offer automated and validated performance feedback, this would facilitate improvements in the delivery of training by allowing trainees to practise and self-assess.
引用
收藏
页码:616 / 625
页数:10
相关论文
共 50 条
  • [1] Validation of the updated ArthroS simulator: face and construct validity of a passive haptic virtual reality simulator with novel performance metrics
    Patrick Garfjeld Roberts
    Paul Guyver
    Mathew Baldwin
    Kash Akhtar
    Abtin Alvand
    Andrew J. Price
    Jonathan L. Rees
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 616 - 625
  • [2] Face and construct validation of a novel virtual reality robotic simulator
    Sethi, Amanjot S.
    Peine, William J.
    Mohammadi, Yousef
    Gardner, Thomas A.
    Koch, Michael O.
    Sundaram, Chandru P.
    [J]. JOURNAL OF UROLOGY, 2008, 179 (04): : 660 - 660
  • [3] Validation of the ArthroS virtual reality simulator for arthroscopic skills
    J. J. Stunt
    G. M. M. J. Kerkhoffs
    C. N. van Dijk
    G. J. M. Tuijthof
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 3436 - 3442
  • [4] Validation of the ArthroS virtual reality simulator for arthroscopic skills
    Stunt, J. J.
    Kerkhoffs, G. M. M. J.
    van Dijk, C. N.
    Tuijthof, G. J. M.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (11) : 3436 - 3442
  • [5] Construct and face validity of SINERGIA laparoscopic virtual reality simulator
    Luisa F. Sánchez-Peralta
    Francisco M. Sánchez-Margallo
    José Luis Moyano-Cuevas
    José Blas Pagador
    Silvia Enciso-Sanz
    Patricia Sánchez-González
    Enrique J. Gómez-Aguilera
    Jesús Usón-Gargallo
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2010, 5 : 307 - 315
  • [6] Construct and face validity of SINERGIA laparoscopic virtual reality simulator
    Sanchez-Peralta, Luisa F.
    Sanchez-Margallo, Francisco M.
    Moyano-Cuevas, Jose Luis
    Blas Pagador, Jose
    Enciso-Sanz, Silvia
    Sanchez-Gonzalez, Patricia
    Gomez-Aguilera, Enrique J.
    Uson-Gargallo, Jesus
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (04) : 307 - 315
  • [7] Construct Validity and Expert Benchmarking of the Haptic Virtual Reality Dental Simulator
    Suebnukarn, Siriwan
    Chaisombat, Monthalee
    Kongpunwijit, Thanapohn
    Rhienmora, Phattanapon
    [J]. JOURNAL OF DENTAL EDUCATION, 2014, 78 (10) : 1442 - 1450
  • [8] Face validity, construct validity and training benefits of a virtual reality turp simulator
    Bright, Elizabeth
    Vine, Samuel
    Wilson, Mark R.
    Masters, Rich S. W.
    McGrath, John S.
    [J]. INTERNATIONAL JOURNAL OF SURGERY, 2012, 10 (03) : 163 - 166
  • [9] Face, content and construct validity of a virtual reality simulator for robotic surgery
    Gavazzi, A.
    Bahsoun, A.
    Van Haute, W.
    Khan, M. S.
    Dasgupta, P.
    [J]. BRITISH JOURNAL OF SURGERY, 2011, 98 : 51 - 51
  • [10] Limitations of haptic feedback devices on construct validity of the LapSim® virtual reality simulator
    Cecilie Våpenstad
    Erlend Fagertun Hofstad
    Lars Eirik Bø
    Magdalena Karolina Chmarra
    Esther Kuhry
    Gjermund Johnsen
    Ronald Mårvik
    Thomas Langø
    [J]. Surgical Endoscopy, 2013, 27 : 1386 - 1396