Does the real-time ultrasound guidance provide safer venipuncture in implantable venous port implantation?

被引:8
|
作者
Yildirim, Ilknur [1 ]
Tutuncu, Ayse Cigdem [2 ]
Bademler, Suleyman [3 ]
Ozgur, Ilker [4 ]
Demiray, Mukaddes [5 ]
Karanlik, Hasan [3 ]
机构
[1] Istanbul Univ, Inst Oncol, Dept Anesthesiol, Istanbul, Turkey
[2] Istanbul Univ, Cerrahpasa Fac Med, Dept Anesthesiol, TR-34098 Istanbul, Turkey
[3] Istanbul Univ, Inst Oncol, Dept Surg, Istanbul, Turkey
[4] Acibadem Int Hosp, Dept Surg, Istanbul, Turkey
[5] Okmeydani Educ & Res Hosp, Dept Surg, Istanbul, Turkey
来源
JOURNAL OF VASCULAR ACCESS | 2018年 / 19卷 / 03期
关键词
Implantable venous port; ultrasound-guided; venipuncture; SUBCLAVIAN-VEIN CATHETERIZATION; INTERVENTIONAL RADIOLOGISTS; ACCESS DEVICE; RANDOMIZED-TRIAL; CANCER-PATIENTS; COMPLICATIONS; PLACEMENT; EXPERIENCE; INSERTION; CHILDREN;
D O I
10.1177/1129729817752606
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Aim: To examine whether the real-time ultrasound-guided venipuncture for implantable venous port placement is safer than the traditional venipuncture. Methods: The study analyzed the results of 2153 venous ports placed consecutively from January 2009 to January 2016. A total of 922 patients in group I and 1231 patients in group 2 were admitted with venous port placed using the traditional landmark subclavian approach and real-time ultrasound-guided axillary approach, respectively. Sociodemographic characteristics of patients, early (pneumothorax, pinch-off syndrome, arterial puncture, hematoma, and malposition arrhythmia) and late (deep vein thrombosis, obstruction, infection, erosion-dehiscence, and rotation of the port chamber) complications and the association of these complications with the implantation method were evaluated. Results: There were no significant differences in the sociodemographic characteristics of the patients between the two groups. The overall and early complications in group 2 were significantly lower than those in group I. Pinch-off syndrome only developed in group I. Seven patients and two patients had pneumothorax in groups I and 2, respectively. Puncture number was significantly associated with the development of the overall complications. Conclusion: The ultrasound-guided axillary approach may be preferred as a method to reduce the risk of both early and late complications. Large, randomized, controlled prospective trials will be helpful in determining a safer implantable venous port implantation technique.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
  • [1] ULTRASONIC REAL-TIME GUIDANCE FOR SUBCLAVIAN VENIPUNCTURE
    SUKIGARA, M
    YAMAZAKI, T
    HATANAKA, M
    NAGASHIMA, N
    OMOTO, R
    SURGERY GYNECOLOGY & OBSTETRICS, 1988, 167 (03): : 239 - 242
  • [2] REAL-TIME ULTRASOUND GUIDANCE TO INCREASE SUCCESS OF UMBILICAL VENOUS CANNULATION
    Kozyak, Benjamin
    Fraga, Maria
    Juliano, Courteny
    Bhombal, Shazia
    Munson, David
    Brandsma, Erik
    Stoller, Jason
    Jain, Ankit
    Kesman, Russell
    Meshkati, Malorie
    Noh, Caroline
    DeWitt, Aaron
    Costarino, Andrew
    Hehir, David
    Groves, Alan
    CRITICAL CARE MEDICINE, 2022, 50 (01) : 522 - 522
  • [3] Real-time Ultrasound Guidance to Increase Success of Umbilical Venous Cannulation
    Kozyak, Benjamin W.
    Groves, Alan M.
    Fraga, Maria V.
    Juliano, Courtney E.
    Bhombal, Shazia
    Munson, David A.
    Brandsma, Erik
    Stoller, Jason Z.
    Jain, Ankit
    Costarino, Andrew T.
    Hehir, David A.
    PEDIATRICS, 2022, 149 (01)
  • [4] REAL-TIME ULTRASOUND IMAGING AIDS JUGULAR VENIPUNCTURE
    BOND, DM
    CHAMPION, LK
    NOLAN, R
    ANESTHESIA AND ANALGESIA, 1989, 68 (05): : 700 - 701
  • [5] PACEMAKER IMPLANTATION USING REAL-TIME ULTRASOUND GUIDANCE FOR SUBCLAVIAN VEIN ACCESS
    Darlington, E. L.
    Rittoo, D.
    Patel, B.
    Choi, K.
    HEART, 2012, 98 : A35 - A35
  • [6] Real-time needle guidance for venipuncture based on optical coherence tomography
    Farouki, Rida T.
    Swett, Jack R.
    Rohlen, Rachel Ward
    Smith, David B.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2021, 9 (06): : 643 - 650
  • [7] Novel Ultrasound Guidance System for Real-time Central Venous Cannulation: Safety and Efficacy
    Ferre, Robinson M.
    Mercier, Mark
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2014, 15 (04) : 536 - 540
  • [8] Real-Time Ultrasound Guidance for Umbilical Venous Cannulation in Neonates With Congenital Heart Disease
    Kozyak, Benjamin W.
    Fraga, Maria, V
    Juliano, Courtney E.
    Bhombal, Shazia
    Munson, David A.
    Brandsma, Erik
    Stoller, Jason Z.
    Jain, Ankit
    Kesman, Russell
    Meshkati, Malorie
    Noh, Caroline Y.
    Dewitt, Aaron G.
    Costarino, Andrew T.
    Hehir, David A.
    Groves, Alan M.
    PEDIATRIC CRITICAL CARE MEDICINE, 2022, 23 (05) : E257 - E266
  • [9] REAL-TIME ULTRASOUND FOR VENOUS CATHETER PLACEMENT
    BRANCACCIO, D
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1995, 18 (03): : 115 - 116
  • [10] REAL-TIME ULTRASOUND SCANNING IN THE PLANNING AND GUIDANCE OF PERICARDIOCENTESIS
    CLARKE, DP
    COSGROVE, DO
    CLINICAL RADIOLOGY, 1987, 38 (02) : 119 - 122