The experimental characterization of a lithium bromide-water absorption chiller and the development of a calibrated model

被引:11
|
作者
Beausoleil-Morrison, Ian [1 ]
Johnson, Geoffrey [1 ]
Kemery, Briana Paige [1 ]
机构
[1] Carleton Univ, Fac Engn & Design, Sustainable Bldg Energy Syst, Ottawa, ON K1S 5B6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Absorption chiller; Solar cooling; Calibrated model; COOLING SYSTEM; SIMULATION; PERFORMANCE; DESIGN; REFRIGERATOR;
D O I
10.1016/j.solener.2015.09.009
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Small-scale solar air conditioning systems based upon thermally activated chillers offer great potential for cooling houses with minimal demands upon the central electrical system. Building performance simulation can be used to assess the potential of the technology and to explore the impact of system design (e.g. type and area of solar collectors, volume of hot and cold thermal stores, operating strategies), but only if appropriate models calibrated with accurate and reliable data are available. Experiments were conducted on a commercially available lithium bromide water absorption chiller under a controlled set of operating conditions. Instrumentation was selected, calibrated, and installed in order to derive quantities of interest at acceptable levels of measurement uncertainty. Over this range of experiments, the cooling capacity varied from 6.9 kW to 40.5 kW, and the thermal coefficient of performance ranged from 0.56 to 0.83. A quasi-steady-state model suitable for use in building performance simulations that expressed the chiller's performance was developed. Based upon statistical signfficance testing, it was found that the rates of heat transfer to both the generator and the evaporator could be expressed as linear functions of the generator inlet temperature, absorber/condenser inlet temperature, and flow rate of water to the generator. The validity of the calibrated model was then tested using measurements from a disjunct experiment whose data were not used to calibrate the model. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:368 / 381
页数:14
相关论文
共 50 条
  • [1] Absorption cooling: A review of lithium bromide-water chiller technologies
    Wang, Xiaolin
    Chua, Hui T.
    [J]. Recent Patents on Mechanical Engineering, 2009, 2 (03) : 193 - 213
  • [2] Performance characteristics of a solar driven lithium bromide-water absorption chiller integrated with absorption energy storage
    Ibrahim, Nasiru I.
    Al-Sulaiman, Fahad A.
    Ani, Farid Nasir
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 150 : 188 - 200
  • [3] Modeling the performance of small capacity lithium bromide-water absorption chiller operated by solar energy
    Saman, NF
    Said, WADK
    [J]. IECEC 96 - PROCEEDINGS OF THE 31ST INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4, 1996, : 1691 - 1696
  • [4] Parametric Study of a Single Effect Lithium Bromide-Water Absorption Chiller Powered by a Renewable Heat Source
    Tawalbeh, Muhammad
    Salameh, Tareq
    Albawab, Mona
    Al-Othman, Amani
    Assad, Mamdouh El Haj
    Alami, Abdul H.
    [J]. JOURNAL OF SUSTAINABLE DEVELOPMENT OF ENERGY WATER AND ENVIRONMENT SYSTEMS-JSDEWES, 2020, 8 (03): : 464 - 475
  • [5] Comparison and analysis of lithium bromide-water absorption chillers using plastic heat transfer tubes and traditional lithium bromide-water absorption chillers
    Zhang, Xue-dong
    [J]. World Academy of Science, Engineering and Technology, 2010, 41 : 573 - 576
  • [6] Performance analysis and optimization of new double effect lithium bromide-water absorption chiller with series and parallel flows
    Chahartaghi, Mahmood
    Golmohammadi, Hesam
    Shojaei, Arsalan Faghih
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 73 - 87
  • [7] Experimental investigation on the performance of a solar powered lithium bromide-water absorption cooling system
    Li, Ming
    Xu, Chengmu
    Hassanien, Reda Hassanien Emam
    Xu, Yongfeng
    Zhuang, Binwei
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 71 : 46 - 59
  • [8] The experimental investigation on the plastic heat exchanger applied in Lithium Bromide-Water absorption chillers
    Zhang, X. B.
    Hu, Y. C.
    Yu, Z. T.
    Li, W.
    [J]. CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 366 - 370
  • [9] Transient Modeling of a Lithium Bromide - Water Absorption Chiller
    Li, Ang
    Loh, Wai Soong
    Ng, Kim Choon
    [J]. ADVANCES IN THERMOFLUIDS, 2013, 388 : 83 - 90
  • [10] Performance assessment of an integrated free cooling and solar powered single-effect lithium bromide-water absorption chiller
    Ali, Ahmed Hamza H.
    Noeres, Peter
    Pollerberg, Clemens
    [J]. SOLAR ENERGY, 2008, 82 (11) : 1021 - 1030