Effect of Acid Neutralization and Mechanical Cycling on the Microtensile Bond Strength of Glass-ceramic Inlays

被引:29
|
作者
Saavedra, G.
Ariki, E. K.
Federico, C. D.
Galhano, G.
Zamboni, S.
Baldissara, P. [1 ]
Bottino, M. A. [2 ]
Valandro, L. F. [3 ]
机构
[1] Univ Bologna, Div Prosthodont, Dept Oral Sci Alma Mater Studiorum, Bologna, Italy
[2] Sao Paulo State Univ UNESP, Sao Jose Campos Dent Sch, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, Brazil
[3] Univ Fed Santa Maria, Div Prosthodont, Dept Restorat Dent, BR-97119900 Santa Maria, RS, Brazil
关键词
FRACTURE-RESISTANCE; CLINICAL-EVALUATION; PORCELAIN; SURFACE; FATIGUE; RESTORATIONS; PERFORMANCE; ADHESIVES; SILANE; CROWNS;
D O I
10.2341/08-68
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the hypothesis that a process of hydrofluoric acid precipitate neutralization and fatigue load cycling performed on human premolars restored with ceramic inlays had an influence on microtensile bond strength results (MTBS). Methods: MOD inlay preparations were performed in 40 premolars (with their roots embedded in acrylic resin). Forty ceramic restorations were prepared using glass-ceramic (IPS Empress). The inner surfaces of all the restorations were etched with 10% hydrofluoric acid for 60 seconds, rinsed with water and dried. The specimens were divided into two groups (N=20): 1-without neutralization; 2-with neutralization. All the restorations were silanized and adhesively cemented (self-curing and self-etching luting composite system, Multilink). Ten premolars from each group were submitted to mechanical cycling (1,400,000 cycles, 50N, 37 degrees C). After cycling, the samples were sectioned to produce non-trimmed beam specimens (vestibular dentin-restoration-lingual dentin set), which were submitted to microtensile testing. Results: Bond strength was significantly affected by the surface treatment (p<0.0001) (no neutralization > neutralization) and mechanical cycling (p<0.0001) (control > cycling) (2-way ANOVA and Tukey test, alpha=.05). Conclusion: Hydrofluoric acid precipitate neutralization appears to significantly damage the resin bond to glass-ceramic and should not be recommended. The clinical simulation of the specimens, by using mechanical cycling, is important when evaluating the ceramic-dentin bond.
引用
收藏
页码:211 / 216
页数:6
相关论文
共 50 条
  • [1] Ceramic Inlays: Effect of Mechanical Cycling and Ceramic Type on Restoration-dentin Bond Strength
    Trindade, F. Z.
    Kleverlaan, C. J.
    da Silva, L. H.
    Feilzer, A. J.
    Cesar, P. F.
    Bottino, M. A.
    Valandro, L. F.
    OPERATIVE DENTISTRY, 2016, 41 (04) : E102 - E117
  • [2] THE LONGEVITY OF GLASS-CERAMIC INLAYS
    ROULET, JF
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 405 - 405
  • [3] The effect of heat treatment and surface neutralization on bond strength of orthodontic brackets to lithium disilicate glass-ceramic
    Alaqeel, Samer M.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 103
  • [4] Microtensile bond strength of a resin cement to a novel fluorcanasite glass-ceramic following different surface treatments
    Pollington, Sarah
    Fabianelli, Andrea
    van Noort, Richard
    DENTAL MATERIALS, 2010, 26 (09) : 864 - 872
  • [5] Bond Strength of Basalt Based Glass-Ceramic Coatings
    Bayrak, G.
    Ercenk, E.
    Sen, U.
    Yilmaz, S.
    ACTA PHYSICA POLONICA A, 2014, 125 (02) : 620 - 622
  • [6] Influence of ceramic surface conditioning and resin cements on microtensile bond strength to a glass ceramic
    Pisani-Proenca, Jatyr
    Erhardt, Maria Carolina G.
    Valandro, Luiz Felipe
    Gutierrez-Aceves, Guillermo
    Bolanos-Carmona, Maria Victoria
    Del Castillo-Salmeron, Ramon
    Bottino, Marco Antonio
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (06): : 412 - 417
  • [7] STRENGTH OF A GLASS-CERAMIC
    KAY, JF
    DOREMUS, RH
    AMERICAN CERAMIC SOCIETY BULLETIN, 1974, 53 (04): : 350 - 350
  • [8] Effect of universal adhesives on microtensile bond strength to hybrid ceramic
    Awad, Mohamed M.
    Albedaiwi, Lamees
    Almahdy, Ahmed
    Khan, Rawaiz
    Silikas, Nick
    Hatamleh, Muhanad M.
    Alkhtani, Fahad M.
    Alrahlah, Ali
    BMC ORAL HEALTH, 2019, 19 (01)
  • [9] Effect of universal adhesives on microtensile bond strength to hybrid ceramic
    Mohamed M. Awad
    Lamees Albedaiwi
    Ahmed Almahdy
    Rawaiz Khan
    Nick Silikas
    Muhanad M. Hatamleh
    Fahad M. Alkhtani
    Ali Alrahlah
    BMC Oral Health, 19
  • [10] Effect of pH cycling frequency on glass-ceramic corrosion
    Hsu S.-M.
    Ren F.
    Batich C.D.
    Clark A.E.
    Neal D.
    Esquivel-Upshaw J.F.
    Esquivel-Upshaw, Josephine F. (jesquivel@dental.ufl.edu), 1600, MDPI AG, Postfach, Basel, CH-4005, Switzerland (13):