Development and application of a UPLC-MS/MS method for P-glycoprotein quantification in human tumor cells

被引:8
|
作者
Qiu, Zhaohui [1 ]
Peng, Jie [1 ]
Mou, Lingli [2 ]
Li, Xiao [3 ]
Meng, Fanqi [1 ]
Yu, Peng [1 ]
机构
[1] Cent S Univ, Sch Xiangya Pharmaceut Sci, 172 Tong Zi Po Rd, Changsha 410013, Hunan, Peoples R China
[2] Hunan Normal Univ, Med Coll, 371 Tong Zi Po Rd, Changsha 410006, Hunan, Peoples R China
[3] Changsha Duxact Biotech Co Ltd, C10 Bldg,Lugu S&T Pk,28 Lutian Rd, Changsha 411000, Hunan, Peoples R China
关键词
UPLC-MS/MS; P-gp quantification; Human tumor cells; Linear regression; TANDEM MASS-SPECTROMETRY; MEDIATED MULTIDRUG-RESISTANCE; TARGETED PROTEOMICS; DRUG TRANSPORTERS; EXPRESSION; QUANTITATION; PROTEINS; PROLIFERATION;
D O I
10.1016/j.jchromb.2018.03.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multidrug resistance (MDR) of tumors occurs when tumor cells exhibit reduced sensitivity to a large number of unrelated drugs. The molecular mechanism of MDR commonly involves overexpression of the plasma membrane drug efflux pump P-glycoprotein (P-gp). Overexpression of P-gp may be induced by the selection and/or adaptation of cells during exposure to chemotherapeutic drugs, referred to as acquired P-gp-mediated MDR. This study aimed to establish a P-gp quantification method by Ultra Performance Liquid Chromatography and Tandem Mass Spectrometry (UPLC-MS/MS) to better understand the regulation of P-gp expression and its relationship with the level of drug resistance. Absolute P-gp expression was determined in the human tumor cells MCF-7, HepG-2, and SMMC-7721 and their corresponding drug-resistant subclones MCF-7/ADMs, MCF-7MXs, MCF-7/MTXs, HepG-2/ADMs, HepG-2/MXs, HepG-2/MIXs, SMMC-7721/ADMs, SMMC-7721/MXs and SMMC-7721/MTXs. A unique 10-mer Cryptic peptide (IATEAIENFR) of P-gp was synthesized for developing the quantitative UPLC-MS/MS method with the stable isotope labeled signature peptide IATEAI (C-13(6), N-15(1)) ENFR as the internal standard (IS). The detection signal was linear in the range of 0.1-100 ng mL(-1). Quality control (QC) data showed that the within-run and between-run precision (%RSD) and accuracy (%RE) conformed to acceptable criteria of +/- 15% for the calibration standards and QCs (+/- 20% at the LLOQ). The UPLC-MS/MS method was first applied to quantify P-gp in HepG-2 and SMMC-7721 cells and their drug-resistant subclones. The results confirmed that P-gp expression in most drug-resistant subclones increase significantly compared to parental tumor cells but varied among different types of drugs or tumor cells. This outcome was then compared with published reports and discrepancy was observed in HepG2 cell lines mainly due to different sample types and samples sources. Additionally, P-gp mRNA results ascertained that overexpression of P-gp in subclones was not only regulated by MDR1. The linear correlation between RI and logarithm-transformed P-gp expression was moderate or high and statistically significantly different in subclones, except for SMMC-7721/ADMs. The present study is the first to demonstrate the quantitative relationship between RI and P-gp expression by linear regression modeling and expanded the number of efflux transporters related to MDR quantifiable by LC-MS/MS to better understand the biological significance of effluent transporter expression.
引用
收藏
页码:14 / 22
页数:9
相关论文
共 50 条
  • [1] Development of a method by UPLC-MS/MS for the quantification of tizoxanide in human plasma and its pharmacokinetic application
    Marcelin-Jimenez, Gabriel
    Contreras-Zavala, Leticia
    Maggi-Castellanos, Martha
    Angeles-Moreno, Alionka P.
    Garcia-Gonzalez, Alberto
    BIOANALYSIS, 2012, 4 (08) : 909 - 917
  • [2] Development of a robust UPLC-MS/MS method for the quantification of riluzole in human plasma and its application in pharmacokinetics
    Sun, Zhuo
    Liu, Xin
    Zuo, Wei
    Fu, Qiang
    Xu, Tingting
    Cui, Liying
    Zhang, Bo
    Peng, Ying
    FRONTIERS IN PHARMACOLOGY, 2023, 14
  • [3] Development and validation of a UPLC-MS/MS method for quantification of doxofylline and its metabolites in human plasma
    Fang, Li-Na
    Mao, Ming-Qing
    Zhao, Xiao-Hua
    Yang, Ling
    Jia, Hui
    Xia, Shu-Yue
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 174 : 220 - 225
  • [4] Development, validation, and application of a simple UPLC-MS/MS method for simultaneous quantification of five traditional antipsychotics in human plasma
    Fan, Liju
    An, Jing
    Cui, Yanjun
    Dong, Zhanjun
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (09)
  • [5] Highly sensitive UPLC-MS/MS method for the quantification of paromomycin in human plasma
    Roseboom, Ignace C.
    Thijssen, Bas
    Rosing, Hilde
    Mbui, Jane
    Beijnen, Jos H.
    Dorlo, Thomas P. C.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 185
  • [6] Development and validation of a UPLC-MS/MS assay for the quantification of simotinib in human plasma
    Li, Ning
    Han, Xiaohong
    Du, Ping
    Song, Yuanyuan
    Hu, Xingsheng
    Yang, Sheng
    Shi, Yuankai
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (06) : 1799 - 1805
  • [7] Development of a rapid UPLC-MS/MS method for quantification of saxagliptin in rat plasma and application to pharmacokinetic study
    Gao, Jing-wen
    Yuan, Yue-mei
    Lu, Ya-song
    Yao, Mei-cun
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (12) : 1482 - 1487
  • [8] Simple and rapid UPLC-MS/MS method for quantification of entecavir in human plasma: Application to a bioequivalence study
    Hou, Zhen-yan
    Yan, Miao
    Cai, Hua-lin
    Deng, Yang
    Wu, Hui-hui
    Tang, Zhi
    Hu, Xiao-yang
    Yang, Xi-ding
    Zhang, Bi-kui
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2018, 56 (04) : 197 - 204
  • [9] Quantification of amlodipine and atorvastatin in human plasma by UPLC-MS/MS method and its application to a bioequivalence study
    Rezk, Mamdouh R.
    Badr, Kamal A.
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (07)
  • [10] Novel and sensitive UPLC-MS/MS method for quantification of sofosbuvir in human plasma: application to a bioequivalence study
    Rezk, Mamdouh R.
    Basalious, Emad B.
    Amin, Mohammed E.
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (09) : 1354 - 1362