Measurement of land surface BRDF with spatial instability for vicarious calibration

被引:3
|
作者
Tsuchida, S [1 ]
Sato, I [1 ]
Okada, S [1 ]
机构
[1] Geol Survey Japan, Tsukuba, Ibaraki 3058567, Japan
关键词
BRDF; vicarious calibration; spectroradiometer; CCD digital camera; Tottori Sand Dune;
D O I
10.1117/12.373193
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The land surface for vicarious calibration, e.g. playa, desert sand and snowfield, seemed to be similar to lambertian surface, and the bidirectional reflectance factors were then assumed to be lambertian in many cases of vicarious calibration even if it actually showed the departure from lambertian behavior. Recently, the measurement of bidirectional reflectance distribution function (BRDF) of ground surface becomes important according to the improvement of the vicarious calibration method that leads to more precision coefficients. The scale of in-situ measured BRDF is very different from satellite based BRDF, which generally causes the problem of spatial instability in the in-situ measurement. To estimate the satellite based BRDF, it is better to measure the BRDF at the many points in the ground site. However, most of the previous instruments can measure only a few points at the overpass time of satellite, because the instruments are heavy and need a long time to measure the BRDF. In this study, new BRDF measurement system that has a potential to correct spatial instability using the spectroradiometer and CCD digital camera is proposed, and its capacity and limit are discussed using atmospheric and land surface radiative transfer models.
引用
收藏
页码:254 / 258
页数:5
相关论文
共 50 条
  • [1] Instrument for retrieval of BRDF data for vicarious calibration
    Nandy, P
    Thome, K
    Biggar, S
    IGARSS '98 - 1998 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, PROCEEDINGS VOLS 1-5: SENSING AND MANAGING THE ENVIRONMENT, 1998, : 562 - 564
  • [2] BRDF and surface-surround effects on SPOT-HRV vicarious calibration
    Santer, RP
    Schmectig, C
    Thome, KJ
    ADVANCED AND NEXT-GENERATION SATELLITES II, 1997, 2957 : 344 - 354
  • [3] MERIS/ENVISAT vicarious calibration over land
    Kneubühler, M
    Schaepman, ME
    Thome, KJ
    Schläpfer, D
    SENSORS, SYSTEMS AND NEXT-GENERATION SATELLITES VII, 2004, 5234 : 614 - 623
  • [4] Vicarious Calibration of sUAS Microbolometer Temperature Imagery for Estimation of Radiometric Land Surface Temperature
    Torres-Rua, Alfonso
    SENSORS, 2017, 17 (07)
  • [5] Vicarious calibration correction of large FOV sensor using BRDF model based on UAV angular spectrum measurements
    Pan, Zhiqiang
    Zhang, Haoping
    Min, Xiangjun
    Xu, Zhaopeng
    JOURNAL OF APPLIED REMOTE SENSING, 2020, 14 (02)
  • [6] BRDF measurement and calculation for SBUV/2 radiance calibration test diffuser
    Wei, ZY
    Kelly, KW
    EARTH OBSERVING SYSTEMS IX, 2004, 5542 : 311 - 322
  • [7] Temporal, spatial, and spectral variability at the Ivanpah Playa vicarious calibration site
    Villa-Aleman, E
    Kurzeja, RJ
    Pendergast, MM
    ALGORITHMS AND TECHNOLOGIES FOR MULTISPECTRAL, HYPERSPECTRAL AND ULTRASPECTRAL IMAGERY IX, 2003, 5093 : 320 - 330
  • [8] Impact of BRDF Spatiotemporal Smoothing on Land Surface Albedo Estimation
    Yang, Jian
    Shuai, Yanmin
    Duan, Junbo
    Xie, Donghui
    Zhang, Qingling
    Zhao, Ruishan
    REMOTE SENSING, 2022, 14 (09)
  • [9] Absolute Radiometric Calibration Method Based on Surface Hyperspectral BRDF Model
    Zhao Chun-yan
    Zhang Yan-na
    Wei Wei
    Zhang Meng
    Chen Lin
    Zhang Lu
    Li Xin
    Zheng Xiao-bing
    ACTA PHOTONICA SINICA, 2019, 48 (05)
  • [10] In-lab system-level BRDF measurement method of calibration diffuser
    Li M.
    Zong X.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2017, 46 (01):