Combining Photoplethysmography and Ballistocardiography to Address Voluntary Head Movements in Heart Rate Monitoring

被引:4
|
作者
Lomaliza, Jean-Pierre [1 ]
Park, Hanhoon [1 ]
Billinghurst, Mark [2 ]
机构
[1] Pukyong Natl Univ, Dept Elect Engn, Busan 48513, South Korea
[2] Univ South Australia, Sch Informat Technol & Math Sci, Adelaide, SA 5001, Australia
基金
新加坡国家研究基金会;
关键词
Videos; Faces; Heart beat; Blood; Tracking; Lighting; Photoplethysmography; Heart rate estimation; photoplethysmography; ballistocardiography; face video; voluntary head movement; hybrid method; dynamic voting; video call; VIDEO; SYSTEM; EXTRACTION; PPG;
D O I
10.1109/ACCESS.2020.3045387
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Daily vital signs monitoring is very important for detecting diseases in early stages and for preventive treatments. Such a task can be achieved by taking advantage of the omnipresence of cameras in people's personal space. As heart-related diseases are part of the leading causes of deaths worldwide, monitoring heart-related vital signs appear to be very crucial. In this article we aim to provide a touchless approach and propose a robust method for estimating heart rate through analysis of face videos. In particular, we consider a challenging scenario, i.e., the user is on a video call and may often move his/her head. Existing touchless, vision-based methods use either photoplethysmography (PPG) or ballistocardiography (BCG). PPG methods exploit color changes in human skin during heartbeats caused by blood volume variations, but this is very sensitive to unstable lighting conditions. On the other hand, BCG methods exploit subtle head motions caused by Newtonian reaction to blood influx into the head at each heartbeat, thus being sensitive to a subject's voluntary head movements. Unlike conventional studies where either a PPG method or a BCG method is used, we propose to combine both to overcome the weakness faced by each method. We use BCG methods as the main approach due to their better accuracy on heart rate estimation, and PPG methods are used as the secondary backup to improve the accuracy in cases of large and frequent voluntary head movements. To this end, we introduce a dynamic voting system that effectively combines results of several variants of PPG and BCG methods. Experiments conducted on 20 healthy subjects with different skin tones in different lighting conditions show that our method has better accuracy compared to state-of-the-art methods, well addressing large voluntary head movements. Our method had a mean absolute error of 1.23 beats per minute (BPM) in the cases without voluntary head movements and 2.78 BPM in the cases with voluntary head movements.
引用
收藏
页码:226224 / 226239
页数:16
相关论文
共 50 条
  • [1] Contactless continuous heart rate monitoring system using ballistocardiography
    Sumali, Brian
    Mitsukura, Yasue
    Nishimura, Toshihiko
    [J]. PLOS ONE, 2022, 17 (07):
  • [2] Combining Adaptive Filter and Phase Vocoder for Heart Rate Monitoring Using Photoplethysmography During Physical Exercise
    Xie, Qingsong
    Zhang, Qirui
    Wang, Guoxing
    Lian, Yong
    [J]. 2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3568 - 3571
  • [3] Using photoplethysmography in heart rate monitoring of patients with epilepsy
    van Andel, Judith
    Ungureanu, Constantin
    Aarts, Ronald
    Leijten, Frans
    Arends, Johan
    [J]. EPILEPSY & BEHAVIOR, 2015, 45 : 142 - 145
  • [4] Development of a Smart Seat Cushion for Heart Rate Monitoring Using Ballistocardiography
    Malik, Ahmed R.
    Pilon, Laurel
    Boger, Jennifer
    [J]. 2019 22ND IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND ENGINEERING (IEEE CSE 2019) AND 17TH IEEE INTERNATIONAL CONFERENCE ON EMBEDDED AND UBIQUITOUS COMPUTING (IEEE EUC 2019), 2019, : 379 - 383
  • [5] Continuous heart rate monitoring in atrial fibrillation with multispectral photoplethysmography
    Devaki, V.
    Lakshmanan, Madan Kumar
    Aravindan, R.
    Dhandapani, V.E.
    Jayanthi, T.
    [J]. Sensors and Actuators A: Physical, 2024, 380
  • [6] Contactless and continuous monitoring of heart rate based on photoplethysmography on a mattress
    Wong, M. Y. M.
    Pickwell-MacPherson, E.
    Zhang, Y. T.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2010, 31 (07) : 1065 - 1074
  • [7] Green Light Photoplethysmography as a Substitute for Heart Rate Variability Monitoring
    Maeda, Yuka
    Sekine, Masaki
    Tamura, Toshiyo
    Mizutani, Koichi
    [J]. Advanced Biomedical Engineering, 2024, 13 : 301 - 306
  • [8] Photoplethysmography Heart Rate Monitoring: State-of-the-Art Design
    Feukeu, Etienne Alain
    Winberg, Simon
    [J]. INTERNATIONAL JOURNAL OF E-HEALTH AND MEDICAL COMMUNICATIONS, 2021, 12 (03) : 17 - 37
  • [9] Noncontact Monitoring of Heart Rate and Heart Rate Variability in Geriatric Patients Using Photoplethysmography Imaging
    Yu, Xinchi
    Laurentius, Thea
    Bollheimer, Cornelius
    Leonhardt, Steffen
    Antink, Christoph Hoog
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (05) : 1781 - 1792
  • [10] Heart rate monitoring via remote photoplethysmography with motion artifacts reduction
    Cennini, Giovanni
    Arguel, Jeremie
    Aksit, Kaan
    van Leest, Arno
    [J]. OPTICS EXPRESS, 2010, 18 (05): : 4867 - 4875