Development and feasibility study of a two-dimensional ultrasonic-measurement-integrated blood flow analysis system for hemodynamics in carotid arteries

被引:10
|
作者
Kato, Takaumi [1 ]
Funamoto, Kenichi [2 ]
Hayase, Toshiyuki [2 ]
Sone, Shusaku [1 ]
Kadowaki, Hiroko [3 ]
Shimazaki, Tadashi [4 ]
Jibiki, Takao [4 ]
Miyama, Koji [4 ]
Liu, Lei [4 ]
机构
[1] Tohoku Univ, Grad Sch Biomed Engn, Sendai, Miyagi 9808579, Japan
[2] Tohoku Univ, Inst Fluid Sci, Aoba Ku, Sendai, Miyagi 9808577, Japan
[3] Tohoku Univ, Grad Sch Engn, Sendai, Miyagi 9808579, Japan
[4] GE Healthcare Japan, Hino, Tokyo 1918503, Japan
关键词
Hemodynamics; Ultrasound color Doppler imaging; Computational fluid dynamics; Measurement-integrated simulation; Carotid artery; SHEAR-STRESS; IN-VIVO; SIMULATION; COMMON; BIFURCATION; PROFILES; MODELS; AORTA;
D O I
10.1007/s11517-014-1193-3
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Prevention and early detection of atherosclerosis are critical for protection against subsequent circulatory disease. In this study, an automated two-dimensional ultrasonic-measurement-integrated (2D-UMI) blood flow analysis system for clinical diagnosis was developed, and the feasibility of the system for hemodynamic analysis in a carotid artery was revealed. The system automatically generated a 2D computational domain based on ultrasound color Doppler imaging and performed a UMI simulation of blood flow field to visualize hemodynamics in the domain. In the UMI simulation, compensation of errors was applied by adding feedback signals proportional to the differences between Doppler velocities by measurement and computation while automatically estimating the cross-sectional average inflow velocity. The necessity of adjustment of the feedback gain was examined by analyzing blood flow in five carotid arteries: three healthy, one sclerosed, and one stenosed. The same feedback gain was generally applicable for the 2D-UMI simulation in all carotid arteries, depending on target variables. Thus, the present system was shown to be versatile in the sense that the parameter is patient independent. Moreover, the possibility of a new diagnostic method based on the hemodynamic information obtained by the 2D-UMI simulation, such as a waveform of the cross-sectional average inflow velocity and wall shear stress distributions, was suggested.
引用
收藏
页码:933 / 943
页数:11
相关论文
共 50 条
  • [1] Development and feasibility study of a two-dimensional ultrasonic-measurement-integrated blood flow analysis system for hemodynamics in carotid arteries
    Takaumi Kato
    Kenichi Funamoto
    Toshiyuki Hayase
    Shusaku Sone
    Hiroko Kadowaki
    Tadashi Shimazaki
    Takao Jibiki
    Koji Miyama
    Lei Liu
    Medical & Biological Engineering & Computing, 2014, 52 : 933 - 943
  • [2] Blood flow analysis in carotid artery bifurcation by two-dimensional ultrasonic-measurement-integrated simulation
    Graduate School of Engineering, Tohoku University, 6-6 Aramaki Aza Aoba, Aoba-ku, Sendai
    980-8579, Japan
    不详
    980-8577, Japan
    不详
    980-8579, Japan
    不详
    191-8503, Japan
    J. Biomech. Sci. Eng., 1 (1-14):
  • [3] Feasibility Verification of Blood Viscosity Estimation by Two-Dimensional Ultrasonic-Measurement-Integrated Blood Flow Analysis
    Kadowaki, Hiroko
    Kishimoto, Takuya
    Tokunaga, Takeshi
    Mori, Koji
    Saito, Takashi
    Journal of Engineering and Science in Medical Diagnostics and Therapy, 2021, 4 (02)
  • [4] TEMPORAL VARIATION CHARACTERISTICS OF ANALYSIS ACCURACY IN TWO-DIMENSIONAL ULTRASONIC-MEASUREMENT-INTEGRATED BLOOD FLOW ANALYSIS
    Kadowaki, Hiroko
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 3, 2017,
  • [5] EFFECT OF FEEDBACK CONDITIONS ON BLOOD VISCOSITY ESTIMATION METHOD IN TWO-DIMENSIONAL ULTRASONIC-MEASUREMENT-INTEGRATED BLOOD FLOW ANALYSIS
    Kishimoto, Takuya
    Kadowaki, Hiroko
    Tokunaga, Takeshi
    Mori, Koji
    Saito, Takashi
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 3, 2020,
  • [6] Study of Estimation Method for Unsteady Inflow Velocity in Two-Dimensional Ultrasonic-Measurement-Integrated Blood Flow Simulation
    Kadowaki, Hiroko
    Hayase, Toshiyuki
    Funamoto, Kenichi
    Taniguchi, Nobuyuki
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (02) : 403 - 414
  • [7] Photoplethysmography and ultrasonic-measurement-integrated simulation to clarify the relation between two-dimensional unsteady blood flow field and forward and backward waves in a carotid artery
    Shusaku Sone
    Toshiyuki Hayase
    Kenichi Funamoto
    Atsushi Shirai
    Medical & Biological Engineering & Computing, 2017, 55 : 719 - 731
  • [8] Photoplethysmography and ultrasonic-measurement-integrated simulation to clarify the relation between two-dimensional unsteady blood flow field and forward and backward waves in a carotid artery
    Sone, Shusaku
    Hayase, Toshiyuki
    Funamoto, Kenichi
    Shirai, Atsushi
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (05) : 719 - 731
  • [9] Development of ultrasonic-measurement-integrated simulation system for complex blood flows
    Yamagata, Takayuki
    Hayase, Toshiyuki
    FUTURE MEDICAL ENGINEERING BASED ON BIONANOTECHNOLOGY, PROCEEDINGS, 2006, : 1045 - +
  • [10] Simultaneous Analysis System for Blood Pressure and Flow Using Photoplethysmography and Ultrasonic-Measurement-Integrated Simulation
    Sone, Shusaku
    Hayase, Toshiyuki
    Funamoto, Kenichi
    Shirai, Atsushi
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1827 - 1830