Coronary artery magnetic resonance angiography (MRA):: A comparison between the whole-heart and volume-targeted methods using a T2-prepared SSFP sequence

被引:30
|
作者
Bi, Xiaoming
Deshpande, Vibhas
Carr, James
Li, Debiao
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[3] Siemens Med Solut, Erlangen, Germany
关键词
magnetic resonance angiography (MRA); coronary arteries; steady-state free precession; navigator-gated; three-dimensional;
D O I
10.1080/10976640600723706
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study, coronary MRA was performed on 10 healthy volunteers using the whole-heart and volume-targeted scans with comparable imaging parameters. Similar results in the SNR, CNR, and vessel diameter were observed. The depicted length of coronary arteries was longer using the whole-heart scan (whole-heart: RCA/LAD = 13.4 +/- 3.9/10.5 +/- 1.6 cm; volume-targeted: RCA/LAD = 11.0 +/- 2.6/8.7 +/- 1.8 cm). Imaging times for the RCA- (3.8 +/- 1.4 minutes) and LAD-targeted (3.6 +/- 1.3 minutes) are similar, while the time required for one whole-heart scan is significantly longer (12.2 +/- 4.0 minutes). The measured vessel sharpness was higher using the volume-targeted method (whole-heart: RCA/LAD = 0.65 +/- 0.18/0.78 +/- 0.16; volume-targeted: RCA/LAD = 0.84 +/- 0.22/0.90 +/-0.20). Combination of the whole-heart and volume-targeted methods could be potentially useful in clinical applications of coronary MRA.
引用
收藏
页码:703 / 707
页数:5
相关论文
共 50 条
  • [1] Volume-Targeted and Whole-Heart Coronary Magnetic Resonance Angiography Using an Intravascular Contrast Agent
    Tang, Lijun
    Merkle, Nico
    Schaer, Michael
    Korosoglou, Grigorios
    Solaiyappan, Meiyappan
    Hombach, Vinzenz
    Stuber, Matthias
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 1191 - 1196
  • [2] Noninvasive test of nitrate-induced coronary vasomotion by 1.5-T whole-heart 3D magnetic resonance angiography using a T2-prepared SSFP sequence
    Hang Jin
    Meng-Su Zeng
    Hong Yun
    Mei-Ying Ge
    Jian-Ying Ma
    Shan Yang
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1707 - 1716
  • [3] Noninvasive test of nitrate-induced coronary vasomotion by 1.5-T whole-heart 3D magnetic resonance angiography using a T2-prepared SSFP sequence
    Jin, Hang
    Zeng, Meng-Su
    Yun, Hong
    Ge, Mei-Ying
    Ma, Jian-Ying
    Yang, Shan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07): : 1707 - 1716
  • [4] 3D coronary MR angiography at 1.5 T: Volume-targeted versus whole-heart acquisition
    Jin, Hang
    Zeng, Meng-Su
    Ge, Mei-Ying
    Yun, Hong
    Yang, Shan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (03) : 594 - 602
  • [5] Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography
    Sakuma, Hajime
    Ichikawa, Yasutaka
    Chino, Shuji
    Hirano, Tadanori
    Makino, Katsutoshi
    Takeda, Kan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) : 1946 - 1950
  • [6] Whole-Heart Coronary Angiography using Volume Computed Tomography in Comparison to Conventional Coronary Angiography
    Dewey, Marc
    Zimmermann, Elike
    Deissenrieder, Florian
    Laule, Michael
    Duebel, Hans-Peter
    Rutsch, Wolfgang
    Hamm, Bernd
    CIRCULATION, 2008, 118 (18) : S1006 - S1006
  • [7] Whole-heart coronary magnetic resonance angiography: Value for the detection of coronary artery stenoses in comparison to multislice computed tomography angiography
    Maintz, D.
    Ozgun, M.
    Hoffmeier, A.
    Quante, M.
    Fischbach, R.
    Manning, W. J.
    Heindel, W.
    Botnar, R. M.
    ACTA RADIOLOGICA, 2007, 48 (09) : 967 - 973
  • [8] Anomalous origin of the right coronary artery: Depiction at whole-heart coronary magnetic resonance angiography
    Sato, Yuichi
    Matsumoto, Naoya
    Komatsu, Sei
    Kunimasa, Taeko
    Yoda, Shunichi
    Tani, Shigemasa
    Kunimoto, Satoshi
    Achenbach, Stephan
    Saito, Satoshi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 127 (02) : 274 - 275
  • [9] Unenhanced Whole-Heart Coronary MRA: Prospective Intraindividual Comparison of 1.5-T SSFP and 3-T Dixon Water-Fat Separation GRE Methods Using Coronary Angiography as Reference
    Tian, Di
    Zhao, Shi-hai
    Wang, Yi
    Lu, Hong-fei
    Chen, Yin-yin
    Guo, Jia-jun
    Ma, Jian-ying
    Chen, Zhang-wei
    Zeng, Meng-su
    Jin, Hang
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (02) : 199 - 211
  • [10] Whole-heart coronary magnetic resonance angiography of double left anterior descending artery
    Kunimoto, Satoshi
    Sato, Yuichi
    Matsumoto, Naoya
    Kunimasa, Taeko
    Takayama, Tadateru
    Kasama, Shu
    Yoda, Shunichi
    Saito, Satoshi
    Hirayama, Atsushi
    HEART AND VESSELS, 2008, 23 (05) : 363 - 365