Dose Reduction Efforts for Pediatric Head CT Imaging in Washington State Trauma Centers: Follow-Up Survey Results

被引:9
|
作者
Graves, Janessa M. [1 ,2 ]
Kanal, Kalpana M. [1 ,3 ]
Rivara, Frederick P. [1 ,2 ,4 ]
Jarvik, Jeffrey G. [3 ,5 ,6 ,7 ,8 ]
Vavilala, Monica S. [1 ,2 ,9 ]
机构
[1] Univ Washington, Harborview Injury Prevent & Res Ctr, Seattle, WA 98104 USA
[2] Univ Washington, Sch Med, Dept Pediat, Seattle, WA 98104 USA
[3] Univ Washington, Sch Med, Dept Radiol, Seattle, WA 98104 USA
[4] Univ Washington, Sch Publ Hlth, Dept Epidemiol, Seattle, WA 98104 USA
[5] Univ Washington, Sch Publ Hlth, Comparat Effectiveness Cost & Outcomes Res Ctr, Seattle, WA 98104 USA
[6] Univ Washington, Sch Med, Dept Neurol Surg, Seattle, WA 98104 USA
[7] Univ Washington, Sch Publ Hlth, Dept Hlth Serv, Seattle, WA 98104 USA
[8] Univ Washington, Sch Pharm, Dept Pharm, Seattle, WA 98104 USA
[9] Univ Washington, Sch Pharm, Dept Anesthesiol & Pain Med, Seattle, WA 98104 USA
关键词
CT imaging protocols; pediatric head CT; trauma center; radiation dose; Washington State; ATOMIC-BOMB SURVIVORS; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; GENTLY CAMPAIGN; UNITED-STATES; CHILDREN; PROTOCOLS; QUALITY; PROGRAM; SCANS;
D O I
10.1016/j.jacr.2013.07.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine variation in pediatric trauma head CT imaging protocols in Washington State trauma centers (TCs) in 2012 and compare to a previous survey conducted in 2008-2009. Methods: A mixed-mode (online and paper) survey was sent to all adult and pediatric Washington State TCs (levels 1-5). Respondents provided information about the CT scanner used for pediatric head scans and technical information about pediatric dose reduction protocols. Mean head effective dose and organ dose for a female baby were estimated. Results were compared with previous data. Results: Sixty-one of 76 TCs responded to the 2012 survey (response rate, 80.3%, versus 76% for 20082009 survey). In 2012, 91.7% reported having a dedicated pediatric protocol (87.7% in 2008-2009). Protective shielding use ranged from 80% to 100% across both survey years. In 2012, 2.5 times more TCs provided sufficient information to conduct dose calculations than in 2008-2009. Estimated mean CT dose index was 23.1 milliGray (mGy) in 2012, compared with 34.8 mGy in 2008-2009 (P = .01). Estimated mean dose length product was also significantly lower in 2012 than 2008-2009 (307.6 mGy x cm versus 430.1 mGy x cm, respectively; P = .04). Wide variation in mean effective dose was observed for level 3 and 4 TCs in 2012, similar to variation observed in 2008-2009 among level 4 TCs. Mean organ dose was significantly lower in 2012 for eye lens and brain, but higher for thyroid than in 2008-2009 (P < .05). Conclusions: Although most Washington State TCs employ dose reduction protocols for pediatric head CTs, and some measures were lower in 2012, variation in protocols use and estimated dose continues to exist. More complete responses in 2012 suggest improved understanding of the importance of pediatric dose reduction efforts. Education and institutional protocols are necessary to reduce pediatric radiation dose from head CTs.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 50 条
  • [1] Pediatric mild head trauma: is outpatient follow-up imaging necessary or beneficial?
    Shimony, Nir
    Dailey, Travis
    Barrow, David
    Bui, Anh
    Noureldine, Mohammad Hassan A.
    Martinez-Sosa, Meleine
    Rodriguez, Luis F.
    Carey, Carolyn M.
    Tuite, Gerald F.
    Jallo, George, I
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2021, 28 (01) : 62 - 68
  • [2] Variation in Pediatric Head CT Imaging Protocols in Washington State
    Kanal, Kalpana M.
    Vavilala, Monica S.
    Raelson, Colin
    Mohan, Abhishek
    Cohen, Wendy
    Jarvik, Jeffrey
    Rivara, Frederick P.
    Stewart, Brent K.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2011, 8 (04) : 242 - 250
  • [3] Follow-Up Computed Tomography Requirement of Pediatric Head Trauma Patients with Abnormal Imaging Findings
    Yilmaz, Hakan
    Yilmaz, Ozlem
    WORLD NEUROSURGERY, 2019, 124 : E764 - E768
  • [4] The value of routine follow-up imaging in pediatric blunt liver trauma
    Navarro, OM
    Babyn, PS
    Pearl, RH
    RADIOLOGY, 1998, 209P : 480 - 480
  • [5] The value of routine follow-up imaging in pediatric blunt liver trauma
    Oscar Navarro
    P. S. Babyn
    Richard H. Pearl
    Pediatric Radiology, 2000, 30 : 546 - 550
  • [6] The value of routine follow-up imaging in pediatric blunt liver trauma
    Navarro, O
    Babyn, PS
    Pearl, RH
    PEDIATRIC RADIOLOGY, 2000, 30 (08) : 546 - 550
  • [7] AN ANALYSIS OF SCHEDULED FOLLOW-UP COMPUTED TOMOGRAPHY (CT) SCANS IN PEDIATRIC TRAUMA PATIENTS WITH CLOSED HEAD INJURIES
    Duthie, Susan
    Harvey, Helen
    Bush, Ruth
    Levy, Michael
    Hilfiker, Mary
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U204 - U204
  • [8] Outcomes of Follow-up Imaging After Pediatric Spinal Trauma Confirmed With Magnetic Resonance Imaging
    Siren, Aapo
    Syvanen, Johanna
    Nyman, Mikko
    Mattila, Kimmo
    Hirvonen, Jussi
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2024, 44 (04) : e329 - e334
  • [9] Behavioral Health Screening and Follow-Up Services in Pediatric Trauma Centers Across the United States
    Ridings, Leigh E.
    Espeleta, Hannah C.
    Litvitskiy, Nicole
    Higgins, Kristen
    Bravoco, Olivia
    Davidson, Tatiana M.
    Streck, Christian J.
    Kassam-Adams, Nancy
    Ruggiero, Kenneth J.
    JOURNAL OF PEDIATRIC PSYCHOLOGY, 2023, : 960 - 969
  • [10] Radiation Dose Reduction for Pulmonary Nodule Follow-Up on Subsequent Chest CT
    Gallardo, L.
    Tien, H.
    Farah, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)