A simple but reliable method for measuring 3D Achilles tendon moment arm geometry from a single, static magnetic resonance scan

被引:12
|
作者
Alexander, C. F. [1 ]
Lum, I. [1 ]
Reid, S. [1 ]
Clarke, E. [2 ,3 ]
Stannage, K. [4 ]
El-Sallam Abd, A. [1 ]
Herbert, R. D. [5 ,6 ]
Donnelly, C. J. [1 ]
机构
[1] Univ Western Australia, Sch Sport Sci Exercise & Hlth, M408,35 Stirling Highway, Perth, WA, Australia
[2] Univ Sydney, Sydney Med Sch, Sydney, NSW, Australia
[3] Kolling Inst Med Res, Sydney, NSW, Australia
[4] Princess Margaret Hosp, Dept Orthopaed Surg, Perth, WA, Australia
[5] Neurosci Res Australia, Sydney, NSW, Australia
[6] Univ New South Wales, Sydney, NSW, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
In vivo; MRI; Ankle; Talocrural; Musculoskeletal; Modelling; VIVO; SUBTALAR;
D O I
10.1016/j.jbiomech.2017.01.038
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Current methods for measuring in vivo 3D muscle-tendon moment arms generally rely on the acquisition of magnetic resonance imaging (MRI) scans at multiple joint angles. However, for patients with musculoskeletal pathologies such as fixed contractures, moving a joint through its full range of motion is not always feasible. The purpose of this research was to develop a simple, but reliable in vivo 3D Achilles tendon moment arm (ATMA) technique from a single static MRI scan. To accomplish this, for nine healthy adults (5 males, 4 females), the geometry of a cylinder was fit to the 3D form of the talus dome, which was used to estimate the talocrural flexion/extension axis, and a fifth-order polynomial fit to the line of action of the Achilles tendon. The single static scan in vivo 3D ATMA estimates were compared to estimates obtained from the same subjects at the same ankle joint angles using a previously validated 3D dynamic MRI based in vivo ATMA measurement technique. The ATMA estimates from the single scan in vivo 3D method (52.5 mm +/- 5.6) were in excellent agreement (ICC = 0.912) to the validated in vivo 3D method (51.5 mm +/- 5.1). These data show reliable in vivo 3D ATMA can be obtained from a single MRI scan for healthy adult populations. The single scan, in vivo 3D ATMA technique provides researchers with a simple, but reliable method for obtaining subject-specific ATMAs for musculoskeletal modelling purposes. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:134 / 138
页数:5
相关论文
共 11 条
  • [1] The 3D in vivo Achilles' tendon moment arm, quantified during active muscle control and compared across sexes
    Sheehan, Frances T.
    JOURNAL OF BIOMECHANICS, 2012, 45 (02) : 225 - 230
  • [2] A non-invasive, 3D, dynamic MRI method for measuring muscle moment arms in vivo: Demonstration in the human ankle joint and Achilles tendon
    Clarke, E. C.
    Martin, J. H.
    d'Entremont, A. G.
    Pandy, M. G.
    Wilson, D. R.
    Herbert, R. D.
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (01) : 93 - 99
  • [3] MAGNETIC RESONANCE IMAGING AND FREEHAND 3-D ULTRASOUND PROVIDE SIMILAR ESTIMATES OF FREE ACHILLES TENDON SHAPE AND 3-D GEOMETRY
    Devaprakash, Daniel
    Lloyd, David G.
    Barrett, Rod S.
    Obst, Steven J.
    Kennedy, Ben
    Adams, Kahlee L.
    Hunter, Adam
    Vlahovich, Nicole
    Pease, David L.
    Pizzolato, Claudio
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (11): : 2898 - 2905
  • [4] A Simple Structural Magnetic Resonance Imaging (MRI) Method for 3D Mapping between Head Skin Tattoos and Brain Landmarks
    Semework, Mulugeta
    26TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE: SBEC 2010, 2010, 32 : 493 - 495
  • [5] Physical model from 3D ultrasound and magnetic resonance imaging scan data reconstruction of lumbosacral myelomeningocele in a fetus with Chiari II malformation
    Werner, Heron
    Lopes, Jorge
    Tonni, Gabriele
    Araujo Junior, Edward
    CHILDS NERVOUS SYSTEM, 2015, 31 (04) : 511 - 513
  • [6] Physical model from 3D ultrasound and magnetic resonance imaging scan data reconstruction of lumbosacral myelomeningocele in a fetus with Chiari II malformation
    Heron Werner
    Jorge Lopes
    Gabriele Tonni
    Edward Araujo Júnior
    Child's Nervous System, 2015, 31 : 511 - 513
  • [7] Normative healthy reference values for global and segmental 3D principal and geometry dependent strain from cine cardiac magnetic resonance imaging
    Guzzardi, David G.
    White, James A.
    Labib, Dina
    Dykstra, Steven
    Flewitt, Jacqueline
    Feuchter, Patricia
    Sandonato, Rosa
    Howarth, Andrew G.
    Lydell, Carmen P.
    Fine, Nowell M.
    Greiner, Russel
    Satriano, Alessandro
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (01): : 115 - 134
  • [8] Normative healthy reference values for global and segmental 3D principal and geometry dependent strain from cine cardiac magnetic resonance imaging
    David G. Guzzardi
    James A. White
    Dina Labib
    Steven Dykstra
    Jacqueline Flewitt
    Patricia Feuchter
    Rosa Sandonato
    Andrew G. Howarth
    Carmen P. Lydell
    Nowell M. Fine
    Russel Greiner
    Alessandro Satriano
    The International Journal of Cardiovascular Imaging, 2023, 39 : 115 - 134
  • [9] A novel quantification method for cervical spinal cord volume in multiple sclerosis patients from 3D magnetic; Resonance images
    Evangelou, Lordanis E.
    Sonkova, Pavlina
    Gallo, Antonio
    Ohayon, Joan M.
    Cantor, Fredric
    McFarland, Henry
    Bagnato, Francesca
    NEUROLOGY, 2008, 70 (11) : A469 - A470
  • [10] Correcting multi material artifacts from single material phase retrieved holo-tomograms with a simple 3D Fourier method
    Ullherr, Maximilian
    Zabler, Simon
    OPTICS EXPRESS, 2015, 23 (25): : 32718 - 32727