Automated Assessment of Whole-Body Adipose Tissue Depots From Continuously Moving Bed MRI: A Feasibility Study

被引:70
|
作者
Kullberg, Joel [1 ]
Johansson, Lars [1 ,2 ]
Ahlstrom, Hakan [1 ]
Courivaud, Frederic [3 ]
Koken, Peter [4 ]
Eggers, Holger [4 ]
Boernert, Peter [4 ]
机构
[1] Uppsala Univ, Dept Radiol, Uppsala, Sweden
[2] AstraZeneca R&D, Molndal, Sweden
[3] Philips Healthcare, MR Clin Sci, Oslo, Norway
[4] Philips Res Europe, Hamburg, Germany
基金
瑞典研究理事会;
关键词
magnetic resonance imaging; whole-body; water-fat imaging; visceral adipose tissue; subcutaneous adipose tissue; automated segmentation; UNSUPERVISED ASSESSMENT; ABDOMINAL FAT; DECOMPOSITION; SEGMENTATION; IMPROVES; OBESITY; WATER; IDEAL;
D O I
10.1002/jmri.21820
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present an automated algorithm for segmentation of visceral, subcutaneous, and total volumes of adipose tissue depots (VAT, SAT, TAT) from whole-body MRI data sets and to investigate the VAT segmentation accuracy and the reproducibility of all depot assessments. Materials and Methods: Repeated measurements were performed on 24 volunteer subjects using a 1.5 Testa clinical MRI scanner and a three-dimensional (3D) multi-gradient-echo sequence (resolution: 2.1 x 2.1 x 8 mm(3), acquisition time: 5 min 15 s). Fat and water images were reconstructed. and fully automated segmentation was performed. Manual segmentation of the VAT reference was performed by an experienced operator. Results: Strong correlation (R = 0.999) was found between the automated and manual VAT assessments. The automated results underestimated VAT with 4.7 +/- 4.4%. The accuracy was 88 +/- 4.5% and 7.6 +/- 5.7% for true positive and false positive fractions, respectively. Coefficients of variation front the repeated measurements were: 2.32% +/- 2.61%, 2.25% +/- 2.10%, and 1.01% +/- 0.74% for VAT, SAT, and TAT, respectively. Conclusion: Automated and manual VAT results correlated strongly. The assessments of all depots were highly reproducible. The acquisition and postprocessing techniques presented are likely useful in obesity related studies.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [1] Principles of whole-body continuously-moving-table MRI
    Boernert, Peter
    Aldefeld, Bernd
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) : 1 - 12
  • [2] Whole-Body Continuously Moving Table MRI: Principles and Applications
    Ludwig U.
    Börnert P.
    eMagRes, 2010, 2010
  • [3] Automated Quantification of Adipose and Skeletal Muscle Tissue in Whole-Body MRI Data for Epidemiological Studies
    Wald, Diana
    Teucher, Birgit
    Dinkel, Julien
    Kaaks, Rudolf
    Delorme, Stefan
    Meinzer, Hans-Peter
    Heimann, Tobias
    MEDICAL IMAGING 2012: COMPUTER-AIDED DIAGNOSIS, 2012, 8315
  • [4] Subcutaneous Adipose Tissue Segmentation in Whole-Body MRI of Children
    Fouquier, Geoffroy
    Anquez, Jeremie
    Bloch, Isabelle
    Falip, Celine
    Adamsbaum, Catherine
    PROGRESS IN PATTERN RECOGNITION, IMAGE ANALYSIS, COMPUTER VISION, AND APPLICATIONS, 2011, 7042 : 97 - +
  • [5] Effects of a Weight Loss Intervention on Adipose Tissue Depots Using Whole-Body MRI in Adults with Type 2 Diabetes
    Gallagher, Dympna
    Kelley, David
    Pi-Sunyer, Xavier
    Heshka, Stanley
    OBESITY, 2008, 16 : S90 - S90
  • [6] WHOLE-BODY MRI-BASED ASSESSMENT OF ADIPOSE TISSUE: RECOMMENDATIONS FOR DATA ACQUISITION AND PROCESSING
    Kovacova, Veronika
    Cuta, Martin
    Jurda, Mikolas
    Bezdekova, Vendula
    Cerny, Dominik
    Jandova, Marie
    Urbanova, Petra
    ANTHROPOLOGIE-INTERNATIONAL JOURNAL OF HUMAN DIVERSITY AND EVOLUTION, 2023, 61 (01): : 109 - 117
  • [7] Standardized assessment of whole body adipose tissue topography by MRI
    Machann, J
    Thamer, C
    Schnoedt, B
    Haap, M
    Haring, HU
    Claussen, CD
    Stumvoll, M
    Fritsche, A
    Schick, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) : 455 - 462
  • [8] Assessment of adipose tissue from whole body 3T MRI scans
    Song, Ting
    An, Jing
    Chen, Qun
    Lee, Vivian
    Laine, Andrew
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 7012 - 7015
  • [9] Rapid automated measurement of body fat distribution from whole-body MRI
    Brennan, DD
    Whelan, PF
    Robinson, K
    Ghita, O
    O'Brien, JM
    Sadleir, R
    Eustace, SJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (02) : 418 - 423
  • [10] Segmentation and evaluation of adipose tissue from whole body MRI scans
    Jin, YP
    Imielinska, CZ
    Laine, AF
    Udupa, J
    Shen, W
    Heymsfield, SB
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 1, 2003, 2878 : 635 - 642