Fast simultaneous noncontrast angiography and intraplaque hemorrhage (fSNAP) sequence for carotid artery imaging

被引:11
|
作者
Chen, Shuo [1 ]
Ning, Jia [1 ]
Zhao, Xihai [1 ]
Wang, Jinnan [2 ]
Zhou, Zechen [1 ]
Yuan, Chun [1 ,3 ]
Chen, Huijun [1 ]
机构
[1] Tsinghua Univ, Sch Med, Dept Biomed Engn, Ctr Biomed Imaging Res, Beijing, Peoples R China
[2] Philips Res North Amer, Clin Sites Res Program, Briarcliff Manor, NY USA
[3] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
carotid artery; MR angiography; intraplaque hemorrhage; phase-sensitive; SNAP; SENSITIVE INVERSION-RECOVERY; MAGNETIC-RESONANCE; PHASE-CORRECTION; PLAQUE; MRI; RECONSTRUCTION; ASSOCIATION; RESOLUTION; CONTRAST; EVENTS;
D O I
10.1002/mrm.26111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo propose a fast simultaneous noncontrast angiography and intraplaque hemorrhage (fSNAP) sequence for carotid artery imaging. MethodsThe proposed fSNAP sequence uses a low-resolution reference acquisition for phase-sensitive reconstruction to speed up the scan, and an inversion recovery acquisition with arbitrary k-space filling order to generate similar contrast to conventional SNAP. Four healthy volunteers and eight patients were recruited to test the performance of fSNAP in vivo. The lumen area quantification, muscle-blood CNR, IPH-blood CNR, lumen SNR, and standard deviation and intraplaque hemorrhage (IPH) detection accuracy were compared between fSNAP and SNAP. ResultsBy using a low-resolution reference acquisition with 1/4 matrix size of the full-resolution reference scan, the scan time of fSNAP was 37.5% less than that of SNAP. A high agreement of lumen area measurement (ICC=0.97, 95% CI: 0.96-0.99) and IPH detection (Kappa=1) were found between fSNAP and SNAP. Also, no significant difference was found for muscle-blood CNR (P=0.25), IPH-blood CNR (P=0.35), lumen SNR (P=0.60), and standard deviation (P=0.46) between the two techniques. ConclusionThe feasibility of fSNAP was validated. fSNAP can improve the imaging efficiency with similar performance to SNAP on carotid artery imaging. Magn Reson Med 77:753-758, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:753 / 758
页数:6
相关论文
共 50 条
  • [1] Simultaneous noncontrast angiography and intraPlaque hemorrhage (SNAP) imaging for carotid atherosclerotic disease evaluation
    Wang, Jinnan
    Boernert, Peter
    Zhao, Huilin
    Hippe, Daniel S.
    Zhao, Xihai
    Balu, Niranjan
    Ferguson, Marina S.
    Hatsukami, Thomas S.
    Xu, Jianrong
    Yuan, Chun
    Kerwin, William S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 337 - 345
  • [2] Simultaneous Noncontrast Angiography and Intraplaque Hemorrhage (SNAP) Imaging: Comparison With Contrast-Enhanced MR Angiography for Measuring Carotid Stenosis
    Shu, Hongge
    Sun, Jie
    Hatsukami, Thomas S.
    Balu, Niranjan
    Hippe, Daniel S.
    Liu, Haining
    Kohler, Ted R.
    Zhu, Wenzhen
    Yuan, Chun
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (04) : 1045 - 1052
  • [3] Characterization of Craniocervical Artery Dissection by Simultaneous MR Noncontrast Angiography and Intraplaque Hemorrhage Imaging at 3T
    Li, Q.
    Wang, J.
    Chen, H.
    Gong, X.
    Ma, N.
    Gao, K.
    He, L.
    Guan, M.
    Chen, Z.
    Li, R.
    Mi, D.
    Yuan, C.
    Zhao, X.
    Zhao, X. H.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (09) : 1769 - 1775
  • [4] Histological validation of simultaneous non-contrast angiography and intraplaque hemorrhage imaging (SNAP) for characterizing carotid intraplaque hemorrhage
    Li, Dongye
    Qiao, Huiyu
    Han, Yongjun
    Han, Hualu
    Yang, Dandan
    Cao, Jingli
    Xu, Huimin
    Wang, Tao
    Wang, Yajie
    Shen, Jun
    Zhao, Xihai
    [J]. EUROPEAN RADIOLOGY, 2021, 31 (05) : 3106 - 3115
  • [5] Histological validation of simultaneous non-contrast angiography and intraplaque hemorrhage imaging (SNAP) for characterizing carotid intraplaque hemorrhage
    Dongye Li
    Huiyu Qiao
    Yongjun Han
    Hualu Han
    Dandan Yang
    Jingli Cao
    Huimin Xu
    Tao Wang
    Yajie Wang
    Jun Shen
    Xihai Zhao
    [J]. European Radiology, 2021, 31 : 3106 - 3115
  • [6] Evaluation of Carotid Atherosclerotic Plaque Surface Characteristics Utilizing Simultaneous Noncontrast Angiography and Intraplaque Hemorrhage (SNAP) Technique
    Chen, Shuo
    Zhao, Huilin
    Li, Jifan
    Zhou, Zechen
    Li, Rui
    Balu, Niranjan
    Yuan, Chun
    Chen, Huijun
    Zhao, Xihai
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (03) : 634 - 639
  • [7] One-step evaluation of intraplaque hemorrhage in the carotid artery and vertebrobasilar artery using simultaneous non-contrast angiography and intraplaque hemorrhage
    Kim, Min Jee
    Kwak, Hyo Sung
    Hwang, Seung Bae
    Chung, Gyung Ho
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2021, 141
  • [8] Plaque components segmentation in carotid artery on simultaneous non-contrast angiography and intraplaque hemorrhage imaging using machine learning
    Zhang, Qiang
    Qiao, Huiyu
    Dou, Jiaqi
    Sui, Binbin
    Zhao, Xihai
    Chen, Zhensen
    Wang, Yishi
    Chen, Shuo
    Lin, Mingquan
    Chiu, Bernard
    Yuan, Chun
    Li, Rui
    Chen, Huijun
    [J]. MAGNETIC RESONANCE IMAGING, 2019, 60 : 93 - 100
  • [9] Simultaneous intracranial angiography and intraplaque hemorrhage imaging using SNAP
    Jinnan Wang
    Xihai Zhao
    Peter Boernert
    Chun Yuan
    [J]. Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [10] Evaluation of Plaque Vulnerability via Combination of Hemodynamic Analysis and Simultaneous Non-Contrast Angiography and Intraplaque Hemorrhage (SNAP) Sequence for Carotid Intraplaque Hemorrhage
    Lee, Ui Yun
    Kwak, Hyo Sung
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (09):