An interactive application for removal of bone information in CT-angiography

被引:7
|
作者
Maksimov, D [1 ]
Finkel, F [1 ]
Dietz, T [1 ]
Diehl, S [1 ]
Düber, C [1 ]
Rebholz, P [1 ]
Hesser, J [1 ]
Männer, R [1 ]
机构
[1] Univ Mannheim, ICM, Mannheim, Germany
关键词
D O I
10.1109/CBMS.2004.1311746
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper we present a method that allows removing bony structures and. calcifications from CT angiography (CTA) data. It relies on two data sets, one with (CA) and one without (NCA) contrast agent. In contrast to current approaches, the algorithm uses local rigid matching of each single object. Therefore, it allows compensating motion of the patient during acquisition. Furthermore, the method uses a highly accurate surface-matching procedure so that local mismatches can be as small as 3 voxels and therefore even arteries near the bone are mostly separated correctly. The overall system requires about 20 minutes on a Pentium 4 2.4 GHz with 1 GByte RAM for a 700 MByte data set (CA+NCA) and is currently used in the clinic for evaluation purposes.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
  • [1] Bone segmentation in CT-angiography data using a probabilistic atlas
    Straka, M
    LaCruz, A
    Köchl, A
    Dimitrov, LI
    Srámek, M
    Fleischmann, D
    Gröller, E
    VISION, MODELING, AND VISUALIZATION 2003, 2003, : 505 - 512
  • [2] SPIRAL CT-ANGIOGRAPHY OF THE AORTA
    BALM, R
    EIKELBOOM, BC
    VANLEEUWEN, MS
    NOORDZIJ, J
    EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (05): : 544 - 551
  • [3] Useful tips for CT-angiography
    Fernandez, G. C.
    Velasco, M.
    Delgado, C.
    Vazquez, M.
    Vilar, M.
    Tardaguila, F.
    RADIOLOGIA, 2008, 50 (04): : 285 - 296
  • [4] CT-Angiography - Cost Efficiency and Workflow
    不详
    GEFASSCHIRURGIE, 2013, 18 (04): : 248 - 249
  • [5] Multislice CT-angiography (MSCTA) of the hand
    Rieger, M
    Czermak, BV
    Bale, RJ
    Pechlaner, S
    Gabl, M
    Jaschke, WR
    RADIOLOGY, 2001, 221 : 121 - 121
  • [6] CT-Angiography of aneurysms: Certitudes and controversies
    Tamarozzi, R
    Ceruti, S
    Calzolari, F
    Saletti, A
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 133 - 136
  • [7] Preoperative CT-Angiography in Autologous Breast Reconstruction
    Vargas, Christina R.
    Koolen, Pieter G.
    Tobias, Adam M.
    Lin, Sam J.
    Lee, Bernard T.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2015, 221 (04) : S118 - S118
  • [8] Coronary CT-Angiography: Advent of Anatomic Imaging
    Schmermund, Axel
    Eckert, Joachim
    Schmidt, Marco
    Magedanz, Annett
    Voigtlaender, Thomas
    AKTUELLE KARDIOLOGIE, 2020, 9 (03) : 268 - 274
  • [9] PREOPERATIVE CT-ANGIOGRAPHY IN AUTOLOGOUS BREAST RECONSTRUCTION
    Vargas, Christina R.
    Koolen, Pieter G. L.
    Ho, Olivia A.
    Tobias, Adam M.
    Lin, Samuel J.
    Lee, Bernard T.
    MICROSURGERY, 2016, 36 (08) : 623 - 627
  • [10] The VesselGlyph:: Focus & context visualization in CT-angiography
    Straka, M
    Cervenansky, M
    La Cruz, A
    Köchl, A
    Srámek, M
    Gröller, E
    Fleischmann, D
    IEEE VISUALIZATION 2004, PROCEEEDINGS, 2004, : 385 - 392