Validating EEG source imaging using intracranial electrical stimulation

被引:7
|
作者
Unnwongse, Kanjana [1 ,8 ]
Rampp, Stefan [2 ,3 ]
Wehner, Tim [1 ]
Kowoll, Annika [1 ]
Parpaley, Yaroslav [4 ]
von Lehe, Marec [4 ]
Lanfer, Benjamin [1 ]
Rusiniak, Mateusz [5 ]
Wolters, Carsten [6 ,7 ]
Wellmer, Joerg [1 ]
机构
[1] Ruhr Univ Bochum, Univ Hosp Knappschaftskrankenhaus, Dept Neurol, Ruhr Epileptol, D-44892 Bochum, Germany
[2] Univ Hosp Erlangen, Dept Neurosurg, D-91054 Erlangen, Germany
[3] Univ Hosp Halle Saale, Dept Neurosurg, D-06120 Halle, Germany
[4] Ruhr Univ, Univ Hosp Knappschaftskrankenhaus, Dept Neurosurg, D-44892 Bochum, Germany
[5] Besa GmbH, D-82166 Grafelfing, Germany
[6] Univ Munster, Inst Biomagnetism & Biosignalanal, D-48149 Munster, Germany
[7] Univ Munster, Otto Creutzfeldt Ctr Cognit & Behav Neurosci, D-48149 Munster, Germany
[8] Univ Klinikum Knappschaftskrankenhaus Bochum, Neurol Klin, Ruhr Epileptol, Schornau 23-25, D-44892 Bochum, Germany
关键词
source analysis; source reconstruction; source localization; inverse solution; head volume conductor modelling; HEAD TISSUE CONDUCTIVITY; SOURCE LOCALIZATION; PRESURGICAL EVALUATION; SCALP EEG; IMPLANTED SOURCES; INVERSE PROBLEM; HUMAN SKULL; IN-VIVO; EPILEPSY; MODEL;
D O I
10.1093/braincomms/fcad023
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To evaluate the spatial accuracy of electrical source imaging (ESI) for known sources, Unnwongse et al. systematically performed ESI of averaged stimulation potentials recorded on simultaneous stereo-EEG and 37-electrode scalp EEG using individual finite element method models to determine the localization error. Electrical source imaging is used in presurgical epilepsy evaluation and in cognitive neurosciences to localize neuronal sources of brain potentials recorded on EEG. This study evaluates the spatial accuracy of electrical source imaging for known sources, using electrical stimulation potentials recorded on simultaneous stereo-EEG and 37-electrode scalp EEG, and identifies factors determining the localization error. In 11 patients undergoing simultaneous stereo-EEG and 37-electrode scalp EEG recordings, sequential series of 99-110 biphasic pulses (2 ms pulse width) were applied by bipolar electrical stimulation on adjacent contacts of implanted stereo-EEG electrodes. The scalp EEG correlates of stimulation potentials were recorded with a sampling rate of 30 kHz. Electrical source imaging of averaged stimulation potentials was calculated utilizing a dipole source model of peak stimulation potentials based on individual four-compartment finite element method head models with various skull conductivities (range from 0.0413 to 0.001 S/m). Fitted dipoles with a goodness of fit of >= 80% were included in the analysis. The localization error was calculated using the Euclidean distance between the estimated dipoles and the centre point of adjacent stimulating contacts. A total of 3619 stimulation locations, respectively, dipole localizations, were included in the evaluation. Mean localization errors ranged from 10.3 to 26 mm, depending on source depth and selected skull conductivity. The mean localization error increased with an increase in source depth (r(3617) = [0.19], P = 0.000) and decreased with an increase in skull conductivity (r(3617) = [-0.26], P = 0.000). High skull conductivities (0.0413-0.0118 S/m) yielded significantly lower localization errors for all source depths. For superficial sources (<20 mm from the inner skull), all skull conductivities yielded insignificantly different localization errors. However, for deeper sources, in particular >40 mm, high skull conductivities of 0.0413 and 0.0206 S/m yielded significantly lower localization errors. In relation to stimulation locations, the majority of estimated dipoles moved outward-forward-downward to inward-forward-downward with a decrease in source depth and an increase in skull conductivity. Multivariate analysis revealed that an increase in source depth, number of skull holes and white matter volume, while a decrease in skull conductivity independently led to higher localization error. This evaluation of electrical source imaging accuracy using artificial patterns with a high signal-to-noise ratio supports its application in presurgical epilepsy evaluation and cognitive neurosciences. In our artificial potential model, optimizing the selected skull conductivity minimized the localization error. Future studies should examine if this accounts for true neural signals.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Validating EEG source imaging using intracranial electrical stimulation
    Unnwongse, K.
    Rampp, S.
    Wehner, T.
    Kowoll, A.
    Parpaley, Y.
    von Lehe, M.
    Lanfer, B.
    Rusiniak, M.
    Wolters, C.
    Wellmer, J.
    [J]. EPILEPSIA, 2022, 63 : 101 - 102
  • [2] Validating MEG source imaging of resting state oscillatory patterns with an intracranial EEG atlas
    Afnan, Jawata
    von Ellenrieder, Nicolas
    Lina, Jean-Marc
    Pellegrino, Giovanni
    Arcara, Giorgio
    Cai, Zhengchen
    Hedrich, Tanguy
    Abdallah, Chifaou
    Khajehpour, Hassan
    Frauscher, Birgit
    Gotman, Jean
    Grova, Christophe
    [J]. NEUROIMAGE, 2023, 274
  • [3] Electrical Source Imaging of Somatosensory Evoked Potentials from Intracranial EEG Signals
    Adam Kalina
    Petr Jezdik
    Petr Fabera
    Petr Marusic
    Jiri Hammer
    [J]. Brain Topography, 2023, 36 : 835 - 853
  • [4] Electrical Source Imaging of Somatosensory Evoked Potentials from Intracranial EEG Signals
    Kalina, Adam
    Jezdik, Petr
    Fabera, Petr
    Marusic, Petr
    Hammer, Jiri
    [J]. BRAIN TOPOGRAPHY, 2023, 36 (06) : 835 - 853
  • [5] Automated electrical source imaging with scalp EEG to define the insular irritative zone: Comparison with simultaneous intracranial EEG
    Iachim, Evelina
    Vespa, Simone
    Baroumand, Amir G.
    Danthine, Venethia
    Vrielynck, Pascal
    de Tourtchaninoff, Marianne
    Fierain, Alexane
    Vaz, Jose Geraldo Ribeiro
    Raftopoulos, Christian
    Santos, Susana Ferrao
    van Mierlo, Pieter
    El Tahry, Riem
    [J]. CLINICAL NEUROPHYSIOLOGY, 2021, 132 (12) : 2965 - 2978
  • [6] Electrocortical Source Imaging of Intracranial EEG Data in Epilepsy
    Acar, Zeynep Akalin
    Palmer, Jason
    Worrell, Gregory
    Makeig, Scott
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 3909 - 3912
  • [7] EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy
    Cox, Benjamin C.
    Danoun, Omar A.
    Lundstrom, Brian Nils
    Lagerlund, Terrence D.
    Wong-Kisiel, Lily C.
    Brinkmann, Benjamin H.
    [J]. BRAIN COMMUNICATIONS, 2021, 3 (04)
  • [8] COMPARATIVE SPIKE MAPPING USING INTRACRANIAL SINGLE-PULSE ELECTRICAL CORTICAL STIMULATION AND INTRACRANIAL EEG-FMRI
    Grade, M.
    Carmichael, D. W.
    Chaudhary, U. J.
    Lemieux, L.
    Diehl, B.
    [J]. EPILEPSIA, 2014, 55 : 14 - 14
  • [9] Influence of magnetic source imaging for planning intracranial EEG in epilepsy
    Sutherling, W. W.
    Mamelak, A. N.
    Thyerlei, D.
    Maleeva, T.
    Minazad, Y.
    Philpott, L.
    Lopez, N.
    [J]. NEUROLOGY, 2008, 71 (13) : 990 - 996
  • [10] COMPARISON OF FOCUS LOCALIZATION WITH EEG SOURCE IMAGING TO OTHER NON INVASIVE IMAGING METHODS AND INTRACRANIAL EEG
    Brodbeck, V.
    Spinelli, L.
    Delavelle, J.
    Wissmeyer, M.
    Michel, C. M.
    Seeck, M.
    [J]. EPILEPSIA, 2009, 50 : 8 - 8