Multi- probe Linear Matrix Inversion Method in Sub-array Internal Element Calibration

被引:0
|
作者
Zhang, Yusheng [1 ]
Wang, Zhengpeng [1 ]
Miao, Jungang [1 ]
机构
[1] Beihang Univ, Sch Elect & Informat Engn, Beijing, Peoples R China
关键词
Antenna array calibration; multi-probe calibration; OTA measurement; linear matrix inversion; condition number; ARRAY; DIAGNOSIS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a sub-array internal element calibration method using linear matrix inversion method. Multiprobe is employed to detect the E-field distribution of the subarray under test in the near field. A transmission matrix between the sub-array and probes is built. The key point of this method is getting low condition number transmission matrix. Furthermore, optimization strategy based on genetic algorithm is introduced to obtain more stable matrices. Simulation results show only 4 probes are needed for a 4-element array testing. Finally, a 4-element sub-array composed of rectangular waveguide antennas operating at 3.5 GHz was measured to validate the effectiveness of the proposed method, and the results show a high accuracy - the error between the proposed method and the reference test is less than +/- 0.2dB, +/- 2 degrees.
引用
收藏
页数:5
相关论文
共 11 条
  • [1] Multi-Element Phased Array Calibration Method by Solving Linear Equations
    Long, Rui
    Ouyang, Jun
    Yang, Feng
    Han, Wangwang
    Zhou, Longjian
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2017, 65 (06) : 2931 - 2939
  • [2] Internal Calibration Method of Linear Array CCD Using Nonparametric Model
    Wu Jun
    Xu Jun
    Li Yanling
    Li Zechuan
    Li Xin
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (04)
  • [3] Calibration method for the structure parameters of a single linear array CCD-based photoelectric detection system using a matrix inversion transformation
    Dong, Tao
    Yang, Jiuqi
    Chen, Ding
    Chen, Dachuan
    OPTIK, 2018, 171 : 446 - 452
  • [4] Study on the calibration method for orthogonal 3D scanning probe system based on the linear calibration matrix
    Wan, Peng
    Guo, Junjie
    Li, Beizhan
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY II, PTS 1 AND 2, 2012, 503-504 : 1401 - 1407
  • [5] Method for Determining Elements of Internal Orientation Calibration in Multi-Matrix Optoelectronic Devices
    Starasotnikau, M. A.
    Padskrebkin, I. V.
    Feodortsau, R. V.
    SCIENCE & TECHNIQUE, 2020, 19 (05): : 428 - 436
  • [6] Calibration Method for Multi Static Linear Array Radar with One Dimensional Array Antenna Arranged in Staggered Manner
    Mori, Yasunari
    Yumii, Takayoshi
    Asano, Yumi
    Doi, Kyouji
    Koyama, Christian N.
    Iitsuka, Yasushi
    Takahashi, Kazunori
    Sato, Motoyuki
    IEICE TRANSACTIONS ON ELECTRONICS, 2018, E101C (01): : 26 - 34
  • [7] A 71-to-86-GHz 16-Element by 16-Beam Multi-User Beamforming Integrated Receiver Sub-Array for Massive MIMO
    Naviasky, Emily
    Iotti, Lorenzo
    LaCaille, Greg
    Nikolic, Borivoje
    Alon, Elad
    Niknejad, Ali M.
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2021, 56 (12) : 3811 - 3826
  • [8] Study on a geometric calibration method for three-linear-array CCD camera with sub-pixel accuracy
    Liu, Jin-Guo
    Li, Jie
    Hao, Zhi-Hang
    Guangdian Gongcheng/Opto-Electronic Engineering, 2004, 31 (01): : 36 - 39
  • [9] A Novel Calibration Method for Phased-Array Radar based on Element-wise Time Offsetting and Multi-Element Phase Toggle
    Magalhaes, Giorgio
    Leon, Julio
    de Menezes, Marcio
    2019 IEEE RADAR CONFERENCE (RADARCONF), 2019,
  • [10] Isotope Inversion Experiment evaluating the suitability of calibration in surrogate matrix for quantification via LC-MS/MS-Exemplary application for a steroid multi-method
    Suhr, Anna Catharina
    Vogeser, Michael
    Grimm, Stefanie H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 124 : 309 - 318