Simultaneous Multi-Angular Relaxometry of Tissue With MRI (SMART MRI): Theoretical Background and Proof of Concept

被引:5
|
作者
Sukstanskii, Alexander L. [1 ]
Wen, Jie [1 ]
Cross, Anne H. [1 ]
Yablonskiy, Dmitriy A. [1 ]
机构
[1] Washington Univ, Dept Radiol, St Louis, MO USA
关键词
MRI; T1; relaxation; T2*relaxation; magnetization transfer; variable flip angles; gradient echo; steady state; PULSED MAGNETIZATION-TRANSFER; GRADIENT-ECHO MRI; BLOOD OXYGENATION; WHITE-MATTER; STEADY-STATE; BIOPHYSICAL MECHANISMS; TRANSFER CONTRAST; BAYESIAN VIEW; BRAIN IMAGES; RELAXATION;
D O I
10.1002/mrm.26176
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurate measurement of tissue-specific relaxation parameters is an ultimate goal of quantitative MRI. The objective of this study is to introduce a new technique, simultaneous multiangular relaxometry of tissue with MRI (SMART MRI), which provides naturally coregistered quantitative spin density, longitudinal and transverse relaxation rate constant maps along with parameters characterizing magnetization transfer (MT) effects. Theory and Methods: SMART MRI is based on a gradientrecalled echo MRI sequence with multiple flip angles and multiple gradient echoes and a derived theoretical expression for the MR signal generated in this experimental conditions. The theory, based on Bloch-McConnell equations, takes into consideration cross-relaxation between two water pools: " free" and " bound" to macromolecules. It describes the role of cross-relaxation effects in formation of longitudinal and transverse relaxation of "free" water signal, thus providing background for measurements of these effects without using MT pulses. Bayesian analysis is used to optimize SMART MRI sequence parameters. Results: Data obtained on three participants demonstrate feasibility of the proposed approach. Conclusion: SMART MRI provides quantitative measurements of longitudinal and transverse relaxation rate constants of "free" water signal affected by cross-relaxation effects. It also provides information on some essential MT parameters without requiring off-resonance MT pulses. (C) 2016 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1296 / 1306
页数:11
相关论文
共 11 条
  • [1] Quantitative Evaluation of Brain Tissue Damage in Multiple Sclerosis with SMART (Simultaneous MultiAngular Relaxometry of Tissue) MRI
    Xiang, Biao
    Wen, Jie
    Cross, Anne H.
    Yablonskiy, Dmitriy
    MULTIPLE SCLEROSIS JOURNAL, 2019, 25 : 105 - 105
  • [2] Evaluating brain damage in multiple sclerosis with simultaneous multi-angular-relaxometry of tissue
    Xiang, Biao
    Wen, Jie
    Schmidt, Robert E.
    Sukstanskii, Alexander L.
    Mamah, Daniel
    Yablonskiy, Dmitriy A.
    Cross, Anne H.
    ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2022, 9 (10): : 1514 - 1527
  • [3] Non-equal Channel Multi-Angular Extrusion (NECMAE): A Design for Severe Plastic Deformation—Proof of Concept
    Mohamed S. El-Asfoury
    Mohamed N. A. Nasr
    Ahmed Abdel-Moneim
    Transactions of the Indian Institute of Metals, 2019, 72 : 2827 - 2838
  • [4] Non-equal Channel Multi-Angular Extrusion (NECMAE): A Design for Severe Plastic Deformation-Proof of Concept
    El-Asfoury, Mohamed S.
    Nasr, Mohamed N. A.
    Abdel-Moneim, Ahmed
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2019, 72 (10) : 2827 - 2838
  • [5] Reduced acquisition time PET pharmacokinetic modelling using simultaneous ASL-MRI: proof of concept
    Scott, Catherine J.
    Jiao, Jieqing
    Melbourne, Andrew
    Burgos, Ninon
    Cash, David M.
    De Vita, Enrico
    Markiewicz, Pawel J.
    O'Connor, Antoinette
    Thomas, David L.
    Weston, Philip S. J.
    Schott, Jonathan M.
    Hutton, Brian F.
    Ourselin, Sebastien
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 (12): : 2419 - 2432
  • [6] Virtual slice concept for improved simultaneous multi-slice MRI employing an extended leakage constraint
    Park, Suhyung
    Chen, Liyong
    Beckett, Alexander
    Feinberg, David A.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 377 - 386
  • [7] MULTI-COMPARTMENT DIFFUSION MRI, T2 RELAXOMETRY AND MYELIN WATER IMAGING AS NEUROIMAGING DESCRIPTORS FOR ANOMALOUS TISSUE DETECTION
    Fischi-Gomez, Elda
    Rafael-Patino, Johnatan
    Pizzolato, Marco
    Piredda, Gian Franco
    Hilbert, Tom
    Kober, Tobias
    Canales-Rodriguez, Erick J.
    Thiran, Jean-Philippe
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 307 - 311
  • [8] Effects of biological tissue structural anisotropy and anisotropy of magnetic susceptibility on the gradient echo MRI signal phase: theoretical background
    Yablonskiy, Dmitriy A.
    Sukstanskii, Alexander L.
    NMR IN BIOMEDICINE, 2017, 30 (04)
  • [9] Multi-parametric [18F]PI-2620 tau PET/MRI in Alzheimer's disease variants: A proof-of-concept study
    Melasch, J.
    Rullmann, M.
    Scherlach, C.
    Saur, D.
    Schroeter, M. L.
    Tiepolt, S.
    Stephens, A.
    Koglin, N.
    Hesse, S.
    Strauss, M.
    Brendel, M.
    Aghakhanyan, G.
    Schildan, A.
    Mishchenko, O.
    Patt, M.
    Classen, J.
    Hoffmann, K.
    Sabri, O.
    Barthel, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S173 - S173
  • [10] Multi-parametric [18F]PI-2620 tau PET/MRI in Alzheimer's disease variants: A proof-of-concept study
    Melasch, Juliana
    Rullmann, Michael
    Saur, Dorothee
    Schroeter, Matthias
    Tiepolt, Solveig
    Koglin, Norman
    Stephens, Andrew
    Hesse, Swen
    Strauss, Maria
    Brendel, Matthias
    Scherlach, Cordula
    Hoffmann, Karl-Titus
    Schildan, Andreas
    Mishchenko, Olena
    Patt, Marianne
    Classen, Joseph
    Sabri, Osama
    Barthel, Henryk
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62