Angiotensin Receptor Blockers in cyclodextrin nanoparticle eye drops: Ocular pharmacokinetics and pharmacologic effect on intraocular pressure

被引:15
|
作者
Lorenzo-Soler, Laura [1 ]
Olafsdottir, Olof Birna [1 ,2 ,3 ]
Garhoefer, Gerhard [4 ]
Jansook, Phatsawee [5 ]
Kristinsdottir, Iris Myrdal [3 ]
Tan, Aimin [6 ]
Loftsson, Thorsteinn [7 ]
Stefansson, Einar [1 ,2 ,3 ]
机构
[1] Univ Iceland, Fac Med, Vatnsmyrarvegur 16, IS-101 Reykjavik, Iceland
[2] Landspitali Univ Hosp, Dept Ophthalmol, Reykjavik, Iceland
[3] Oculis Ehf, Reykjavik, Iceland
[4] Med Univ Vienna, Dept Clin Pharmacol, Vienna, Austria
[5] Chulalongkorn Univ, Fac Pharmaceut Sci, Bangkok, Thailand
[6] Nucro Tech, Toronto, ON, Canada
[7] Univ Iceland, Fac Pharm, Reykjavik, Iceland
基金
欧盟地平线“2020”;
关键词
angiotensin receptor blockers; glaucoma; intraocular pressure; pharmacokinetics;
D O I
10.1111/aos.14639
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Orally administered angiotensin II receptor blockers (ARBs) decrease intraocular pressure (IOP). Topical administration may reduce systemic side effects and result in a useful glaucoma drug. The aim of this study is to test the ocular delivery and pharmacologic effect of nanoparticle eye drops containing ARBs (e.g. irbesartan and candesartan). Methods 1.5% irbesartan and 0.15% candesartan eye drops were applied to rabbits. The pharmacokinetics in cornea and aqueous humour after single eye drop application were studied in 49 rabbits. The effect of the eye drops on IOP was studied in 10 rabbits using an iCare ((R) TonoVet Plus, iCare, Finland) tonometer and compared with 0.5% timolol eye drops. Results Candesartan lowered IOP from 24.6 +/- 5.1 mmHg at baseline to 19.0 +/- 2.9 mmHg (mean +/- SD, p = 0.030, n = 10) 4 hr after application. Irbesartan lowered IOP from 24.2 +/- 1.7 mmHg to 20.2 +/- 0.9 mmHg (p = 0.14, n = 10). Timolol decreased the IOP from 24.9 +/- 4.2 mmHg to 20.4 +/- 4.8 mmHg (mean +/- SD, p = 0.036, n = 10). The pharmacokinetics data show that both formulations deliver effective amounts of drug into the intraocular tissues, with irbesartan and candesartan reaching concentrations of 121 +/- 69 and 30.43 +/- 13.93 ng/g (mean +/- SD), respectively, in the aqueous humour 3 hr after a single-dose administration. Conclusions Topical application of irbesartan and candesartan eye drops delivers effective drug concentrations to the anterior segment of the eye in rabbits, achieving drug concentrations 100 times above the IC50 for angiotensin II receptor and showing an IOP-lowering effect. Angiotensin receptor blocker (ARB) eye drops have potential as a new class of glaucoma drugs.
引用
收藏
页码:376 / 382
页数:7
相关论文
共 47 条
  • [1] Angiotensin Receptor Blockers in Cyclodextrin Nanoparticle Eye Drops: Ocular Pharmacokinetics and Pharmacologic Effect on Intraocular Pressure
    Lorenzo-Soler, Laura
    Garhoefer, Gerhard
    Olafsdottir, Olof Birna
    Kristinsdottir, Iris Myrdal
    Jansook, Phatsawee
    Loftsson, Thorsteinn
    Stefansson, Einar
    ACTA PHYSIOLOGICA, 2019, 227 : 61 - 62
  • [2] Pharmacokinetics of angiotensin-receptor blocker in cyclodextrin nanoparticle eye drops in rabbits
    Kallab, Martin
    Schutzenberger, Kornelia
    Hommer, Nikolaus
    Schafer, Bhavapriya Jasmin
    Tan, Aimin
    Jansook, Phatsawee
    Stefansson, Einar
    Garhofer, Gerhard
    ACTA OPHTHALMOLOGICA, 2019, 97
  • [3] γ-Cyclodextrin Nanoparticle Eye Drops with Dorzolamide: Effect on Intraocular Pressure in Man
    Gudmundsdottir, Birna S.
    Petursdottir, Dyrleif
    Asgrimsdottir, Gudrun M.
    Gottfredsdottir, Maria S.
    Hardarson, Sveinn H.
    Johannesson, Gauti
    Kurkov, Sergey V.
    Jansook, Phatsawee
    Loftsson, Thorsteinn
    Stefansson, Einar
    JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2014, 30 (01) : 35 - 41
  • [4] Angiotensin II receptor blockers in nanoparticle eye drops lower IOP in rabbits
    Lorenzo-Soler, Laura
    Olafsdottir, Olof Birna
    Kristinsdottir, Iris Myrdal
    Jansook, Phatsawee
    Loftsson, Thorsteinn
    Stefansson, Einar
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [5] Methazolamide 1% in cyclodextrin aqueous eye drops lowers intraocular pressure in ocular hypertensive humans
    Stefansson, E
    Guömundsdóttir, E
    Sigurjónsdóttir, J
    Bjarnadóttir, G
    Misson, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S664 - S664
  • [6] CLOBETASONE BUTYRATE EYE DROPS - EFFECT ON OCULAR INFLAMMATION AND INTRAOCULAR-PRESSURE
    WILLIAMSON, J
    EILON, LA
    WALKER, SR
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1981, 101 (APR): : 27 - 29
  • [7] Pharmacokinetics and Local Tolerability of Cyclodextrin-based Angiotensin-Receptor Antagonist eye drops in rabbits
    Garhofer, Gerhard
    Kallab, Martin
    Schutzenberger, Kornelia
    Schaefer, Bhavapriya
    Tan, Aimin
    Jansook, Phatsawee
    Zeitlinger, Markus
    Lorenzo-Soler, Laura
    Stefansson, Einar
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [8] EFFECT OF OXYBUPROCAINE (NOVESINE) EYE-DROPS ON INTRAOCULAR-PRESSURE
    LEYS, M
    VANRIJ, G
    DEHEER, LJ
    OPHTHALMOLOGICA, 1986, 192 (02) : 109 - 110
  • [9] Effect of Nepafenac Eye Drops on Intraocular Pressure: A Randomized Prospective Study
    Dave, Paaraj
    Shah, Kuntal
    Ramchandani, Bharat
    Jain, Rupa
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (03) : 735 - 738
  • [10] The Effect of Intraocular Pressure-lowering Eye Drops on Myopic Retinoschisis Patients
    Lee, Jung Hwa
    Jang, Kyu Hwan
    Lee, Suchan
    Kong, Mingui
    Sohn, Joon Hong
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (04): : 341 - 346