A data acquisition and processing system for 3-D position sensitive CZT gamma-ray spectrometers

被引:16
|
作者
Li, W [1 ]
He, Z [1 ]
Knoll, GF [1 ]
Wehe, DK [1 ]
Berry, JE [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
D O I
10.1109/23.819268
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A PC-based data acquisition and processing system has been developed for two 3-D position-sensitive CZT gamma ray detectors. For each 3-D CZT detector, an integrated readout chip (VA1) is used to read out the signals from the 11x11 anode pixels. Two independent preamplifiers are used to read out the signals from the cathode and the grid electrodes that are used as trigger signals for low and high energy incident gamma rays, respectively. A PC-based DAQ board samples the amplitudes of the signals from the anode pixels and the cathode. The software collects and processes the energy spectra from the sampling data. The typical equivalent electronic noise of this system is measured to be 6 keV and 7 keV for the two 3-D CZT detectors, and the dynamic range of the system is up to 1 MeV. Spectra from 60, 122 and 662 keV gamma rays have been successfully measured using the two 3-D CZT detectors.
引用
收藏
页码:1989 / 1994
页数:6
相关论文
共 50 条
  • [1] Spatial variation of energy resolution in 3-D position sensitive CZT gamma-ray spectrometers
    Univ of Michigan, Ann Arbor, United States
    IEEE Nucl Sci Symp Med Imaging Conf, (628-633):
  • [2] Spatial variation of energy resolution in 3-D position sensitive CZT gamma-ray spectrometers
    Li, W
    He, Z
    Knoll, GF
    Wehe, DK
    Stahle, CM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 187 - 192
  • [3] Analysis of detector response using 3-D position sensitive CZT gamma-ray spectrometers
    Zhang, F
    He, Z
    Xu, D
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3493 - 3497
  • [4] 3-D position sensitive CdZnTe gamma-ray spectrometers
    He, Z
    Li, W
    Knoll, GF
    Wehe, DK
    Berry, J
    Stahle, CM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 173 - 178
  • [5] Analysis of detector response using 3-D position-sensitive CZT gamma-ray spectrometers
    Zhang, F
    He, Z
    Xu, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 3098 - 3104
  • [6] Effects of charge sharing in 3-D position sensitive CdZnTe gamma-ray spectrometers
    He, Z
    Li, W
    Knoll, GF
    Wehe, DK
    Du, YF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 439 (2-3): : 619 - 624
  • [7] Impact of temperature variation on the energy resolution of 3D position sensitive CZT gamma-ray spectrometers
    Li, Wen
    Du, Yanfeng
    Yanoff, Brian D.
    Gordon, Jeffrey S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1809 - 1815
  • [8] Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers
    He, Z
    Li, W
    Knoll, GF
    Wehe, DK
    Stahle, CM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 441 (03): : 459 - 467
  • [9] First acquisition of data from a prototype 3-D Position Sensitive CZT PET system
    Abbaszadeh, Shiva
    Gu, Yi
    Sikora, Uzair
    Levin, Craig S.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [10] A modeling method to calibrate the interaction depth in 3-D position sensitive CdZnTe gamma-ray spectrometers
    Li, W
    He, Z
    Knoll, GF
    Wehe, DK
    Du, YF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 890 - 894