Charge sharing in double-sided 3D Medipix2 detectors

被引:8
|
作者
Pennicard, D. [1 ]
Fleta, C. [1 ]
Bates, R. [1 ]
O'Shea, V. [1 ]
Parkes, C. [1 ]
Pellegrini, G. [3 ]
Lozano, M. [3 ]
Marchal, J. [2 ]
Tartoni, N. [2 ]
机构
[1] Univ Glasgow, Dept Phys & Astron, Glasgow G12 8QQ, Lanark, Scotland
[2] Diamond Light Source Ltd, Oxford OX11 0DE, England
[3] CSIC, CNM IMB, Barcelona 08193, Spain
关键词
3D detectors; Charge sharing; X-ray detectors; Synchrotron; Medipix; PIXEL; PARTICLES; DEVICE;
D O I
10.1016/j.nima.2009.01.095
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
3D detectors are photodiode detectors with n- and p-type electrode columns passing through a silicon substrate. This structure gives a much smaller spacing between the electrodes than in a standard photodiode, greatly reducing the detector's operating voltage and collection time. The device structure also reduces charge sharing between adjacent pixels. This improves the image quality, making these detectors potentially useful for applications such as X-ray diffraction experiments in synchrotrons. A set of silicon detectors with a simplified "double-sided" 3D structure have been fabricated. After being bump-bonded to Medipix2 single-photon-counting readout chips, they have been tested using X-rays and alpha particles. The test results show that the 3D detectors have substantially lower charge sharing than a planar detector of the same thickness. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:412 / 415
页数:4
相关论文
共 50 条
  • [1] Simulation Results from Double-Sided 3D Detectors
    Pennicard, D.
    Pellegrini, G.
    Lozano, M.
    Bates, R.
    Parkes, C.
    Wright, V.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1614 - 1618
  • [2] Slim edges in double-sided silicon 3D detectors
    Povoli, M.
    Bagolini, A.
    Boscardin, M.
    Dalla Betta, G. -F.
    Giacomini, G.
    Vianello, E.
    Zorzi, N.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [3] Synchrotron tests of 3D Medipix2 and TimePix X-Ray Detectors
    Mac Raighne, Aaron
    Akiba, K. C.
    Alianelli, L.
    Artuso, M.
    Bates, R.
    Bayer, F.
    Buytaert, J.
    Collins, P.
    Crossley, M.
    Eklund, L.
    Fleta, C.
    Gallas, A.
    Gandelman, M.
    Gersabeck, M.
    Gimenez, E. N.
    Gligorov, V.
    Huse, T.
    John, M.
    Llin, L. F.
    Lozano, M.
    Maneuski, D.
    Marchal, J.
    Michel, T.
    Nicol, M.
    Pellegrini, G.
    Perira, D. E.
    Plackett, R.
    O'Shea, V.
    Parkes, C.
    Rodrigues, E.
    Sawhney, K. J. S.
    Tartoni, N.
    Vazquez, P.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2145 - +
  • [4] Investigation of charge carrier transport and charge sharing in X-ray semiconductor pixel detectors such as Medipix2
    Korn, Alexander
    Firsching, Markus
    Anton, Gisela
    Hoheisel, Martin
    Michel, Thilo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 239 - 242
  • [5] Study of the Charge Sharing Effect with Protons Interacting with a Medipix2 Detector
    Bouchami, J.
    Gutierrez, A.
    Houdayer, A.
    Jakubek, J.
    Lebel, C.
    Leroy, C.
    Macana, J.
    Martin, J. -P.
    Platkevic, M.
    Pospisil, S.
    Teyssier, C.
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2009, 1204 : 175 - +
  • [6] Charge collection studies of heavily irradiated 3D Double-Sided sensors
    Bates, Richard L.
    Parkes, C.
    Pennicard, D.
    Rakotomiaramanana, B.
    Fleta, C.
    Pellegrini, G.
    Lozano, M.
    Parzefall, U.
    Blot, X.
    Haerkoenen, J.
    Tuovinen, E.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 148 - +
  • [7] Layout and Process Improvements to Double-Sided Silicon 3D Detectors Fabricated at FBK
    Povoli, Marco
    Betta, Gian-Franco Dalla
    Bagolini, Alvise
    Boscardin, Maurizio
    Giacomini, Gabriele
    Mattedi, Francesca
    Zorzi, Nicola
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1334 - 1338
  • [8] X-ray detection with 3D Medipix2 devices
    Fleta, C.
    Pennicard, D.
    Bates, R.
    O'Shea, V.
    Parkes, C.
    Lozano, M.
    Pellegrini, G.
    Marchal, J.
    Tartoni, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 89 - 91
  • [9] CHARGE SHARING AND RESOLUTION STUDIES OF DOUBLE-SIDED SILICON MICROSTRIPE DETECTORS WITH BORON SPRAY IMPLANTS
    KALBFLEISCH, GR
    SMITH, EH
    KAPLAN, DH
    GUTIERREZ, P
    KUEHLER, J
    SKUBIC, P
    WOOD, M
    MCMAHON, T
    SNOW, JM
    BULLOUGH, M
    LUCAS, AD
    WILBURN, CD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 355 (2-3): : 366 - 385
  • [10] Synchrotron Tests of a 3D Medipix2 X-Ray Detector
    Pennicard, David
    Marchal, Julien
    Fleta, Celeste
    Pellegrini, Giulio
    Lozano, Manuel
    Parkes, Chris
    Tartoni, Nicola
    Barnett, Damien
    Dolbnya, Igor
    Sawhney, Kawal
    Bates, Richard
    O'Shea, Val
    Wright, Victoria
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 387 - 394