Soft-tissue phase-contrast tomography with an x-ray tube source

被引:117
|
作者
Bech, Martin [1 ]
Jensen, Torben H. [1 ]
Feidenhans'l, Robert [1 ]
Bunk, Oliver [2 ]
David, Christian [2 ]
Pfeiffer, Franz [2 ,3 ]
机构
[1] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[2] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[3] Ecole Polytech Fed Lausanne, CH-1015 Lausanne, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 09期
关键词
GRATING INTERFEROMETER; TALBOT INTERFEROMETRY; REFRACTION CONTRAST; MICROTOMOGRAPHY;
D O I
10.1088/0031-9155/54/9/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We report the first experimental soft-tissue phase-contrast tomography results using a conventional x-ray tube source, with a millimeter-sized focal spot. The setup is based on a Talbot-Lau grating interferometer operated at a mean energy of 28 keV. We present three-dimensional ex vivo images of a chicken heart sample, fixated in formalin. The results clearly demonstrate the advantageous contrast attainable through phase-contrast imaging over conventional attenuation-based approaches.
引用
收藏
页码:2747 / 2753
页数:7
相关论文
共 50 条
  • [1] X-ray phase-contrast imaging study of soft-tissue and bone samples
    Gao, DC
    Pogany, A
    Stevenson, AW
    Gureyev, T
    Wilkins, SW
    [J]. MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 346 - 355
  • [2] Polychromatic X-ray in-line phase-contrast tomography for soft tissue
    Guo, Xue-Jun
    Liu, Xiao-Lin
    Gu, Mu
    Ni, Chen
    Huang, Shi-Ming
    Liu, Bo
    [J]. EPL, 2012, 98 (01)
  • [3] X-ray phase-contrast tomography
    Bushuev, VA
    Ingal, VN
    Beliaevskaya, EA
    Sergeev, AA
    [J]. METALLOFIZIKA I NOVEISHIE TEKHNOLOGII, 2002, 24 (04): : 559 - 569
  • [4] Quantitative phase-contrast tomography of a liquid phantom using a conventional x-ray tube source
    Herzen, Julia
    Donath, Tilman
    Pfeiffer, Franz
    Bunk, Oliver
    Padeste, Celestino
    Beckmann, Felix
    Schreyer, Andreas
    David, Christian
    [J]. OPTICS EXPRESS, 2009, 17 (12): : 10010 - 10018
  • [5] Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source
    Donath, Tilman
    Pfeiffer, Franz
    Bunk, Oliver
    Groot, Waldemar
    Bednarzik, Martin
    Gruenzweig, Christian
    Hempel, Eckhard
    Popescu, Stefan
    Hoheisel, Martin
    David, Christian
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (05):
  • [6] Toward Clinical X-ray Phase-Contrast CT Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen
    Donath, Tilman
    Pfeiffer, Franz
    Bunk, Oliver
    Gruenzweig, Christian
    Hempel, Eckhard
    Popescu, Stefan
    Vock, Peter
    David, Christian
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (07) : 445 - 452
  • [7] Phase-contrast X-ray computed tomography for observing biological soft tissues
    Momose, A
    Takeda, T
    Itai, Y
    Hirano, K
    [J]. NATURE MEDICINE, 1996, 2 (04) : 473 - 475
  • [8] Compact phase-contrast soft X-ray microscopy
    von Hofsten, O.
    Bertilson, M.
    Lindblom, M.
    Holmberg, A.
    Hertz, H. M.
    Vogt, U.
    [J]. 9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [9] Statistical Properties of X-Ray Phase-Contrast Tomography
    Chou, Cheng-Ying
    Anastasio, Mark A.
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 6648 - +
  • [10] Interlaced phase stepping in phase-contrast x-ray tomography
    Zanette, I.
    Bech, M.
    Pfeiffer, F.
    Weitkamp, T.
    [J]. APPLIED PHYSICS LETTERS, 2011, 98 (09)