Segmental motion adjacent to an instrumented lumbar fusion - The effect of extension of fusion to the sacrum

被引:35
|
作者
Untch, C [1 ]
Liu, Q [1 ]
Hart, R [1 ]
机构
[1] OHSU, Dept Orthopaed & Rehabil, Portland, OR 97201 USA
关键词
adjacent segment degeneration; fusion; lumbosacral; lumbar; biomechanics;
D O I
10.1097/01.brs.0000143667.55696.bd
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. We present an in vitro biomechanical comparison of adjacent segment motion at the cranial segment (L3-L4) for an L4-L5 versus an L4-S1 fusion model using cadaveric lumbosacral spines. Objectives. The purpose is to determine the biomechanical effect on the unfused cranial segment of extending a short lumbar fusion to the sacrum versus stopping at L5. Summary of Background Data. Radiographic evidence of adjacent segment degeneration can occur as a late sequela in patients following lumbar and lumbosacral spinal fusions. It is believed that altered biomechanics adjacent to the fusion construct contribute to these degenerative changes. Little is known regarding changes in cranial adjacent segment mechanics resulting from inclusion of the sacrum compared to ending a fusion at L5. Methods. Seven human cadaveric lumbosacral spines were instrumented with pedicle screws at L4, L5, and S1. Rods were placed from L4-L5 and from L4-S1 to simulate the corresponding fusion models. A material testing system was used to apply load-controlled moments to the spines in flexion-extension, lateral bending, and axial rotation. Electromagnetic sensors were used to record 6 df motion across the L3-L4, L4-L5, and L5-S1 motion segments. Angular displacements were recorded and system stiffness was calculated for each spine and construct. A paired sample t test was used to determine significance of recorded differences. Results. Under flexion-extension loading, the angular displacement in the sagittal plane at L3-L4 for the L4-S1 model was 9.0 compared to 7.8 for the L4-L5 model (+15%; P = 0.002). Under lateral bending loading, L3-L4 motion in the coronal plane for the L4-S1 model was 12.8 and was 14.5 for the L4-L5 model (-12%; P = 0.002). In axial rotation testing, L3-L4 torsional motion for the L4-S1 model was equivalent to the L4-L5 model. Overall system stiffness increased for the L4-S1 model compared with the L4-L5 model. Conclusions. In this load-controlled model, extending fusion across L5-S1 did not consistently increase motion at L3-L4. While it may be difficult to translate this finding to a clinical setting, avoiding fusion to the sacrum in a lower lumbar fusion may not provide significant benefit from the standpoint of avoiding adjacent segment disease.
引用
收藏
页码:2376 / 2381
页数:6
相关论文
共 50 条
  • [1] The biomechanical effect of postoperative hypolordosis in instrumented lumbar fusion on instrumented and adjacent spinal segments
    Umehara, S
    Zindrick, MR
    Patwardhan, AG
    Havey, RM
    Vrbos, LA
    Knight, GW
    Miyano, S
    Kirincic, M
    Kaneda, K
    Lorenz, MA
    SPINE, 2000, 25 (13) : 1617 - 1624
  • [2] The fate of the adjacent motion segments after lumbar fusion
    Gillet, P
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2003, 16 (04): : 338 - 345
  • [3] Comparison of instrumented anterior interbody fusion with instrumented circumferential lumbar fusion
    S. S. Madan
    N. R. Boeree
    European Spine Journal, 2003, 12 : 567 - 575
  • [4] Comparison of instrumented anterior interbody fusion with instrumented circumferential lumbar fusion
    Madan, SS
    Boeree, NR
    EUROPEAN SPINE JOURNAL, 2003, 12 (06) : 567 - 575
  • [5] Lumbar Fusion in Achondroplasia Does Fusion to the Sacrum Affect Function?
    Farmer, Kevin W.
    Brinkley, Michael F.
    Skolasky, Richard L.
    Sponseller, Paul D.
    Ain, Michael C.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2009, 29 (05) : 476 - 480
  • [6] The clinical characteristics and risk factors for the adjacent segment degeneration in instrumented lumbar fusion
    Min, Jun-Hong
    Jang, Jee-Soo
    Jung, Byungjoo
    Lee, Ho Yeon
    Choi, Won-Chul
    Shim, Chan Shik
    Choi, Gun
    Lee, Sang-Ho
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (05): : 305 - 309
  • [7] Impact of lumbar instrumented circumferential fusion on the development of adjacent vertebral compression fracture
    Li, Y-C.
    Yang, S-C.
    Chen, H-S.
    Kao, Y-H.
    Tu, Y-K.
    BONE & JOINT JOURNAL, 2015, 97B (10): : 1411 - 1416
  • [8] Interlaminar Endoscopic Treatment of Adjacent Segment Disease After Posterior Instrumented Lumbar Fusion
    Liang, Min
    Shao, Xinyang
    Zhu, Renhan
    Li, Kun
    Shi, Liangchen
    Wang, Yansong
    JOURNAL OF PAIN RESEARCH, 2025, 18 : 1011 - 1019
  • [9] Clinical Experiences of Non-fusion Dynamic Stabilization Surgery for Adjacent Segmental Pathology after Lumbar Fusion
    Lee, Soo Eon
    Jahng, Tae-Ahn
    Kim, Hyun-Jib
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2016, 10
  • [10] Adjacent-segment disease in 511 cases of posterolateral instrumented lumbar arthrodesis: floating fusion versus distal construct including the sacrum Clinical article
    Bydon, Mohamad
    Xu, Risheng
    Santiago-Dieppa, David
    Macki, Mohamed
    Sciubba, Daniel M.
    Wolinsky, Jean-Paul
    Bydon, Ali
    Gokaslan, Ziya L.
    Witham, Timothy F.
    JOURNAL OF NEUROSURGERY-SPINE, 2014, 20 (04) : 380 - 386