Comparison of macroscopic resorption time for a self-locking device and suture material in ovarian pedicle ligation in dogs

被引:3
|
作者
da Mota Costa, Matheus Roberto [1 ]
de Abreu Oliveira, Andre Lacerda [1 ]
de Moura Vidal, Leonardo Waldstein [1 ]
Ramos, Renato Moran [1 ]
Campos, Ingrid de Oliveira [1 ]
Hansson, Kerstin [2 ]
Ley, Charles J. [2 ]
Olsson, Ulf [3 ]
Borg, Niklas Olov [4 ]
Hoglund, Odd Viking [2 ,4 ]
机构
[1] Univ Estadual Norte Fluminense, Dept Anim Clin & Surg, Alberto, Brazil
[2] Swedish Univ Agr Sci, Dept Clin Sci, Uppsala, Sweden
[3] Swedish Univ Agr Sci, Dept Energy & Technol, Appl Stat & Math, Uppsala, Sweden
[4] Resorbable Devices AB, Uppsala, Sweden
关键词
NYLON CABLE BAND; HYDROLYTIC DEGRADATION; IN-VITRO; OVARIOHYSTERECTOMY; COPOLYMER; 1ST;
D O I
10.1136/vr.104732
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A resorbable self-locking device (LigaTie) was developed to enable safe and easy surgical ligation of blood vessels. The aim of this study was to compare the long-term in vivo resorption of the device to a commercially available suture of equivalent material (Maxon) following ovarian pedicle ligation. After ovariohysterectomy follow-up ultrasound examinations were performed monthly on 21 dogs ligated with the device and 22 dogs ligated with the suture material until no hyperechoic remnants, acoustic shadowing or local tissue reactions were detected. In both groups, the ovarian pedicles gradually decreased in size. Ligation material was considered macroscopically resorbed when ultrasound showed no signs of the device or suture, ovarian pedicle or tissue reaction. Macroscopic resorption had occurred without signs of complications and was complete by four months for sutures and 5.5 months for the device. The results show that resorption time in vivo for the resorbable self-locking device is mildly longer than suture of the same material and that no complications of device resorption were detected, supporting that the resorbable self-locking device is safe for in vivo use.
引用
收藏
页数:6
相关论文
共 6 条
  • [1] Ligation of the mesovarium in dogs with a self-locking implant of a resorbable polyglycolic based co-polymer: A study of feasibility and comparison to suture ligation
    Da Mota Costa M.R.
    De Abreu Oliveira A.L.
    Ramos R.M.
    De Moura Vidal L.W.
    Borg N.
    Höglund O.V.
    BMC Research Notes, 9 (1)
  • [2] Ligation of the ovarian pedicles in dogs with a resorbable self-locking device - a long-term follow-up study
    Hoglund, Odd V.
    Hagman, Ragnvi
    Olsson, Kerstin
    Carlsson, Carolina
    Sodersten, Fredrik
    Lagerstedt, Anne-Sofie
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2013, 27 (08) : 961 - 966
  • [3] Thoracoscopic-assisted lung lobectomy in cat cadavers using a resorbable self-locking ligation device
    Nylund, Adam M.
    Hoglund, Odd V.
    Fransson, Boel A.
    VETERINARY SURGERY, 2019, 48 (04) : 563 - 569
  • [4] Evaluation of a resorbable self-locking ligation device for performing peripheral lung biopsies in a caprine cadaveric model
    Nylund, Adam M.
    Chen, Chi-Ya
    Hoglund, Odd V.
    Campbell, Bonnie G.
    Fransson, Boel A.
    VETERINARY SURGERY, 2019, 48 (05) : 845 - 849
  • [5] Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer - Feasibility and long-Term follow-up study
    Höglund O.V.
    Ingman J.
    Södersten F.
    Hansson K.
    Borg N.
    Lagerstedt A.-S.
    BMC Research Notes, 7 (1)
  • [6] Biomechanical comparison of a modified three-loop pulley technique and a three-level self-locking technique for repair of patellar tendon rupture in dogs
    Soula, Mariajesus
    Shmalberg, Justin W.
    Johnson, Matthew D.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2019, 80 (04) : 335 - 341