Analytical performances of a new enzymatic assay for hemoglobin A1c

被引:18
|
作者
Jaisson, Stephane [1 ]
Desmons, Aurore [1 ]
Renard, Benoit [1 ]
Chevelle, Benjamin [1 ]
Leroy, Nathalie [1 ]
Gillery, Philippe [1 ]
机构
[1] Univ Hosp Reims, Amer Mem Hosp, Lab Paediat Biol & Res, Reims, France
关键词
Diabetes; Enzymatic assay; Evaluation; HbA(1c); IFCC REFERENCE METHOD; BIOLOGICAL VARIATION; HBA(1C); ANALYZER; GOALS;
D O I
10.1016/j.cca.2014.04.008
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: HbA(1c) is considered the gold standard for the follow-up of diabetic patients and a new diagnostic tool for diabetes mellitus, which implies the availability of reliable assay methods. We have evaluated a new assay developed by Abbott Laboratories, based on the enzymatic quantification of HbA(1c), by a fructosyl dipeptide oxidase using Architect analyzers. Methods: Precision, linearity, correlation with a HPLC method, accuracy and potential impact interferences on HbA(1c) measurement have been evaluated. Results: Intra-day and between-day CVs were lower than 1.2% and linearity was excellent from 19 mmol/mol (3.9%) to 163 mmol/mol (17.1%). The results were well correlated with those obtained by the HPLC (Variant II device, kit NU - BioRad): HbA(1c) [Architect, mmol/mol] = 0.986 x HbA(1c) [Variant II, mmol/mol] + 0.713 (r = 0.998, n = 109). This method provided consistent results with IFCC titrated quality control samples. Classical interferences in HbA(1c), assays (i.e. labile HbA(1c), carbamylated hemoglobin, triglycerides or bilirubin) did not have an impact on HbA(1c) quantification by this method. Conclusion: This new enzymatic assay proved to be a robust and reliable method for HbA(1c), measurement suitable for routine practice in clinical chemistry laboratories. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 52
页数:5
相关论文
共 50 条
  • [1] A new automated enzymatic assay for hemoglobin A1c
    Taniguchi, Y
    Nishio, T
    Saito, K
    Yago, H
    Ushizawa, K
    CLINICAL CHEMISTRY, 2005, 51 : A246 - A246
  • [2] Evaluation of an Enzymatic Hemoglobin A1C Assay
    Majeed, Numan
    Kanani, Fatima
    Zubairi, Adnan Mustafa
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2024, 30 (02): : 184 - 190
  • [3] Analytical performance evaluation of the Mindray enzymatic assay for hemoglobin A1c measurement
    Li, Mingyang
    Wu, Xiongjun
    Xie, Weijie
    Zeng, Yu
    Wang, Hui
    Chen, Han
    Xu, Anping
    Liu, Helu
    Ji, Ling
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [4] Development and evaluation of liquid type reagent for enzymatic Hemoglobin A1c assay
    Ueda, S.
    Matsuoka, T.
    Kouzuma, T.
    Imamura, S.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A101 - A101
  • [5] Comparison of Hb A1c Quantification in the Presence of Hemoglobin Variants of an HPLC Assay with an Enzymatic Assay
    Nichols, James H.
    Berman, Marvin
    Carrillo, Alex
    Manning, Suzanne
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2023, 8 (06): : 1127 - 1132
  • [6] Evaluation of an immunoturbidimetric assay for hemoglobin A1c
    Akan, P
    EUROMEDLAB 2003: PROCEEDINGS OF THE 15TH IFCC-FESCC EUROPEAN CONGRESS OF CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, : 187 - 193
  • [7] Analytical performance of a new single channel enzymatic assay for hemoglobin A1c for use on automated chemistry instruments without interference from variant hemoglobins
    Liu, L.
    Hood, S.
    Bezverkov, R.
    Dou, C.
    Borses, D. M.
    Yuan, C.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A183 - A183
  • [8] Analytical Performance Evaluation of Newly Developed Glycated Reagents for Hemoglobin A1c Assay
    Tian, Ke
    Yan, Nan
    Wang, Hongying
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (03): : 535 - 540
  • [9] AN IMPROVED COLORIMETRIC ASSAY FOR MEASUREMENT OF HEMOGLOBIN A1C
    LUZIO, SD
    HALES, CN
    DIABETOLOGIA, 1981, 20 (06) : 671 - 671
  • [10] More on the accuracy of the Architect enzymatic assay for hemoglobin A1c and its traceability to the IFCC reference system
    Szoke, Dominika
    Carnevale, Assunta
    Pasqualetti, Sara
    Braga, Federica
    Paleari, Renata
    Panteghini, Mauro
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (03) : E71 - E73