Dosimetry of very high energy electrons (VHEE) for radiotherapy applications: using radiochromic film measurements and Monte Carlo simulations

被引:39
|
作者
Subiel, A. [1 ]
Moskvin, V. [2 ]
Welsh, G. H. [1 ]
Cipiccia, S. [1 ]
Reboredo, D. [1 ]
Evans, P. [3 ]
Partridge, M. [4 ]
DesRosiers, C. [5 ]
Anania, M. P. [6 ]
Cianchi, A. [7 ]
Mostacci, A. [6 ]
Chiadroni, E. [6 ]
Di Giovenale, D. [6 ]
Villa, F. [6 ]
Pompili, R. [6 ]
Ferrario, M. [6 ]
Belleveglia, M. [6 ]
Di Pirro, G. [6 ]
Gatti, G. [6 ]
Vaccarezza, C. [6 ]
Seitz, B. [8 ]
Isaac, R. C. [9 ]
Brunetti, E. [1 ]
Wiggins, S. M. [1 ]
Ersfeld, B. [1 ]
Islam, M. R. [1 ]
Mendonca, M. S. [5 ]
Sorensen, A. [10 ]
Boyd, M. [10 ]
Jaroszynski, D. A. [1 ]
机构
[1] Univ Strathclyde, Scottish Univ Phys Alliance, Dept Phys, Glasgow G4 0NG, Lanark, Scotland
[2] Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USA
[3] Univ Surrey, Fac Engn & Phys Sci, Guildford GU2 7XH, Surrey, England
[4] Univ Oxford, Dept Oncol, Oxford OX3 7DQ, England
[5] Indiana Univ Sch Med, Dept Radiat Oncol, Indianapolis, IN 46202 USA
[6] Ist Nazl Fis Nucl, Lab Nazl Frascati, Rome, Italy
[7] Ist Nazl Fis Nucl, Rome, Italy
[8] Univ Glasgow, Sch Phys & Astron, Glasgow G12 8QQ, Lanark, Scotland
[9] Mar Athanasius Coll, Kothamangalam 686666, Kerala, India
[10] Univ Strathclyde, Strathclyde Inst Pharm & Biomed Sci, Glasgow G1 1XQ, Lanark, Scotland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 19期
基金
英国工程与自然科学研究理事会;
关键词
very high energy electrons; film dosimetry; Monte Carlo; EBT2; EBT2; FILM; GAFCHROMIC FILMS; WIDE-RANGE; PROTON; BEAMS; DEPENDENCE; PHOTON; THERAPY; FLUKA;
D O I
10.1088/0031-9155/59/19/5811
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic (R) film. Calibration of the film has been carried out for beams of two different energy ranges: 20 MeV and 165 MeV from conventional radio frequency linear accelerators. In addition, EBT2 film has been used for dose measurements with 135 MeV electron beams produced by a laser-plasma wakefield accelerator. The dose response measurements and percentage depth dose profiles have been compared with calculations carried out using the general-purpose FLUKA Monte Carlo (MC) radiation transport code. The impact of induced radioactivity on film response for VHEEs has been evaluated using the MC simulations. A neutron yield of the order of 10(-5) neutrons cm(-2) per incident electron has been estimated and induced activity due to radionuclide production is found to have a negligible effect on total dose deposition and film response. Neutron and proton contribution to the equivalent doses are negligible for VHEE. The study demonstrates that EBT2 Gafchromic film is a reliable dosimeter that can be used for dosimetry of VHEE. The results indicate an energy-independent response of the dosimeter for 20 MeV and 165 MeV electron beams and has been found to be suitable for dosimetry of VHEE.
引用
收藏
页码:5811 / 5829
页数:19
相关论文
共 50 条
  • [1] Dosimetry of 100 n 250 MeV Very High Energy Electrons (VHEE) as a new treatment modality for radiotherapy
    Subiel, A.
    Moskvin, V.
    Cipiccia, S.
    Welsh, G. H.
    Sorensen, A.
    Evans, P.
    Partridge, M.
    DesRosiers, C.
    Boyd, M.
    Jaroszynski, D. A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S228 - S228
  • [2] Investigation of stereotactic radiotherapy dose using dosimetry film and Monte Carlo simulations
    Kairn, T.
    Crowe, S.
    Kenny, J.
    Trapp, J. V.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1985 - 1988
  • [3] Mini-GRID radiotherapy on the CLEAR very-high-energy electron beamline: collimator optimization, film dosimetry, and Monte Carlo simulations
    Clements, Nathan
    Esplen, Nolan
    Bateman, Joseph
    Robertson, Cameron
    Dosanjh, Manjit
    Korysko, Pierre
    Farabolini, Wilfrid
    Corsini, Roberto
    Bazalova-Carter, Magdalena
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (05):
  • [4] Small photon beam measurements using radiochromic film and Monte Carlo simulations in a water phantom
    Garcia-Garduno, Olivia A.
    Larraga-Gutierrez, Jose M.
    Rodriguez-Villafuerte, Mercedes
    Martinez-Davalos, Arnulfo
    Celis, Miguel A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 (02) : 250 - 253
  • [5] Dosimetry of Strontium eye applicator: Comparison of Monte Carlo calculations and radiochromic film measurements
    Laoues, M.
    Khelifi, R.
    Moussa, A. S.
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [6] The value of radiochromic film dosimetry around air cavities: experimental results and Monte Carlo simulations
    Paelinck, L
    Reynaert, N
    Thierens, H
    De Wagter, C
    De Neve, W
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S12 - S12
  • [7] The value of radiochromic film dosimetry around air cavities: experimental results and Monte Carlo simulations
    Paelinck, L
    Reynaert, N
    Thierens, H
    De Wagter, C
    De Neve, W
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (13): : 1895 - 1905
  • [8] Measurements and Monte Carlo calculations to determine the absolute detector response of radiochromic film for brachytherapy dosimetry
    Bohm, TD
    Pearson, DW
    Das, RK
    MEDICAL PHYSICS, 2001, 28 (02) : 142 - 146
  • [9] CERN-based experiments and Monte-Carlo studies on focused dose delivery with very high energy electron (VHEE) beams for radiotherapy applications
    Whitmore, L.
    Mackay, R. I.
    van Herk, M.
    Korysko, P.
    Farabolini, W.
    Malyzhenkov, A.
    Corsini, R.
    Jones, R. M.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [10] Perturbation of radiotherapy beams by radiographic film: measurements and Monte Carlo simulations
    Suchowerska, N
    Hoban, P
    Davison, A
    Metcalfe, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (07): : 1755 - 1765