The performance Test and Analysis of Heat Recovery Type Heat Pipe Indirect Evaporative Cooling Air-Conditioning Unit

被引:0
|
作者
Huang, Xiang [1 ]
Wu, Sheng [1 ]
Fan, Li-juan [1 ]
Wang, Chao [1 ]
Wu, Jun-mei [1 ]
机构
[1] Xian Polytech Univ, Sch Environm & Chem Engn, Xian 710048, Shaanxi, Peoples R China
关键词
heat recovery; heat pipe; indirect evaporative cooling; heat pipe exchanger;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Combining the heat recovery technology of heat pipe and evaporative cooling technology, this article researched a heat recovery heat pipe-type indirect evaporative cooling air-conditioning unit and tested this unit. Based on analyzing we got main perfoprmance factors and best operation parameters. The best ratio of volume of secondary air and primary air is 0.8, the best water delivery is 0.322 m3/h, the efficiency of heat pipe-type indirect evaporative cooler is 70.39 %. This research provided reliable reference for the research and development of air-conditioning unit.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] The performance Test and Analysis of Heat Recovery Type Heat Pipe Indirect Evaporative Cooling Air-Conditioning Unit
    Huang, Xiang
    Wu, Sheng
    Fan, Li-juan
    Wang, Chao
    Wu, Jun-mei
    [J]. 2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [2] Experimental performance and parametric analysis of heat pipe heat exchanger for air conditioning application integrated with evaporative cooling
    Jadhav, Tushar S.
    Lele, Mandar M.
    [J]. HEAT AND MASS TRANSFER, 2017, 53 (11) : 3287 - 3293
  • [3] Experimental performance and parametric analysis of heat pipe heat exchanger for air conditioning application integrated with evaporative cooling
    Tushar S. Jadhav
    Mandar M. Lele
    [J]. Heat and Mass Transfer, 2017, 53 : 3287 - 3293
  • [4] Heat transfer performance of flat heat pipe based on air-conditioning energy recovery
    Xiahou, Guowei
    Xie, Mingfu
    Kong, Fangming
    Yang, Caiyun
    [J]. Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2015, 46 (01): : 317 - 323
  • [5] An air-conditioning system performance enhancement by using heat pipe based heat recovery technology
    Ahmadzadehtalatapeh, M.
    [J]. SCIENTIA IRANICA, 2013, 20 (02) : 329 - 336
  • [6] Performance experiment for heat pipe indirect evaporative cooling system
    Huang, Xiang
    Wu, Junmei
    Wang, Xiaojie
    Zheng, Jiujun
    [J]. Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2006, 57 (SUPPL.): : 63 - 67
  • [7] Performance analysis of heat recovery in Heat Pipe Heat Exchanger on room air conditioning systems
    Amir, Fazri
    Muhammad, Hafiz
    Abdullah, Nasruddin A.
    Rizal, Samsul
    Thaib, Razali
    Umar, Hamdani
    [J]. AIMS ENERGY, 2023, 11 (04) : 612 - 627
  • [8] Simulation study on the operating characteristics of the heat pipe for combined evaporative cooling of computer room air-conditioning system
    Han, Zongwei
    Zhang, Yanqing
    Meng, Xin
    Liu, Qiankun
    Li, Weiliang
    Han, Yu
    Zhang, Yanhong
    [J]. ENERGY, 2016, 98 : 15 - 25
  • [9] Discussion on Application of Heat Pipe in Air-Conditioning
    Ji, Amin
    Lv, Xiyong
    Yin, Gang
    Li, Jie
    Qian, Jianfeng
    He, Li
    [J]. ADVANCED RESEARCH ON ELECTRONIC COMMERCE, WEB APPLICATION, AND COMMUNICATION, PT 1, 2011, 143 : 97 - 102
  • [10] Energy performance of air-conditioning systems using an indirect evaporative, cooling combined with a cooling/reheating treatment
    Cianfrini, Claudio
    Corcione, Massimo
    Habib, Emanuele
    Quintino, Alessandro
    [J]. ENERGY AND BUILDINGS, 2014, 69 : 490 - 497