Outcome of anatomic locking plate in extraarticular distal humeral shaft fractures

被引:17
|
作者
Jain, Deepak [1 ]
Goyal, Gurpreet S. [1 ]
Garg, Rajnish [1 ]
Mahindra, Pankaj [1 ]
Yamin, Mohammad [1 ]
Selhi, Harpal S. [1 ]
机构
[1] Dayanand Med Coll & Hosp, Dept Orthopaed, Ludhiana 141001, Punjab, India
关键词
Anatomic plate; distal humerus; extraarticular; humeral fracture; posterolateral plate; DIAPHYSEAL FRACTURES; INTERNAL-FIXATION; OSTEOSYNTHESIS; 3RD;
D O I
10.4103/0019-5413.197554
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Extraarticular fractures of distal humerus are challenging injuries to treat because of complex anatomy and fracture patterns. Functional bracing may not provide adequate stability in these injuries and operative treatment with intramedullary nails or conventional plates also has the limitation of inadequate fixation in the short distal fragment. The 3.5 mm precontoured single column locking plate (extraarticular distal humerus plate [EADHP]) has been introduced to overcome this problem. We evaluated the clinical and functional outcomes of treating these fractures with the EADHP. Materials and Methods: 26 patients with extraarticular fractures of distal humerus presenting within 3 weeks of injury between January 2012 and June 2015, were included in this prospective study. Open IIIB and IIIC fractures, nonunions, or those with a history of previous infection in the arm were excluded. Operative fixation was done using the EADHP in all the cases. The time for union, range of motion at shoulder and elbow and secondary procedures were recorded in followup. The shoulder and elbow function was assessed using the University of California Los Angeles (UCLA) shoulder scale and Mayo Elbow Performance Score (MEPS) respectively. Results: There were 21 males and 5 females with mean age of 37.3 years (range 18-72 years). Twenty two (84.6%) cases had complex fracture patterns (AO/OTA Type 12-B and C). The mean time to fracture union was 22.4 weeks (range 16-28 weeks). The mean followup time was 11.6 months, (range 4-24 months). Four patients (15.4%) had failure of cortical screws in the proximal fracture fragment, of which two required revision fixation with bone grafting. Another nonunion was seen following a surgical site infection, which healed after wound lavage and bone grafting. The MEPS (average: 96.1; range 80-100) was excellent in 81% cases (n = 21) and good in 19% cases (n = 5). UCLA score (average: 33.5; range 25-35) was good/excellent in 88.5% cases (n = 23) and fair in 11.5% cases (n = 3). Conclusion: EADHP is a reliable option in treating extraarticular distal humeral fractures as it provides stable fixation with an early return to function.
引用
收藏
页码:86 / 92
页数:7
相关论文
共 50 条
  • [1] Outcome of anatomic locking plate in extraarticular distal humeral shaft fractures
    Deepak Jain
    Gurpreet S. Goyal
    Rajnish Garg
    Pankaj Mahindra
    Mohammad Yamin
    Harpal S. Selhi
    Indian Journal of Orthopaedics, 2017, 51 : 86 - 92
  • [2] Distal medial tibial locking plate for fixation of extraarticular distal humeral fractures; an alternative choice for fixation
    Yorukoglu, Ali Cagdas
    Demirkan, Ahmet Fahir
    Buker, Nihal
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2018, 52 (04) : 294 - 298
  • [3] A simple technique for double plating of extraarticular distal humeral shaft fractures
    Sharaby, Mohamed
    Elhawary, Ahmed
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (06): : 708 - 713
  • [4] PLATE OSTEOSYNTHESIS OF DISTAL HUMERAL SHAFT FRACTURES
    Litvinov, I. I.
    Klyuchevsky, V. V.
    Ryzhkin, A. A.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2011, (01): : 117 - 120
  • [5] Surgical outcome of humeral shaft fractures with proximal extension treated with long locking plate
    Agnello, Luciano
    Moerenhout, Kevin
    Stettler, Melanie
    Djahangiri, Ali
    SWISS MEDICAL WEEKLY, 2012, 142 : S37 - S38
  • [6] Outcome after long locking plate osteosynthesis of complex humeral shaft fractures.
    Grieb, Maximilian
    Zdravkovic, Vilijam
    Spross, Christian
    Jost, Bernhard
    SWISS MEDICAL WEEKLY, 2019, 149 : 45S - 45S
  • [7] Intramedullary nailing for humeral shaft fractures: Is distal locking necessary?
    Egrise, Francois
    Clowez, Gilles
    Recanatesi, Nicolas
    Tabutin, Jacques
    Borge, Paul Emile
    Gastaud, Olivier
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (05)
  • [8] Shaft and distal humeral fractures
    Culemann, Ulf
    TRAUMA UND BERUFSKRANKHEIT, 2016, 18 : S468 - S473
  • [9] Anterior minimally invasive plating osteosynthesis using reversed proximal humeral internal locking system plate for distal humeral shaft fractures
    Jitprapaikulsarn, Surasak
    Neti, Nutdanai
    Thremthakanpon, Witoon
    Gromprasit, Arthit
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (08): : 1515 - 1521
  • [10] Anterior minimally invasive plating osteosynthesis using reversed proximal humeral internal locking system plate for distal humeral shaft fractures
    Surasak Jitprapaikulsarn
    Nutdanai Neti
    Witoon Thremthakanpon
    Arthit Gromprasit
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 1515 - 1521