A simple fabrication method for tapered capillary tip and its applications in high-speed CE and ESI-MS

被引:7
|
作者
Cheng, Yong-Qiang [1 ,2 ]
Su, Yuan [1 ]
Fang, Xiao-Xia [1 ]
Pan, Jian-Zhang [1 ]
Fang, Qun [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
[2] Shandong Acad Sci, Inst Oceanog Instrumentat, Qingdao, Peoples R China
关键词
ESI-MS; High-speed CE; Tapered capillary; IONIZATION MASS-SPECTROMETRY; SHEATHLESS ELECTROSPRAY EMITTERS; ELECTROPHORESIS; INTERFACE; MICROINJECTION; PERFORMANCE; SKIN;
D O I
10.1002/elps.201300631
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fabrication of capillaries with tapered tips is an important technique that is required in many analytical chemistry areas, such as ESI-MS, CE, electrochemical analysis, and microinjection. This paper describes a simple and effective grinding-based fabrication method for capillaries with tapered tips. A novel grinding mode utilizing the combination of rotation and precession of an elastic capillary was developed, which significantly improved the controllability to the grinding process as well as the capillary tip shape. The capillary was fabricated by fixing it in an electric drill installed perpendicularly, and grind the capillary tip rotated around its own axis as well as the drill axis on sandpapers. Compared with conventional fabrication techniques for capillary tips, the present method is easy to control the capillary tip shape in routine laboratories without the requirement of expensive equipments or poisonous reagent (e.g. hydrofluoric acid (HF) solution). Various capillaries with different tip diameters and tip taper angles could be fabricated using the present method with good controllability and reproducibility. These capillaries were applied in high-speed CE and ESI-MS analysis to demonstrate the feasibility and potential of this fabrication method.
引用
收藏
页码:1484 / 1488
页数:5
相关论文
共 12 条
  • [1] Simple and high sample throughput LC/ESI-MS/MS method for bioequivalence study of prazosin, a drug with risk of orthostatic hypotension
    Loh, Gabriel Onn Kit
    Wong, Emily Yii Ling
    Tan, Yvonne Tze Fung
    Wee, Hong Chin
    Ng, Ru Shing
    Syed, Haroon Khalid
    Peh, Kok Khiang
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2022, 48 (09) : 470 - 479
  • [2] Preparative metabolite isolation of Tropaeolum majus L. by high-speed countercurrent chromatography based on off-line continuous ESI-MS/MS injection
    Jerz, G.
    Schmalfuss, E.
    Kleinwaechter, M.
    Winterhalter, P.
    Selmar, D.
    [J]. PLANTA MEDICA, 2013, 79 (13) : 1178 - 1178
  • [3] METHOD OF HIGH-SPEED MEASUREMENT OF SURFACE-ROUGHNESS AND ITS APPLICATIONS
    SATO, H
    MITSUI, K
    [J]. JOURNAL OF JAPAN SOCIETY OF LUBRICATION ENGINEERS, 1976, 21 (11): : 733 - 739
  • [4] A PREDICTION METHOD USING HIGH-SPEED ANALOG COMPUTERS AND ITS APPLICATIONS
    GULKO, FB
    KOGAN, BY
    LERNER, AY
    MIKHAILO.NN
    NOVOSELT.ZA
    [J]. AUTOMATION AND REMOTE CONTROL, 1965, 25 (06) : 803 - &
  • [5] Development and Validation of Highly Sensitive LC–ESI-MS/MS Method for Bortezomib and Its Applications for Plasma Levels and Drug Content of Branded and Generic Formulations in India
    Lavisha Goel
    Ujjalkumar Subhash Das
    Pooja Gupta
    Thirumurthy Velpandian
    Lalit Kumar
    Archana Singh
    Kalpana Luthra
    Yogendra Kumar Gupta
    [J]. Chromatographia, 2022, 85 : 127 - 135
  • [6] Caustics method combined with laser & digital high-speed camera and its applications
    [J]. Yang, L.-Y. (yangly@cumtb.edu.cn), 2013, China University of Mining and Technology (42):
  • [7] Separation and identification of water-soluble salvianolic acids from Salvia miltiorrhiza Bunge by high-speed counter-current chromatography and ESI-MS analysis
    Chen, JH
    Wang, FM
    Lee, FSC
    Wang, XR
    Xie, MY
    [J]. TALANTA, 2006, 69 (01) : 172 - 179
  • [8] A simple and efficient frit preparation method for one-end tapered-fused silica-packed capillary columns in nano-LC-ESI MS
    Tan, Feng
    Chen, Shuo
    Zhang, Yangjun
    Cai, Yun
    Qian, Xiaohong
    [J]. PROTEOMICS, 2010, 10 (08) : 1724 - 1727
  • [9] Method development for the analysis of particle phase substituted methoxy phenols and aromatic acids from biomass burning using capillary electrophoresis/electro spray ionization mass spectrometry (CE/ESI-MS)
    Iinuma, Y
    Herrmann, H
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1018 (01) : 105 - 115
  • [10] The One-dimensional Unsteady Flow Prediction Method for Pressure Waves in High-Speed Subway and its Applications
    Zhou, Chaohui
    Mei, Yuangui
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, PTS 1-3, 2011, 94-96 : 1967 - 1970