Design and simulation of an infrared optical filter suitable for carbon dioxide and CO2 lasers

被引:0
|
作者
Abdelbagi, Abdelrazig Mohamed [1 ]
Kamal, Maha [2 ]
机构
[1] Shaqra Univ, Phys Dept, Sci Coll, Riyadh, Saudi Arabia
[2] Omdurman Islamic Univ, Phys Dept, Omdurman, Sudan
关键词
Carbon dioxide; Simulation; Spectroscopy; Infrared filter; CO2; laser; Semiconductor compound; LABORATORY SPECTRA; IR; CO2;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The main objective of this study was to assess the molecular simulation of the design of carbon dioxide (CO2) and to construct infrared optical filters for the transmission and absorption of the CO2 laser and the emission of gaseous CO2 radiation. Semiconductor compounds used to determine the wavelength of infrared transmission and absorption infrared radiation (IR) to produce an IR filter for laser production and gas emission using the Fourier Transform infrared spectrometer (FT-RI) for research purposes. Carbon dioxide molecule simulation has been used based on Hyper 6 simulation programme in potential energy, and kinetic energy, which measures the infrared radiation spectrum. Infrared filters are constructed from the compounds of a semiconductor of Zinc Sulfide supplied (ZnS), Aluminum Oxide (Al2O3), Magnesium Oxide (MgO), Lead (II) Sulfide (PbS), and Potassium Chloride (KCl). The data used for evaluation of the optical elements in the IR region based on the transmission and absorption of radiation intensity effective for wavelength detection. The assessment of the detection is indicating transmission and absorption of the wavelengths of CO2 laser and CO2 gas molecule under investigation. This study has identified the approach of the result of transmission and absorption of the peak intensities of 10.6, 2.7, 4.3 and 15 mu m of CO2 laser and gas radiation emission of the filters in the IR region. The findings of this study have a number of important applications in the IR radiation region.
引用
收藏
页码:109 / 115
页数:7
相关论文
共 50 条
  • [2] Optical metrology for CO2 lasers
    Nowicki, Mike
    Zletklowicz, Chris
    Burstein, Neal L.
    Jeffers, William Q.
    Lasers & Optronics, 1993, 12 (08):
  • [3] Epilepsy Carbon dioxide (CO2)
    不详
    PROGRESS IN NEUROLOGY AND PSYCHIATRY, 2010, 14 (06) : 34 - 34
  • [4] Angiography with carbon dioxide (CO2)
    Back, MR
    Caridi, JG
    Hawkins, IF
    Seeger, JM
    SURGICAL CLINICS OF NORTH AMERICA, 1998, 78 (04) : 575 - +
  • [5] CARBON MONOXIDE FORMATION IN CO2 LASERS
    WIEGAND, WJ
    FOWLER, MC
    BENDA, JA
    APPLIED PHYSICS LETTERS, 1970, 16 (06) : 237 - &
  • [6] High resolution infrared spectroscopy of carbon dioxide clusters up to (CO2)13
    Oliaee, J. Norooz
    Dehghany, M.
    McKellar, A. R. W.
    Moazzen-Ahmadi, N.
    JOURNAL OF CHEMICAL PHYSICS, 2011, 135 (04):
  • [7] Design of Mid-infrared Negative Filter Against CO2 Radiation (Invited)
    Fu Xiuhua
    Zhang Tianxiang
    Xiong Shifu
    Lin Zhaowen
    Wang Ben
    ACTA PHOTONICA SINICA, 2022, 51 (09)
  • [8] Carbon dioxide (CO2) angiography in children
    V. M. Kriss
    Carol M. Cottrill
    John C. Gurley
    Pediatric Radiology, 1997, 27 : 807 - 810
  • [9] CONVERTING CARBON DIOXIDE (CO2) INTO FUEL
    Mahecic, Smiljan
    GRADEVINAR, 2009, 61 (06): : 605 - 606
  • [10] Lethal carbon dioxide (CO2) embolism?
    Meininger, D.
    ANAESTHESIST, 2008, 57 (08): : 823 - 824