Adhesive strength of autologous fibrin glue

被引:0
|
作者
Yoshida, H [1 ]
Hirozane, K [1 ]
Kamiya, A [1 ]
机构
[1] Yamaguchi Univ, Dept Pharm, Yamaguchi 7558505, Japan
关键词
fibrin glue; adhesive strength; fibrinogen; fibronectin; cryoprecipitate; autologous plasma;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
To establish an easy and rapid method for measuring the adhesive strength of fibrin glue and to clarify the factor(s) most affecting the strength, a study was made on the effect of the concentration of plasma components on the strength of cryoprecipitate (Cryo) prepared from a subject's own autologous plasma to be used as fibrin glue. The adhesive strength of the Cryo was measured with various supporting materials instead of animal skin using a tester of tension and compression. The results were as follows: (1) the strength of Cryo applied to ground flat glass (4 cm(2)) was significantly greater than that applied to clear glass, clear plastic, or smooth and hat wood chips; (2) the adhesive strength of Cryo depended on the concentration of thrombin with the optimal concentration being 50 units/ml; (3) the concentration of CaCl2 did not affect the adhesive strength of Cryo; (4) the adhesive reaction was dependent on the temperature and the adhesive strength more quickly reached a steady state at 37 degrees C than at lower temperature; (5) the adhesive strength was correlated well with the total concentration of fibrinogen and fibronectin. These results indicate that the adhesive strength of Cryo can be easily and quickly evaluated using a tester and ground glass with thrombin at 50 units/ml, and that the adhesive strength of Cryo can be predicted from the total concentration of fibrinogen and fibronectin.
引用
收藏
页码:313 / 317
页数:5
相关论文
共 50 条
  • [1] Adhesive strength of fibrin glue
    Yu, BG
    Kwon, LC
    Kim, YH
    Park, KD
    Han, K
    Jeong, SY
    23RD INTERNATIONAL SYMPOSIUM ON CONTROLLED RELEASE OF BIOACTIVE MATERIALS, 1996 PROCEEDINGS, 1996, : 799 - 800
  • [2] IMPORTANT FACTORS INFLUENCING THE STRENGTH OF AUTOLOGOUS FIBRIN GLUE - THE FIBRIN CONCENTRATION AND REACTION-TIME - COMPARISON OF STRENGTH WITH COMMERCIAL FIBRIN GLUE
    KJAERGARD, HK
    WEISFOGH, US
    EUROPEAN SURGICAL RESEARCH, 1994, 26 (05) : 273 - 276
  • [3] AUTOLOGOUS FIBRIN GLUE FOR TYMPANOPLASTY
    PARK, MS
    AMERICAN JOURNAL OF OTOLOGY, 1994, 15 (05): : 687 - 689
  • [4] INTRAOPERATIVE PROCUREMENT OF AUTOLOGOUS FIBRIN GLUE
    QUIGLEY, RL
    PERKINS, JA
    GOTTNER, RJ
    CURRAN, RD
    KUEHN, BE
    HOFF, WJ
    WALLOCK, ME
    ARENTZEN, CE
    ALEXANDER, JC
    ANNALS OF THORACIC SURGERY, 1993, 56 (02): : 387 - 389
  • [5] A Novel High-strength Autologous Fibrin Glue Augmented with Biocompatible Polymers
    Karmaker, Anindya
    Hasan, Mahmudul
    Ali, Shafayet
    Asif, Kazi Md
    Ahmed, Shoeb
    JOURNAL OF ADHESION, 2023, 99 (04): : 632 - 647
  • [6] Preparation and characterization of autologous fibrin glue
    Rock, G
    Neurath, D
    Harvey, M
    Freedman, M
    TRANSFUSION, 2003, 43 (09) : 5A - 5A
  • [7] AUTOLOGOUS FIBRIN TISSUE ADHESIVE
    SIEDENTOP, KH
    HARRIS, DM
    SANCHEZ, B
    LARYNGOSCOPE, 1985, 95 (09): : 1074 - 1076
  • [8] FIBRIN ADHESIVE TO GLUE ACHILLES-TENDON
    HAAS, F
    HAIBOCK, H
    REINDL, P
    ZENTRALBLATT FUR CHIRURGIE, 1987, 112 (02): : 99 - 104
  • [9] Measurement of the adhesive strength of glue
    Lanyon, CE
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1927, 19 (01): : 1191 - 1193
  • [10] AUTOLOGOUS FIBRIN GLUE (A NEW METHOD OF PREPARATION)
    ALTERBAUM, R
    WILLIAMS, L
    REQUENA, R
    LERNER, R
    SURGICAL FORUM, 1985, 36 : 544 - 546