Performances of a prototype for the ALICE Muon trigger at LHC

被引:5
|
作者
Arnaldi, R [1 ]
Baldit, A
Barret, V
Bastid, N
Blanchard, G
Chiavassa, E
Cortese, P
Crochet, P
Dellacasa, G
De Marco, N
Drancourt, C
Dupieux, P
Ferretti, A
Forestier, B
Insa, C
Jouve, E
Gallio, M
Genoux-Lubain, A
Lamoine, L
Manso, F
Mereu, P
Musso, A
Oppedisano, C
Piccotti, A
Poggio, F
Rosnet, R
Royer, L
Saturnini, P
Scalas, E
Scomparin, E
Sigaudo, F
Travaglia, G
Vercellin, E
Yermia, F
机构
[1] Univ Turin, Ist Nazl Fis Nucl, Dipartimento Fis Sperimentale, I-10125 Turin, Italy
[2] CNRS, LPC, F-63177 Clermont Ferrand, France
[3] Univ Clermont Ferrand, F-63177 Clermont Ferrand, France
[4] Univ Piemonte Orientale, Dipartimento Sci & Tecnol Avanzate, I-15100 Alessandria, Italy
[5] Univ Nantes, Subatech, CNRS, Ecole Mines, F-44070 Nantes 03, France
[6] Univ Clermont Ferrand, F-63177 Aubiere, France
[7] CNRS, LPC Clermont Ferrand, F-63177 Aubiere, France
[8] Ist Nazl Fis Nucl, Sez Torino, I-10125 Turin, Italy
[9] Univ Messina, Dipartimento Fis, I-98166 Messina, Italy
关键词
dimuon; heavy ion collision; resistive plate chamber; timing; trigger;
D O I
10.1109/TNS.2004.828621
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
ALICE, the experiment dedicated to the study of heavy ion collisions at LHC, will be equipped with a forward spectrometer to identify heavy quarkonium states from their decay into muons. The trigger system of the spectrometer consists of four planes of resistive plate chambers, front-end and fast-decision electronics. It is designed to reconstruct muon tracks in a large background environment and to provide a fast trigger signal to the spectrometer. We present results from the test of a trigger prototype that have been carried out with the moon beam of the CERN/SPS at the Gamma Irradiation Facility (GIF). The track finding efficiency as well as the robustness of the system to the uncorrelated background induced on the detector by the GIF source are discussed. Special emphasis is put on timing aspects which are crucial at LHC. A self-consistent method for timing optimization and monitoring is proposed. The findings, although specific to ALICE, are relevant to any muon trigger system operating at LHC.
引用
收藏
页码:375 / 382
页数:8
相关论文
共 50 条
  • [1] Performances of a prototype for the ALICE muon trigger at LHC
    Forestier, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 533 (1-2): : 22 - 26
  • [2] The trigger system of the ALICE muon spectrometer at the LHC
    Blanc, A.
    Dupieux, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 301 - 303
  • [3] Commissioning of the ALICE muon spectrometer trigger at LHC
    Ahn, S.
    Arnaldi, R.
    Baek, Y.
    Baldit, A.
    Barret, V.
    Bastid, N.
    Batigne, G.
    Beney, J. L.
    Berny, R.
    Bianchi, L.
    Blanc, A.
    Blanchard, G.
    Bossu, F.
    Chiavassa, E.
    Cortese, P.
    Crochet, P.
    Dellacasa, G.
    De Marco, N.
    Dupieux, P.
    Ferretti, A.
    Gagliardi, M.
    Gallio, M.
    Insa, C.
    Jouve, F.
    Lopez, X.
    Luparello, G.
    Monceau, L.
    Manso, F.
    Mereu, P.
    Musso, A.
    Oppedisano, C.
    Picotti, A.
    Renard, C.
    Rosnet, P.
    Roy, D.
    Royer, L.
    Saturnini, P.
    Scomparini, E.
    Stocco, D.
    Vercellin, E.
    Vulpescu, B.
    Zhang, X.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 661 : S41 - S44
  • [4] The trigger system of the muon spectrometer of the ALICE experiment at the LHC
    Bossu, F.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2011, 215 : 204 - 207
  • [5] Performance of the RPC-based ALICE muon trigger system at the LHC
    Bossu, F.
    Gagliardi, M.
    Marchisone, M.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [6] Performance of the ALICE muon trigger RPCs during LHC Run I
    Fontana, M.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [7] Performance of the ALICE muon trigger system in pp and Pb-Pb collisions at the LHC
    Fronze, G. G.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [8] The ALICE forward muon spectrometer at the LHC
    Morsch, A
    NUCLEAR PHYSICS A, 1998, 638 (1-2) : 571C - 574C
  • [9] Muon Forward Tracker in ALICE at the LHC
    Krupova, Diana
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [10] Trigger detectors for the ALICE muon spectrometer
    Piccotti, A.
    Arnaldi, R.
    Chiavassa, E.
    Cortese, P.
    Dellacasa, G.
    De Marco, N.
    Ferretti, A.
    Gagliardi, M.
    Gallio, M.
    Gemme, R.
    Luparello, G.
    Mereu, P.
    Musso, A.
    Oppedisano, C.
    Poggio, F.
    Scomparin, E.
    Stocco, D.
    Vercellin, E.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2493 - +