Corneal lathing using the excimer laser and a computer-controlled positioning system

被引:0
|
作者
Biowski, R
Homolka, P
Barisani-Asenbauer, T
Baumgartner, I
Husinsky, W
Kaminski, S
Lametschwandtner, A
Muss, W
Grabner, G
机构
[1] Univ Vienna, Allgemeins Krankenhaus, Dept Ophthalmol, Sch Med, A-1090 Vienna, Austria
[2] Vienna Univ Technol, Dept Biomed Engn & Phys, A-1060 Vienna, Austria
[3] Vienna Univ Technol, Inst Allgemeine Phys, A-1060 Vienna, Austria
[4] Salzburg Univ, Inst Zool, A-5020 Salzburg, Austria
[5] St Johanns Spital, Inst Pathol, Salzburg, Austria
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To present the excimer laser corneal shaping system (ELCS-S), an add-on device to the Keratom, a commercially available 193-nm excimer laser built by Schwind. METHODS: The system is designed for the preparation of donor corneas under sterile conditions using the ultraviolet laser to offer greatest possible flexibility. Lenticules for planolamellar grafting and refractive epikeratoplasty, as well as donor buttons for penetrating keratoplasty can be computer-designed by the surgeon or technician and lathed with the system. RESULTS: Using the excimer laser corneal shaping system (ELCS-S) on human donor corneas, the central surface of the epikeratoplasty lenticule exhibited only narrow, flat concentric notches corresponding to the single lathing steps. Transmission electron microscopy revealed a damage zone of less than 0.3 mu m in close approximation to the treated surface. The final thickness revealed a difference of less than +/-53 mu m from the intended, initially programmed value. Ultrastructural studies showed the perpendicular stromal surface of the penetrating keratoplasty buttons to be smooth with minimal protrusion of Descemet's membrane. Endothelial injury was observed in a zone averaging between 40 and 100 mu m adjacent to the cutting edge only. CONCLUSION: The excimer laser corneal shaping system (ELCS-S) allows a computer-controlled, surgeon-designed, sterile preparation of lamellar and penetrating corneal grafts with the use of the excimer laser. This could offer significant advantages in comparison to presently available systems for lamellar dissection and trephination.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 50 条
  • [1] An improved excimer laser technique for lathing corneal transplants
    Biowski, RK
    Homolka, P
    Baumgartner, I
    Husinsky, WR
    Kaminski, SL
    Lametschwandtner, A
    Muss, W
    Grabner, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4017 - 4017
  • [2] COMPUTER-CONTROLLED TARGET-POSITIONING SYSTEM
    BRENDLE, M
    STEIDLE, G
    NUCLEAR INSTRUMENTS & METHODS, 1975, 126 (01): : 93 - 98
  • [3] POSTERIOR MYOPIC KERATOMILEUSIS BY EXCIMER LASER LATHING OF FRESH CORNEAL LAMELLAE
    GANEM, SP
    GROSS, M
    LOISANCE, D
    GALLE, P
    ROSOLEN, S
    MONDON, H
    ARONROSA, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 800 - 800
  • [4] Computer-controlled nanosecond laser system
    Thomas, Michael D.
    Hug, Gordon L.
    Computers & Chemistry, 22 (06): : 491 - 498
  • [5] A computer-controlled nanosecond laser system
    Thomas, MD
    Hug, GL
    COMPUTERS & CHEMISTRY, 1998, 22 (06): : 491 - 498
  • [6] Implantable computer-controlled adaptive multielectrode positioning system
    Ferrea, E.
    Suriya-Arunroj, L.
    Hoehl, D.
    Thomas, U.
    Gail, A.
    JOURNAL OF NEUROPHYSIOLOGY, 2018, 119 (04) : 1471 - 1484
  • [8] COMPUTER-CONTROLLED LASER ANIMATION
    HUCKINS, L
    LASER FOCUS WORLD, 1989, 25 (02): : 44 - 44
  • [9] COMPUTER-CONTROLLED LASER INTERFEROMETER
    HEELEY, DW
    BEHAVIOR RESEARCH METHODS & INSTRUMENTATION, 1979, 11 (05): : 523 - 525
  • [10] A videogrammetric system for computer-controlled non-invasive patient positioning
    Lappe, C
    Helfert, S
    Braun, M
    Pastyr, O
    Sturm, V
    Schlegel, W
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 168 - 171