An in vitro comparison of possibly bioactive titanium implant surfaces

被引:27
|
作者
Goransson, A. [1 ,2 ]
Arvidsson, A. [1 ]
Currie, F. [3 ]
Franke-Stenport, V. [1 ,2 ]
Kjellin, P. [3 ]
Mustafa, K. [4 ]
Sul, Y. T. [1 ]
Wennerberg, A. [1 ,2 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Dept Biomat, Inst Surg Sci, Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Dept Prosthet Dent Dent Mat Sci, Gothenburg, Sweden
[3] Chalmers Univ Technol, Dept Appl Surface Chem, S-41296 Gothenburg, Sweden
[4] Univ Bergen, Fac Dent, Ctr Clin Dent Res, Bergen, Norway
关键词
SBF; in vitro; surface modification; titanium implant; bioactivity; HEAT-TREATED TITANIUM; BONE RESPONSE; ELECTROPOLISHED IMPLANTS; OXIDIZED IMPLANTS; TISSUE-RESPONSE; OXIDE FILMS; THIN-FILMS; ALKALI; BEHAVIOR; CA;
D O I
10.1002/jbm.a.31911
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of the study was to compare Ca and P formation (CaP) and subsequent bone cell response of a blasted and four different possibly bioactive commercially pure (cp) titanium surfaces; 1. Fluoride etched (Fluoride), 2. Alkali-heat treated (AH), 3. Magnesium ion incorporated anodized (TiMgO), and 4. Nano HA coated and heat treated (nano HA) in vitro. Furthermore, to evaluate the significance of the SBF formed CaP coat on bone cell response. The surfaces were characterized by Optical Interferometry, Scanning Electron Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS). CaP formation was evaluated after 12, 24 and 72 h in simulated body fluid (SBF). Primary human mandibular osteoblast-like cells were cultured on the various surfaces subjected to SBF for 72 h. Cellular attachment, differentiation (osteocalcin) and protein production (TGF-beta(1)) was evaluated after 3 h and 10 days respectively. Despite different morphological appearances, the roughness of the differently modified surfaces was similar. The possibly bioactive surfaces gave rise to an earlier CaP formation than the blasted surface, however, after 72 h the blasted surface demonstrated increased CaP formation compared to the possibly bioactive surfaces. Subsequent bone cell attachment was correlated to neither surface roughness nor the amount of formed CaP after SBF treatment. In contrast, osteocalcin and TGF-beta(1) production were largely correlated to the amount of CaP formed on the surfaces. However, bone response (cell attachment, osteocalcin and TGF-F production) on the blasted controls were similar or increased compared to the SBF treated fluoridated, AH and TiMgO surface. (c) 2008 Wiley Periodicals, Inc. J Biomed Mater Res 88A: 1037-1047, 2009
引用
收藏
页码:1037 / 1047
页数:11
相关论文
共 50 条
  • [1] Antibacterial and bioactive coatings on titanium implant surfaces
    Aranya, Anupama Kulkarni
    Pushalkar, Smruti
    Zhao, Minglei
    LeGeros, Racquel Z.
    Zhang, Yu
    Saxena, Deepak
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2017, 105 (08) : 2218 - 2227
  • [2] IN VITRO ANALYSIS OF THE BONE ONGROWTH AT BIOACTIVE IMPLANT SURFACES
    Lochner, K.
    Erdmann, C.
    Luedtke, B.
    Hansmann, D.
    Fulda, G.
    Neumann, H.
    Mittelmeier, W.
    Bader, R.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (07): : 610 - 610
  • [3] In Vitro Biofilm Formation on Titanium and Zirconia Implant Surfaces
    Roehling, Stefan
    Astasov-Frauenhoffer, Monika
    Hauser-Gerspach, Irmgard
    Braissant, Olivier
    Woelfler, Henriette
    Waltimo, Tuomas
    Kniha, Heinz
    Gahlert, Michael
    JOURNAL OF PERIODONTOLOGY, 2017, 88 (03) : 298 - 307
  • [4] Microgrooves and Microrugosities in Titanium Implant Surfaces: An In Vitro and In Vivo Evaluation
    Gehrke, Sergio Alexandre
    Cavalcanti de Lima, Jose Henrique
    Rodriguez, Fernando
    Luis Calvo-Guirado, Jose
    Aramburu Junior, Jaime
    Perez-Diaz, Leticia
    Mazon, Patricia
    Manuel Aragoneses, Juan
    De Aza, Piedad N.
    MATERIALS, 2019, 12 (08)
  • [5] Bioactive titanium implant surfaces with bacterial inhibition and osteoblast function enhancement properties
    Shi, Z.L.
    Chua, P.H.
    Neoh, Koon Gee
    Kang, E.T.
    Wang, W.
    International Journal of Artificial Organs, 2008, 31 (09): : 777 - 785
  • [6] Bioactive titanium implant surfaces with bacterial inhibition and osteoblast function enhancement properties
    Shi, Z. L.
    Chua, P. H.
    Neoh, K. G.
    Kang, E. T.
    Wang, W.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (09): : 777 - 785
  • [7] Biofilms Developed on Dental Implant Titanium Surfaces with Different Roughness: Comparison Between In Vitro and In Vivo Studies
    Bevilacqua, Lorenzo
    Milan, Annalisa
    Del Lupo, Veronica
    Maglione, Michele
    Dolzani, Lucilla
    CURRENT MICROBIOLOGY, 2018, 75 (06) : 766 - 772
  • [8] Biofilms Developed on Dental Implant Titanium Surfaces with Different Roughness: Comparison Between In Vitro and In Vivo Studies
    Lorenzo Bevilacqua
    Annalisa Milan
    Veronica Del Lupo
    Michele Maglione
    Lucilla Dolzani
    Current Microbiology, 2018, 75 : 766 - 772
  • [9] In vivo and in vitro biofilm formation on two different titanium implant surfaces
    Buergers, Ralf
    Gerlach, Till
    Hahnel, Sebastian
    Schwarz, Frank
    Handel, Gerhard
    Gosau, Martin
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) : 156 - 164
  • [10] The role of bacterial corrosion on recolonization of titanium implant surfaces: An in vitro study
    Weller, Julia
    Vasudevan, Praveen
    Kreikemeyer, Bernd
    Ekat, Katharina
    Jackszis, Mario
    Springer, Armin
    Chatzivasileiou, Kyriaki
    Lang, Hermann
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (05) : 664 - 675