Enhanced 3D paper-based devices with a personal glucose meter for highly sensitive and portable biosensing of silver ion

被引:29
|
作者
Xiao, Wencheng [1 ]
Gao, Yiming [1 ]
Zhang, Yun [1 ]
Li, Jiao [1 ]
Liu, Zhaoying [1 ]
Nie, Jinfang [1 ]
Li, Jianping [1 ]
机构
[1] Guilin Univ Technol, Coll Chem & Bioengn, Guilin 541004, Peoples R China
来源
基金
美国国家科学基金会;
关键词
Paper-based microfluidics; Signal amplification; Point-of-care biosensor; Glucometer; Ag+; COLORIMETRIC DETECTION; SIGNAL AMPLIFICATION; MICROFLUIDIC DEVICES; GOLD NANOPARTICLES; HEAVY-METAL; AG+; SENSOR; EXTRACTION; FACILE; STRIP;
D O I
10.1016/j.bios.2019.05.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A variety of routine methods are available for the detection of silver (I) (Ag+) ions, but most of them rely on expensive, sophisticated and desktop instruments. Herein, a low-cost, instrument-free and portable Ag+ biosensor was described by initially designing a new class of 3D origami microfluidic paper-based analytical devices (mu PADs) into each of which one piece of reagent-loaded nanoporous membrane was integrated. It combines analyte-triggered self-growing of silver nanoparticles to block the membranes pores in situ for rapid yet efficient signal amplification with a handheld personal glucose meter for a portable and sensitive quantitative readout based on the biocatalytic reactions between the glucose oxidase and glucose. Its utility is well demonstrated with the specific detection of the analyte with a limit of detection as low as similar to 58.1 pM (3 sigma), which makes this new biosensing method one of the most sensitive Ag+ assays in comparison with many other typical methods recently reported. Moreover, the satisfactory recovery of analyzing several types of real water examples, i.e., tap water, drinking water, pond water and soil water, additionally validates its feasibility for practical applications.
引用
收藏
页码:154 / 160
页数:7
相关论文
共 50 条
  • [1] Highly sensitive and portable mercury(II) ion sensor using personal glucose meter
    Xu Xue-tao
    Liang Kai-yi
    Zeng Jia-ying
    ANALYTICAL METHODS, 2015, 7 (01) : 81 - 85
  • [2] 3D Printed Paper-Based Microfluidic Analytical Devices
    He, Yong
    Gao, Qing
    Wu, Wen-Bin
    Nie, Jing
    Fu, Jian-Zhong
    MICROMACHINES, 2016, 7 (07):
  • [3] 3D microfluidic paper-based analytical devices for colorimetric bioassays
    Neris, Natalia
    Wong, Alyssa
    Fernandez, Alyssa
    Gomez, Frank
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [4] 3D Multilayered paper- and thread/paper-based microfluidic devices for bioassays
    Neris, Natalia M.
    Guevara, Ricardo D.
    Gonzalez, Ariana
    Gomez, Frank A.
    ELECTROPHORESIS, 2019, 40 (02) : 296 - 303
  • [5] Paper-based microfluidic devices based on 3D network polymer hydrogel for the determination of glucose in human whole blood
    He, Rong-Yu
    Tseng, Hsin-Yi
    Lee, Hsia-An
    Liu, Yu-Ci
    Koshevoy, Igor O.
    Pan, Sheng-Wei
    Ho, Mei-Lin
    RSC ADVANCES, 2019, 9 (56) : 32367 - 32374
  • [6] Applications of 3D Printing in Paper-Based Devices for Biochemical and Environmental Analyses
    Thang, Tran Quoc
    Kim, Joohoon
    CHEMOSENSORS, 2025, 13 (03)
  • [7] Highly sensitive, colorimetric, paper-based devices for the dual detection of nitrate and nitrite
    Mako, Teresa
    Racicot, Joanie
    Levenson, Adelaide
    Levine, Mindy
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [8] Smartphone Coupled with a Paper-Based Colorimetric Device for Sensitive and Portable Mercury Ion Sensing
    Firdaus, M. Lutfi
    Aprian, Angga
    Meileza, Nessi
    Hitsmi, Marti
    Elvia, Rina
    Rahmidar, Lena
    Khaydarov, Renat
    CHEMOSENSORS, 2019, 7 (02)
  • [9] Paper-based Portable Gold Nanoclusters Devices for Visual Detection of Mercury(II) Ion
    Zhang Guo
    Feng Jian-Jun
    Chai Rui-Tao
    Zhu Wei-Huang
    Kang Qian-Wen
    Li Hui
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (04) : 583 - 590
  • [10] Highly sensitive detection of mercury ion based on T-rich DNA machine using portable glucose meter
    Huang, Shan
    Wang, Wenjing
    Cheng, Fangfang
    Yao, Huiqin
    Zhu, Jun-Jie
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 242 : 347 - 354